A comparison of arterial spin labeling and dynamic susceptibility perfusion imaging for resection control in glioblastoma surgery

Standard

A comparison of arterial spin labeling and dynamic susceptibility perfusion imaging for resection control in glioblastoma surgery. / Lindner, Thomas; Ahmeti, Hajrullah; Juhasz, Julia; Helle, Michael; Jansen, Olav; Synowitz, Michael; Ulmer, Stephan.

In: ONCOTARGET, Vol. 9, No. 26, 06.04.2018, p. 18570-18577.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

APA

Vancouver

Bibtex

@article{2f2d191a07a04a92b9567b46dd73c25a,
title = "A comparison of arterial spin labeling and dynamic susceptibility perfusion imaging for resection control in glioblastoma surgery",
abstract = "Resection control using magnetic resonance imaging during neurosurgical interventions increases confidence regarding the extent of tumor removal already during the procedure. In addition to morphological imaging, functional information such as perfusion might become an important marker of the presence and extent of residual tumor mass. The aim of this study was to implement arterial spin labeling (ASL) perfusion imaging as a noninvasive alternative to dynamic susceptibility contrast (DSC) perfusion imaging in patients suffering from intra-axial tumors for resection control already during surgery. The study included 15 patients suffering from glioblastoma multiforme in whom perfusion imaging using DSC and ASL was performed before, during, and after surgery. The data obtained from intraoperative scanning were analyzed by two readers blinded to any clinical information, and the presence of residual tumor mass was evaluated using a ranking scale. Similarity of results was analyzed using the intraclass correlation coefficient and Pearson's correlation coefficient. The results show that intraoperative ASL is as reliable as DSC when performing intraoperative perfusion imaging. According to the results of this study, intraoperative imaging using ASL represents an attractive alternative to contrast agent-based perfusion imaging.",
author = "Thomas Lindner and Hajrullah Ahmeti and Julia Juhasz and Michael Helle and Olav Jansen and Michael Synowitz and Stephan Ulmer",
year = "2018",
month = apr,
day = "6",
doi = "10.18632/oncotarget.24970",
language = "English",
volume = "9",
pages = "18570--18577",
journal = "ONCOTARGET",
issn = "1949-2553",
publisher = "IMPACT JOURNALS LLC",
number = "26",

}

RIS

TY - JOUR

T1 - A comparison of arterial spin labeling and dynamic susceptibility perfusion imaging for resection control in glioblastoma surgery

AU - Lindner, Thomas

AU - Ahmeti, Hajrullah

AU - Juhasz, Julia

AU - Helle, Michael

AU - Jansen, Olav

AU - Synowitz, Michael

AU - Ulmer, Stephan

PY - 2018/4/6

Y1 - 2018/4/6

N2 - Resection control using magnetic resonance imaging during neurosurgical interventions increases confidence regarding the extent of tumor removal already during the procedure. In addition to morphological imaging, functional information such as perfusion might become an important marker of the presence and extent of residual tumor mass. The aim of this study was to implement arterial spin labeling (ASL) perfusion imaging as a noninvasive alternative to dynamic susceptibility contrast (DSC) perfusion imaging in patients suffering from intra-axial tumors for resection control already during surgery. The study included 15 patients suffering from glioblastoma multiforme in whom perfusion imaging using DSC and ASL was performed before, during, and after surgery. The data obtained from intraoperative scanning were analyzed by two readers blinded to any clinical information, and the presence of residual tumor mass was evaluated using a ranking scale. Similarity of results was analyzed using the intraclass correlation coefficient and Pearson's correlation coefficient. The results show that intraoperative ASL is as reliable as DSC when performing intraoperative perfusion imaging. According to the results of this study, intraoperative imaging using ASL represents an attractive alternative to contrast agent-based perfusion imaging.

AB - Resection control using magnetic resonance imaging during neurosurgical interventions increases confidence regarding the extent of tumor removal already during the procedure. In addition to morphological imaging, functional information such as perfusion might become an important marker of the presence and extent of residual tumor mass. The aim of this study was to implement arterial spin labeling (ASL) perfusion imaging as a noninvasive alternative to dynamic susceptibility contrast (DSC) perfusion imaging in patients suffering from intra-axial tumors for resection control already during surgery. The study included 15 patients suffering from glioblastoma multiforme in whom perfusion imaging using DSC and ASL was performed before, during, and after surgery. The data obtained from intraoperative scanning were analyzed by two readers blinded to any clinical information, and the presence of residual tumor mass was evaluated using a ranking scale. Similarity of results was analyzed using the intraclass correlation coefficient and Pearson's correlation coefficient. The results show that intraoperative ASL is as reliable as DSC when performing intraoperative perfusion imaging. According to the results of this study, intraoperative imaging using ASL represents an attractive alternative to contrast agent-based perfusion imaging.

U2 - 10.18632/oncotarget.24970

DO - 10.18632/oncotarget.24970

M3 - SCORING: Journal article

C2 - 29719627

VL - 9

SP - 18570

EP - 18577

JO - ONCOTARGET

JF - ONCOTARGET

SN - 1949-2553

IS - 26

ER -