3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation.

Standard

3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation. / Frericks, Bernd B; Caldarone, Franco C; Nashan, Björn; Savellano, Dagmar Högemann; Stamm, Georg; Kirchhoff, Timm D; Shin, Hoen-Oh; Schenk, Andrea; Selle, Dirk; Spindler, Wolf; Klempnauer, Jürgen; Peitgen, Heinz-Otto; Galanski, Michael.

In: EUR RADIOL, Vol. 14, No. 2, 2, 2004, p. 326-333.

Research output: SCORING: Contribution to journalSCORING: Journal articleResearchpeer-review

Harvard

Frericks, BB, Caldarone, FC, Nashan, B, Savellano, DH, Stamm, G, Kirchhoff, TD, Shin, H-O, Schenk, A, Selle, D, Spindler, W, Klempnauer, J, Peitgen, H-O & Galanski, M 2004, '3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation.', EUR RADIOL, vol. 14, no. 2, 2, pp. 326-333. <http://www.ncbi.nlm.nih.gov/pubmed/14666376?dopt=Citation>

APA

Frericks, B. B., Caldarone, F. C., Nashan, B., Savellano, D. H., Stamm, G., Kirchhoff, T. D., Shin, H-O., Schenk, A., Selle, D., Spindler, W., Klempnauer, J., Peitgen, H-O., & Galanski, M. (2004). 3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation. EUR RADIOL, 14(2), 326-333. [2]. http://www.ncbi.nlm.nih.gov/pubmed/14666376?dopt=Citation

Vancouver

Frericks BB, Caldarone FC, Nashan B, Savellano DH, Stamm G, Kirchhoff TD et al. 3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation. EUR RADIOL. 2004;14(2):326-333. 2.

Bibtex

@article{ad0fd44c21634083864b1bddba196872,
title = "3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation.",
abstract = "The aim of this study was to evaluate a software tool for non-invasive preoperative volumetric assessment of potential donors in living donated liver transplantation (LDLT). Biphasic helical CT was performed in 56 potential donors. Data sets were post-processed using a non-commercial software tool for segmentation, volumetric analysis and visualisation of liver segments. Semi-automatic definition of liver margins allowed the segmentation of parenchyma. Hepatic vessels were delineated using a region-growing algorithm with automatically determined thresholds. Volumes and shapes of liver segments were calculated automatically based on individual portal-venous branches. Results were visualised three-dimensionally and statistically compared with conventional volumetry and the intraoperative findings in 27 transplanted cases. Image processing was easy to perform within 23 min. Of the 56 potential donors, 27 were excluded from LDLT because of inappropriate liver parenchyma or vascular architecture. Two recipients were not transplanted due to poor clinical conditions. In the 27 transplanted cases, preoperatively visualised vessels were confirmed, and only one undetected accessory hepatic vein was revealed. Calculated graft volumes were 1110 +/- 180 ml for right lobes, 820 ml for the left lobe and 270 +/- 30 ml for segments II+III. The calculated volumes and intraoperatively measured graft volumes correlated significantly. No significant differences between the presented automatic volumetry and the conventional volumetry were observed. A novel image processing technique was evaluated which allows a semi-automatic volume calculation and 3D visualisation of the different liver segments.",
author = "Frericks, {Bernd B} and Caldarone, {Franco C} and Bj{\"o}rn Nashan and Savellano, {Dagmar H{\"o}gemann} and Georg Stamm and Kirchhoff, {Timm D} and Hoen-Oh Shin and Andrea Schenk and Dirk Selle and Wolf Spindler and J{\"u}rgen Klempnauer and Heinz-Otto Peitgen and Michael Galanski",
year = "2004",
language = "Deutsch",
volume = "14",
pages = "326--333",
journal = "EUR RADIOL",
issn = "0938-7994",
publisher = "Springer",
number = "2",

}

RIS

TY - JOUR

T1 - 3D CT modeling of hepatic vessel architecture and volume calculation in living donated liver transplantation.

AU - Frericks, Bernd B

AU - Caldarone, Franco C

AU - Nashan, Björn

AU - Savellano, Dagmar Högemann

AU - Stamm, Georg

AU - Kirchhoff, Timm D

AU - Shin, Hoen-Oh

AU - Schenk, Andrea

AU - Selle, Dirk

AU - Spindler, Wolf

AU - Klempnauer, Jürgen

AU - Peitgen, Heinz-Otto

AU - Galanski, Michael

PY - 2004

Y1 - 2004

N2 - The aim of this study was to evaluate a software tool for non-invasive preoperative volumetric assessment of potential donors in living donated liver transplantation (LDLT). Biphasic helical CT was performed in 56 potential donors. Data sets were post-processed using a non-commercial software tool for segmentation, volumetric analysis and visualisation of liver segments. Semi-automatic definition of liver margins allowed the segmentation of parenchyma. Hepatic vessels were delineated using a region-growing algorithm with automatically determined thresholds. Volumes and shapes of liver segments were calculated automatically based on individual portal-venous branches. Results were visualised three-dimensionally and statistically compared with conventional volumetry and the intraoperative findings in 27 transplanted cases. Image processing was easy to perform within 23 min. Of the 56 potential donors, 27 were excluded from LDLT because of inappropriate liver parenchyma or vascular architecture. Two recipients were not transplanted due to poor clinical conditions. In the 27 transplanted cases, preoperatively visualised vessels were confirmed, and only one undetected accessory hepatic vein was revealed. Calculated graft volumes were 1110 +/- 180 ml for right lobes, 820 ml for the left lobe and 270 +/- 30 ml for segments II+III. The calculated volumes and intraoperatively measured graft volumes correlated significantly. No significant differences between the presented automatic volumetry and the conventional volumetry were observed. A novel image processing technique was evaluated which allows a semi-automatic volume calculation and 3D visualisation of the different liver segments.

AB - The aim of this study was to evaluate a software tool for non-invasive preoperative volumetric assessment of potential donors in living donated liver transplantation (LDLT). Biphasic helical CT was performed in 56 potential donors. Data sets were post-processed using a non-commercial software tool for segmentation, volumetric analysis and visualisation of liver segments. Semi-automatic definition of liver margins allowed the segmentation of parenchyma. Hepatic vessels were delineated using a region-growing algorithm with automatically determined thresholds. Volumes and shapes of liver segments were calculated automatically based on individual portal-venous branches. Results were visualised three-dimensionally and statistically compared with conventional volumetry and the intraoperative findings in 27 transplanted cases. Image processing was easy to perform within 23 min. Of the 56 potential donors, 27 were excluded from LDLT because of inappropriate liver parenchyma or vascular architecture. Two recipients were not transplanted due to poor clinical conditions. In the 27 transplanted cases, preoperatively visualised vessels were confirmed, and only one undetected accessory hepatic vein was revealed. Calculated graft volumes were 1110 +/- 180 ml for right lobes, 820 ml for the left lobe and 270 +/- 30 ml for segments II+III. The calculated volumes and intraoperatively measured graft volumes correlated significantly. No significant differences between the presented automatic volumetry and the conventional volumetry were observed. A novel image processing technique was evaluated which allows a semi-automatic volume calculation and 3D visualisation of the different liver segments.