Antibody response to Shiga toxins Stx2 and Stx1 in children with enteropathic hemolytic-uremic syndrome.
Standard
Antibody response to Shiga toxins Stx2 and Stx1 in children with enteropathic hemolytic-uremic syndrome. / Ludwig, K; Karmali, M A; Sarkim, V; Bobrowski, C; Petric, M; Karch, H; Müller-Wiefel, Dirk E.
In: J CLIN MICROBIOL, Vol. 39, No. 6, 6, 2001, p. 2272-2279.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Antibody response to Shiga toxins Stx2 and Stx1 in children with enteropathic hemolytic-uremic syndrome.
AU - Ludwig, K
AU - Karmali, M A
AU - Sarkim, V
AU - Bobrowski, C
AU - Petric, M
AU - Karch, H
AU - Müller-Wiefel, Dirk E.
PY - 2001
Y1 - 2001
N2 - A Western blot (immunoblot) assay (WBA) for the detection of immunoglobulin G antibodies to Shiga toxins Stx2 and Stx1 in sera from 110 patients with enteropathic hemolytic-uremic syndrome (53 culture confirmed to have Shiga toxin-producing Escherichia coli [STEC] infection) and 110 age-matched controls was established by using a chemiluminescence detection system. Thirty-nine (74%) of the 53 culture-confirmed cases were infections with STEC serotype O157, and 14 (26%) were associated with infection by other STEC serotypes. The frequency of an anti-Stx2 response following infection by a Stx2-producing strain (34 of 48 cases; 71%) was higher than that of an anti-Stx1 response following Stx1-producing STEC infection (4 of 10). Furthermore, the frequency of an anti-Stx2 response in 110 control sera (10%) was significantly higher than the frequency of an anti-Stx1 response (1.8%) (P = 0.0325). For STEC O157 culture-confirmed cases WBA for toxin detection had a diagnostic sensitivity of 71% and a specificity of 90%. Because of its high specificity the assay might be a helpful tool for diagnosing suspected STEC infection when tests of stool samples or serological tests against various lipopolysaccharide antigens are negative. Furthermore, the prevalence of anti-Stx antibodies in healthy controls probably reflects the population immunity to systemic Stx-associated disease. It can thus serve as a basis for comparing immunity levels in different populations and for considering future Stx toxoid immunization strategies.
AB - A Western blot (immunoblot) assay (WBA) for the detection of immunoglobulin G antibodies to Shiga toxins Stx2 and Stx1 in sera from 110 patients with enteropathic hemolytic-uremic syndrome (53 culture confirmed to have Shiga toxin-producing Escherichia coli [STEC] infection) and 110 age-matched controls was established by using a chemiluminescence detection system. Thirty-nine (74%) of the 53 culture-confirmed cases were infections with STEC serotype O157, and 14 (26%) were associated with infection by other STEC serotypes. The frequency of an anti-Stx2 response following infection by a Stx2-producing strain (34 of 48 cases; 71%) was higher than that of an anti-Stx1 response following Stx1-producing STEC infection (4 of 10). Furthermore, the frequency of an anti-Stx2 response in 110 control sera (10%) was significantly higher than the frequency of an anti-Stx1 response (1.8%) (P = 0.0325). For STEC O157 culture-confirmed cases WBA for toxin detection had a diagnostic sensitivity of 71% and a specificity of 90%. Because of its high specificity the assay might be a helpful tool for diagnosing suspected STEC infection when tests of stool samples or serological tests against various lipopolysaccharide antigens are negative. Furthermore, the prevalence of anti-Stx antibodies in healthy controls probably reflects the population immunity to systemic Stx-associated disease. It can thus serve as a basis for comparing immunity levels in different populations and for considering future Stx toxoid immunization strategies.
M3 - SCORING: Zeitschriftenaufsatz
VL - 39
SP - 2272
EP - 2279
JO - J CLIN MICROBIOL
JF - J CLIN MICROBIOL
SN - 0095-1137
IS - 6
M1 - 6
ER -