A new method to statistically describe microcatheter tip position in patient-specific aneurysm models

Standard

A new method to statistically describe microcatheter tip position in patient-specific aneurysm models. / Nawka, Marie Teresa; Buhk, Jan-Hendrik; Gellissen, Susanne; Sedlacik, Jan; Fiehler, Jens; Frölich, Andreas Maximilian.

In: J NEUROINTERV SURG, Vol. 11, No. 4, 04.2019, p. 425-430.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{eecfcd5669c44906bb544c1ca928e337,
title = "A new method to statistically describe microcatheter tip position in patient-specific aneurysm models",
abstract = "BACKGROUND AND PURPOSE: Evidence on how to select microcatheters to facilitate aneurysm catheterization during coil embolization is sparse. We developed a new method to define microcatheter tip location inside a patient-specific aneurysm model as a 3-dimensional probability map. We hypothesized that precision and accuracy of microcatheter tip positioning depend on catheter tip shape and aneurysmal geometry.MATERIALS AND METHODS: Under fluoroscopic guidance two to three operators introduced differently shaped microcatheters (straight, 45°, 90°) into eight aneurysm models targeting the anatomic center of the aneurysm. Each microcatheter position was recorded with flat-panel CT, and 3-dimensional probability maps of the microcatheter tip positions were generated. Maps were assessed with histogram analyses and compared between tip shapes, aneurysm locations and operators.RESULTS: Among a total of 530 microcatheter insertions, the precision (mean distance between catheter positions) and accuracy (mean distance to target position) were significantly higher for the 45° tip (1.10±0.64 mm, 3.81±1.41 mm, respectively) than for the 90° tip (1.27±0.57 mm, p=0.010; 4.21±1.60 mm p=0.014, respectively). Accuracy was significantly higher in posterior communicating artery aneurysms (3.38±1.20 mm) than in aneurysms of the internal carotid artery (4.56±1.54 mm, p<0.001).CONCLUSION: Our method can be used tostatistically describe statistically microcatheter behavior in patient-specific anatomy, which may improve the available evidence guiding microcatheter shape selection. Experience increases the ability to reach the intended position with a microcatheter (accuracy) that is also dependent on the aneurysm location, whereas catheter tip choice determines the variability of catheter tip placements versus each other (precision). Clinical validation is required.",
keywords = "Journal Article",
author = "Nawka, {Marie Teresa} and Jan-Hendrik Buhk and Susanne Gellissen and Jan Sedlacik and Jens Fiehler and Fr{\"o}lich, {Andreas Maximilian}",
note = "{\textcopyright} Author(s) (or their employer(s)) 2018. No commercial re-use. See rights and permissions. Published by BMJ.",
year = "2019",
month = apr,
doi = "10.1136/neurintsurg-2018-014259",
language = "English",
volume = "11",
pages = "425--430",
journal = "J NEUROINTERV SURG",
issn = "1759-8478",
publisher = "BMJ PUBLISHING GROUP",
number = "4",

}

RIS

TY - JOUR

T1 - A new method to statistically describe microcatheter tip position in patient-specific aneurysm models

AU - Nawka, Marie Teresa

AU - Buhk, Jan-Hendrik

AU - Gellissen, Susanne

AU - Sedlacik, Jan

AU - Fiehler, Jens

AU - Frölich, Andreas Maximilian

N1 - © Author(s) (or their employer(s)) 2018. No commercial re-use. See rights and permissions. Published by BMJ.

PY - 2019/4

Y1 - 2019/4

N2 - BACKGROUND AND PURPOSE: Evidence on how to select microcatheters to facilitate aneurysm catheterization during coil embolization is sparse. We developed a new method to define microcatheter tip location inside a patient-specific aneurysm model as a 3-dimensional probability map. We hypothesized that precision and accuracy of microcatheter tip positioning depend on catheter tip shape and aneurysmal geometry.MATERIALS AND METHODS: Under fluoroscopic guidance two to three operators introduced differently shaped microcatheters (straight, 45°, 90°) into eight aneurysm models targeting the anatomic center of the aneurysm. Each microcatheter position was recorded with flat-panel CT, and 3-dimensional probability maps of the microcatheter tip positions were generated. Maps were assessed with histogram analyses and compared between tip shapes, aneurysm locations and operators.RESULTS: Among a total of 530 microcatheter insertions, the precision (mean distance between catheter positions) and accuracy (mean distance to target position) were significantly higher for the 45° tip (1.10±0.64 mm, 3.81±1.41 mm, respectively) than for the 90° tip (1.27±0.57 mm, p=0.010; 4.21±1.60 mm p=0.014, respectively). Accuracy was significantly higher in posterior communicating artery aneurysms (3.38±1.20 mm) than in aneurysms of the internal carotid artery (4.56±1.54 mm, p<0.001).CONCLUSION: Our method can be used tostatistically describe statistically microcatheter behavior in patient-specific anatomy, which may improve the available evidence guiding microcatheter shape selection. Experience increases the ability to reach the intended position with a microcatheter (accuracy) that is also dependent on the aneurysm location, whereas catheter tip choice determines the variability of catheter tip placements versus each other (precision). Clinical validation is required.

AB - BACKGROUND AND PURPOSE: Evidence on how to select microcatheters to facilitate aneurysm catheterization during coil embolization is sparse. We developed a new method to define microcatheter tip location inside a patient-specific aneurysm model as a 3-dimensional probability map. We hypothesized that precision and accuracy of microcatheter tip positioning depend on catheter tip shape and aneurysmal geometry.MATERIALS AND METHODS: Under fluoroscopic guidance two to three operators introduced differently shaped microcatheters (straight, 45°, 90°) into eight aneurysm models targeting the anatomic center of the aneurysm. Each microcatheter position was recorded with flat-panel CT, and 3-dimensional probability maps of the microcatheter tip positions were generated. Maps were assessed with histogram analyses and compared between tip shapes, aneurysm locations and operators.RESULTS: Among a total of 530 microcatheter insertions, the precision (mean distance between catheter positions) and accuracy (mean distance to target position) were significantly higher for the 45° tip (1.10±0.64 mm, 3.81±1.41 mm, respectively) than for the 90° tip (1.27±0.57 mm, p=0.010; 4.21±1.60 mm p=0.014, respectively). Accuracy was significantly higher in posterior communicating artery aneurysms (3.38±1.20 mm) than in aneurysms of the internal carotid artery (4.56±1.54 mm, p<0.001).CONCLUSION: Our method can be used tostatistically describe statistically microcatheter behavior in patient-specific anatomy, which may improve the available evidence guiding microcatheter shape selection. Experience increases the ability to reach the intended position with a microcatheter (accuracy) that is also dependent on the aneurysm location, whereas catheter tip choice determines the variability of catheter tip placements versus each other (precision). Clinical validation is required.

KW - Journal Article

U2 - 10.1136/neurintsurg-2018-014259

DO - 10.1136/neurintsurg-2018-014259

M3 - SCORING: Journal article

C2 - 30327387

VL - 11

SP - 425

EP - 430

JO - J NEUROINTERV SURG

JF - J NEUROINTERV SURG

SN - 1759-8478

IS - 4

ER -