Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants.

Standard

Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants. / Schiffmann, Holger; Erdlenbruch, Bernhard; Singer, Dominique; Singer, Sybille; Herting, Egbert; Hoeft, Andreas; Buhre, Wolfgang.

In: J CARDIOTHOR VASC AN, Vol. 16, No. 5, 5, 2002, p. 592-597.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{266fcc2cfee34b34a1ca1d78349374cf,
title = "Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants.",
abstract = "OBJECTIVE: To assess cardiac output, intrathoracic blood volume, global end-diastolic volume, and extravascular lung water in critically ill neonates and small infants using transpulmonary indicator dilution. DESIGN: Prospective, observational, clinical study. SETTING: Pediatric intensive care unit in a university hospital. PARTICIPANTS: Critically ill neonates and small infants suffering from severe heart failure, respiratory failure, or sepsis (n = 10). INTERVENTIONS: A total of 194 transpulmonary indicator dilution measurements were done. Global end-diastolic volume, intrathoracic blood volume, and stroke volume were measured and compared with standard hemodynamic parameters during the clinical course and before and after volume loading (16 +/- 3.7 mL/kg of 10% albumin solution) in 8 of 10 patients. MEASUREMENTS AND MAIN RESULTS: A positive correlation was found for stroke volume index versus global end-diastolic volume (r = 0.76, p <0.001) and intrathoracic blood volume (r = 0.56, p <0.001). In contrast, no correlation was observed for stroke volume index versus central venous pressure. Volume loading resulted in significant increases in stroke volume index (p <0.01), global end-diastolic volume (p <0.01), and intrathoracic blood volume (p <0.01); whereas central venous pressure, heart rate, mean arterial pressure, and extravascular lung water remained unchanged. CONCLUSION: Transpulmonary indicator dilution enables measurement of cardiac output and intravascular volume status in critically ill neonates and infants at the bedside. The effects of volume loading on cardiac preload and effective change in stroke volume can be monitored by this technique, whereas central venous pressure was not indicative of changes in intravascular volume status.",
author = "Holger Schiffmann and Bernhard Erdlenbruch and Dominique Singer and Sybille Singer and Egbert Herting and Andreas Hoeft and Wolfgang Buhre",
year = "2002",
language = "Deutsch",
volume = "16",
pages = "592--597",
journal = "J CARDIOTHOR VASC AN",
issn = "1053-0770",
publisher = "W.B. Saunders Ltd",
number = "5",

}

RIS

TY - JOUR

T1 - Assessment of cardiac output, intravascular volume status, and extravascular lung water by transpulmonary indicator dilution in critically ill neonates and infants.

AU - Schiffmann, Holger

AU - Erdlenbruch, Bernhard

AU - Singer, Dominique

AU - Singer, Sybille

AU - Herting, Egbert

AU - Hoeft, Andreas

AU - Buhre, Wolfgang

PY - 2002

Y1 - 2002

N2 - OBJECTIVE: To assess cardiac output, intrathoracic blood volume, global end-diastolic volume, and extravascular lung water in critically ill neonates and small infants using transpulmonary indicator dilution. DESIGN: Prospective, observational, clinical study. SETTING: Pediatric intensive care unit in a university hospital. PARTICIPANTS: Critically ill neonates and small infants suffering from severe heart failure, respiratory failure, or sepsis (n = 10). INTERVENTIONS: A total of 194 transpulmonary indicator dilution measurements were done. Global end-diastolic volume, intrathoracic blood volume, and stroke volume were measured and compared with standard hemodynamic parameters during the clinical course and before and after volume loading (16 +/- 3.7 mL/kg of 10% albumin solution) in 8 of 10 patients. MEASUREMENTS AND MAIN RESULTS: A positive correlation was found for stroke volume index versus global end-diastolic volume (r = 0.76, p <0.001) and intrathoracic blood volume (r = 0.56, p <0.001). In contrast, no correlation was observed for stroke volume index versus central venous pressure. Volume loading resulted in significant increases in stroke volume index (p <0.01), global end-diastolic volume (p <0.01), and intrathoracic blood volume (p <0.01); whereas central venous pressure, heart rate, mean arterial pressure, and extravascular lung water remained unchanged. CONCLUSION: Transpulmonary indicator dilution enables measurement of cardiac output and intravascular volume status in critically ill neonates and infants at the bedside. The effects of volume loading on cardiac preload and effective change in stroke volume can be monitored by this technique, whereas central venous pressure was not indicative of changes in intravascular volume status.

AB - OBJECTIVE: To assess cardiac output, intrathoracic blood volume, global end-diastolic volume, and extravascular lung water in critically ill neonates and small infants using transpulmonary indicator dilution. DESIGN: Prospective, observational, clinical study. SETTING: Pediatric intensive care unit in a university hospital. PARTICIPANTS: Critically ill neonates and small infants suffering from severe heart failure, respiratory failure, or sepsis (n = 10). INTERVENTIONS: A total of 194 transpulmonary indicator dilution measurements were done. Global end-diastolic volume, intrathoracic blood volume, and stroke volume were measured and compared with standard hemodynamic parameters during the clinical course and before and after volume loading (16 +/- 3.7 mL/kg of 10% albumin solution) in 8 of 10 patients. MEASUREMENTS AND MAIN RESULTS: A positive correlation was found for stroke volume index versus global end-diastolic volume (r = 0.76, p <0.001) and intrathoracic blood volume (r = 0.56, p <0.001). In contrast, no correlation was observed for stroke volume index versus central venous pressure. Volume loading resulted in significant increases in stroke volume index (p <0.01), global end-diastolic volume (p <0.01), and intrathoracic blood volume (p <0.01); whereas central venous pressure, heart rate, mean arterial pressure, and extravascular lung water remained unchanged. CONCLUSION: Transpulmonary indicator dilution enables measurement of cardiac output and intravascular volume status in critically ill neonates and infants at the bedside. The effects of volume loading on cardiac preload and effective change in stroke volume can be monitored by this technique, whereas central venous pressure was not indicative of changes in intravascular volume status.

M3 - SCORING: Zeitschriftenaufsatz

VL - 16

SP - 592

EP - 597

JO - J CARDIOTHOR VASC AN

JF - J CARDIOTHOR VASC AN

SN - 1053-0770

IS - 5

M1 - 5

ER -