ID: 74102
Bernd Christopher Saugel
Publications
- 2021
Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis
Hoppe, P., Gleibs, F., Briesenick, L., Joosten, A. & Saugel, B., 10.2021, In: J CLIN MONIT COMPUT. 35, 5, p. 1203–1209 7 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Association between intraoperative mean arterial pressure and postoperative complications is independent of cardiac index in patients undergoing noncardiac surgery
Maheshwari, K., Pu, X., Rivas, E., Saugel, B., Turan, A., Schmidt, M. T., Ruetzler, K., Reiterer, C., Kabon, B., Kurz, A. & Sessler, D. I., 09.2021, In: BRIT J ANAESTH. 127, 3, p. e102-e104Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Relationship Between Intraoperative and Preoperative Ambulatory Nighttime Heart Rates: A Secondary Analysis of a Prospective Observational Study
Kouz, K., Hoppe, P., Reese, P., Burfeindt, C., Flick, M., Briesenick, L., Nitzschke, R., Pinnschmidt, H. & Saugel, B., 01.08.2021, In: ANESTH ANALG. 133, 2, p. 406-412 7 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Cardiovascular dynamics during peroral endoscopic myotomy for esophageal achalasia: a prospective observational study using non-invasive finger cuff-derived pulse wave analysis
Saugel, B., Vokuhl, C., Pinnschmidt, H. O., Rösch, T., Petzoldt, M. & Löser, B., 08.2021, In: J CLIN MONIT COMPUT. 35, 4, p. 827-834 8 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Agreement between continuous noninvasive finger cuff-derived and invasive arterial blood pressure measurements: Effect of data sampling and data processing
Flick, M., Matin Mehr, J., Briesenick, L., Hoppe, P., Kouz, K., Vokuhl, C., Flotzinger, D., Lerche, K. & Saugel, B., 01.06.2021, In: EUR J ANAESTH. 38, 6, p. 616-624 9 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
The effect of moderate intraoperative blood loss and norepinephrine therapy on sublingual microcirculatory perfusion in patients having open radical prostatectomy: An observational study
Flick, M., Briesenick, L., Peine, S., Scheeren, T. W. L., Duranteau, J. & Saugel, B., 01.05.2021, In: EUR J ANAESTH. 38, 5, p. 459-467 9 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Kommentar zur aktualisierten S3-Leitlinie zur intravasalen Volumentherapie beim Erwachsenen
Schneck, E., Sander, M., Saugel, B., Reuter, D. A. & Habicher, M., 05.2021, In: ANAESTHESIST. 70, 5, p. 413-419 7 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Blood Pressure Management by Anesthesia Professionals: Evaluating Clinician Skill From Electronic Medical Records
Sessler, D. I., Khan, M. Z., Maheshwari, K., Liu, L., Adegboye, J., Saugel, B. & Mascha, E. J., 01.04.2021, In: ANESTH ANALG. 132, 4, p. 946-956 11 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Agreement between continuous and intermittent pulmonary artery thermodilution for cardiac output measurement in perioperative and intensive care medicine: a systematic review and meta-analysis
Kouz, K., Michard, F., Bergholz, A., Vokuhl, C., Briesenick, L., Hoppe, P., Flick, M., Schön, G. & Saugel, B., 29.03.2021, In: CRIT CARE. 25, 1, p. 125Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
A novel art of continuous noninvasive blood pressure measurement
Fortin, J., Rogge, D. E., Fellner, C., Flotzinger, D., Grond, J., Lerche, K. & Saugel, B., 02.03.2021, In: NAT COMMUN. 12, 1, 1387.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Intraoperative Blood Pressure Monitoring in Obese Patients: Arterial Catheter, Finger Cuff, and Oscillometry
Schumann, R., Meidert, A. S., Bonney, I., Koutentis, C., Wesselink, W., Kouz, K. & Saugel, B., 01.02.2021, In: ANESTHESIOLOGY. 134, 2, p. 179-188 10 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Perioperative Blood Pressure Management
Saugel, B. & Sessler, D. I., 01.02.2021, In: ANESTHESIOLOGY. 134, 2, p. 250-261 12 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Education
Automated Blood Pressure Control
Rinehart, J., Lee, S., Saugel, B. & Joosten, A., 02.2021, In: SEMIN RESP CRIT CARE. 42, 1, p. 47-58 12 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Metrology part 1: definition of quality criteria
Squara, P., Scheeren, T. W. L., Aya, H. D., Bakker, J., Cecconi, M., Einav, S., Malbrain, M. L. N. G., Monnet, X., Reuter, D. A., van der Horst, I. C. C. & Saugel, B., 02.2021, In: J CLIN MONIT COMPUT. 35, 1, p. 17-25 9 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Metrology part 2: Procedures for the validation of major measurement quality criteria and measuring instrument properties
Squara, P., Scheeren, T. W. L., Aya, H. D., Bakker, J., Cecconi, M., Einav, S., Malbrain, M. L. N. G., Monnet, X., Reuter, D. A., van der Horst, I. C. C. & Saugel, B., 02.2021, In: J CLIN MONIT COMPUT. 35, 1, p. 27-37 11 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Current use of inotropes in circulatory shock
Scheeren, T. W. L., Bakker, J., Kaufmann, T., Annane, D., Asfar, P., Boerma, E. C., Cecconi, M., Chew, M. S., Cholley, B., Cronhjort, M., De Backer, D., Dubin, A., Dünser, M. W., Duranteau, J., Gordon, A. C., Hajjar, L. A., Hamzaoui, O., Hernandez, G., Kanoore Edul, V., Koster, G., Landoni, G., Leone, M., Levy, B., Martin, C., Mebazaa, A., Monnet, X., Morelli, A., Payen, D., Pearse, R. M., Pinsky, M. R., Radermacher, P., Reuter, D. A., Sakr, Y., Sander, M., Saugel, B., Singer, M., Squara, P., Vieillard-Baron, A., Vignon, P., Vincent, J-L., van der Horst, I. C. C., Vistisen, S. T. & Teboul, J-L., 29.01.2021, In: ANN INTENSIVE CARE. 11, 1, p. 21Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Intraoperative hypotension during liver transplant surgery is associated with postoperative acute kidney injury: a historical cohort study
Joosten, A., Lucidi, V., Ickx, B., Van Obbergh, L., Germanova, D., Berna, A., Alexander, B., Desebbe, O., Carrier, F-M., Cherqui, D., Adam, R., Duranteau, J., Saugel, B., Vincent, J-L., Rinehart, J. & Van der Linden, P., 11.01.2021, In: BMC ANESTHESIOL. 21, 1, 12.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Pulse Wave Analysis to Estimate Cardiac Output
Kouz, K., Scheeren, T. W. L., de Backer, D. & Saugel, B., 01.01.2021, In: ANESTHESIOLOGY. 134, 1, p. 119-126 8 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Cardiac output estimation using pulse wave analysis-physiology, algorithms, and technologies: a narrative review
Saugel, B., Kouz, K., Scheeren, T. W. L., Greiwe, G., Hoppe, P., Romagnoli, S. & de Backer, D., 01.2021, In: BRIT J ANAESTH. 126, 1, p. 67-76 10 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
- 2020
Hydraulic Coupling
Saugel, B., Kouz, K. & Sessler, D. I., 01.11.2020, In: ANESTHESIOLOGY. 133, 5, p. 964-966 3 p.Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Monitoring of the Sublingual Microcirculation During Cardiac Surgery: Current Knowledge and Future Directions
Flick, M., Duranteau, J., Scheeren, T. W. L. & Saugel, B., 01.10.2020, In: J CARDIOTHOR VASC AN. 34, 10, p. 2754-2765Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Technological Assessment and Objective Evaluation of Minimally Invasive and Noninvasive Cardiac Output Monitoring Systems
Saugel, B., Thiele, R. H., Hapfelmeier, A. & Cannesson, M., 01.10.2020, In: ANESTHESIOLOGY. 133, 4, p. 921-928 8 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Cardiac output estimation by pulse wave analysis using the pressure recording analytical method and intermittent pulmonary artery thermodilution: A method comparison study in patients after off-pump coronary artery bypass surgery
Greiwe, G., Luehsen, K., Hapfelmeier, A., Rogge, D., Kubik, M., Schulte-Uentrop, L. & Saugel, B., 10.2020, In: EUR J ANAESTH. 37, 10, p. 920-925 6 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Intraoperative hypotension is just the tip of the iceberg: a call for multimodal, individualised, contextualised management of intraoperative cardiovascular dynamics
Molnar, Z., Benes, J. & Saugel, B., 10.2020, In: BRIT J ANAESTH. 125, 4, p. 419-423 5 p.Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Perioperatives Blutdruckmanagement: Was ist der optimale Druck?
Welte, M., Saugel, B. & Reuter, D. A., 09.2020, In: ANAESTHESIST. 69, 9, p. 611-622 12 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Rethinking the post-COVID-19 pandemic hospital: more ICU beds or smart monitoring on the wards?
Michard, F., Saugel, B. & Vallet, B., 09.2020, In: INTENS CARE MED. 46, 9, p. 1792-1793 2 p.Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Hydroxyethyl starch for perioperative goal-directed fluid therapy in 2020: a narrative review
Joosten, A., Coeckelenbergh, S., Alexander, B., Delaporte, A., Cannesson, M., Duranteau, J., Saugel, B., Vincent, J-L. & Van der Linden, P., 20.08.2020, In: BMC ANESTHESIOL. 20, 1, p. 209Research output: SCORING: Contribution to journal › SCORING: Review article › Research
A glimpse into the future of postoperative arterial blood pressure monitoring
Michard, F., Scheeren, T. W. L. & Saugel, B., 08.2020, In: BRIT J ANAESTH. 125, 2, p. 113-115 3 p.Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Personalised haemodynamic management targeting baseline cardiac index in high-risk patients undergoing major abdominal surgery: a randomised single-centre clinical trial
Nicklas, J. Y., Diener, O., Leistenschneider, M., Sellhorn, C., Schön, G., Winkler, M., Daum, G., Schwedhelm, E., Schröder, J., Fisch, M., Schmalfeldt, B., Izbicki, J. R., Bauer, M., Coldewey, S. M., Reuter, D. A. & Saugel, B., 08.2020, In: BRIT J ANAESTH. 125, 2, p. 122-132 11 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Continuous noninvasive pulse wave analysis using finger cuff technologies for arterial blood pressure and cardiac output monitoring in perioperative and intensive care medicine: a systematic review and meta-analysis
Saugel, B., Hoppe, P., Nicklas, J. Y., Kouz, K., Körner, A., Hempel, J. C., Vos, J. J., Schön, G. & Scheeren, T. W. L., 07.2020, In: BRIT J ANAESTH. 125, 1, p. 25-37 13 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Correction to: How to measure blood pressure using an arterial catheter: a systematic 5-step approach
Saugel, B., Kouz, K., Meidert, A. S., Schulte-Uentrop, L. & Romagnoli, S., 23.06.2020, In: CRIT CARE. 24, 1, p. 374Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Continuous non-invasive haemodynamic monitoring in patients having surgery: Valuable tool or superfluous toy?
Joosten, A., Vincent, J-L. & Saugel, B., 06.2020, In: ANAESTH CRIT CARE PA. 39, 3, p. 417-418 2 p.Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Non-invasive oscillometric versus invasive arterial blood pressure measurements in critically ill patients: A post hoc analysis of a prospective observational study
Kaufmann, T., Cox, E. G. M., Wiersema, R., Hiemstra, B., Eck, R. J., Koster, G., Scheeren, T. W. L., Keus, F., Saugel, B., van der Horst, I. C. C. & SICS Study Group, 06.2020, In: J CRIT CARE. 57, p. 118-123 6 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Anesthesia for Patients Undergoing Peroral Endoscopic Myotomy Procedures: A Review of the Literature
Löser, B., Recio Ariza, O., Saugel, B., Reuter, D. A., Zöllner, C., Werner, Y. B., Rösch, T. & Petzoldt, M., 05.2020, In: ANESTH ANALG. 130, 5, p. 1331-1340 10 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
How to measure blood pressure using an arterial catheter: a systematic 5-step approach
Saugel, B., Kouz, K., Meidert, A. S., Schulte-Uentrop, L. & Romagnoli, S., 24.04.2020, In: CRIT CARE. 24, 1, p. 172Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Ambulatory and Perioperative Blood Pressure: Reply
Saugel, B. & Sessler, D. I., 04.2020, In: ANESTHESIOLOGY. 132, 4, p. 932-933 2 p.Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Journal of Clinical Monitoring and Computing end of year summary 2019: hemodynamic monitoring and management
Saugel, B., Critchley, L. A. H., Kaufmann, T., Flick, M., Kouz, K., Vistisen, S. T. & Scheeren, T. W. L., 04.2020, In: J CLIN MONIT COMPUT. 34, 2, p. 207-219 13 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Pulse pressure variation using a novel smartphone application (Capstesia) versus invasive pulse contour analysis in patients undergoing cardiac surgery: a secondary analysis focusing on clinical decision making
Desebbe, O., Vincent, J-L., Saugel, B., Rinehart, J. & Joosten, A., 04.2020, In: J CLIN MONIT COMPUT. 34, 2, p. 379-380 2 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Septic shock patients with adequate tissue perfusion parameters still need the recommended minimal Mean Arterial Pressure: For sure
De Backer, D., Teboul, J-L. & Saugel, B., 04.2020, In: J CRIT CARE. 56, p. 305-307 3 p.Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Automated Continuous Noninvasive Ward Monitoring: Validation of Measurement Systems Is the Real Challenge
Saugel, B., Hoppe, P. & Khanna, A. K., 03.2020, In: ANESTHESIOLOGY. 132, 3, p. 407-410 4 p.Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Computer Program for Error Grid Analysis in Arterial Blood Pressure Method Comparison Studies
Grothe, O., Kaplan, A., Kouz, K. & Saugel, B., 03.2020, In: ANESTH ANALG. 130, 3, p. e71-e74 4 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Intraoperative hypotension: Pathophysiology, clinical relevance, and therapeutic approaches
Kouz, K., Hoppe, P., Briesenick, L. & Saugel, B., 02.2020, In: INDIAN J ANAESTH. 64, 2, p. 90-96 7 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Mobile Devices for Hemodynamic Monitoring
Briesenick, L., Saugel, B. C. & Michard, F., 2020, Annual Update in Intensive Care and Emergency Medicine. Springer International Publishing, p. 655-665 10 p.Research output: SCORING: Contribution to book/anthology › Conference contribution - Article for conference › Research › peer-review
- 2019
Monitoring of pulse pressure variation using a new smartphone application (Capstesia) versus stroke volume variation using an uncalibrated pulse wave analysis monitor: a clinical decision making study during major abdominal surgery
Joosten, A., Jacobs, A., Desebbe, O., Vincent, J-L., Sarah, S., Rinehart, J., Van Obbergh, L., Hapfelmeier, A. & Saugel, B., 10.2019, In: J CLIN MONIT COMPUT. 33, 5, p. 787-793 7 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Grundlagen und Fallstricke der arteriellen Blutdruckmessung
Meidert, A. S., Briegel, J. & Saugel, B., 09.2019, In: ANAESTHESIST. 68, 9, p. 637-650 14 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research
Is this patient really "(un)stable"? How to describe cardiovascular dynamics in critically ill patients
Vincent, J-L., Cecconi, M. & Saugel, B., 06.08.2019, In: CRIT CARE. 23, 1, p. 272Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
Protocolised personalised peri-operative haemodynamic management
Saugel, B. & Vincent, J-L., 08.2019, In: EUR J ANAESTH. 36, 8, p. 551-554 4 p.Research output: SCORING: Contribution to journal › Other (editorial matter etc.) › Research
The '5 Ts' of perioperative goal-directed haemodynamic therapy
Saugel, B., Kouz, K. & Scheeren, T. W. L., 08.2019, In: BRIT J ANAESTH. 123, 2, p. 103-107 5 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Automated Ambulatory Blood Pressure Measurements and Intraoperative Hypotension in Patients Having Noncardiac Surgery with General Anesthesia: A Prospective Observational Study
Saugel, B., Reese, P. C., Sessler, D. I., Burfeindt, C., Nicklas, J. Y., Pinnschmidt, H. O., Reuter, D. A. & Südfeld, S., 07.2019, In: ANESTHESIOLOGY. 131, 1, p. 74-83 10 p.Research output: SCORING: Contribution to journal › SCORING: Journal article › Research › peer-review
Noninvasive Cardiac Output Monitoring in Cardiothoracic Surgery Patients: Available Methods and Future Directions
Saugel, B., Cecconi, M. & Hajjar, L. A., 06.2019, In: J CARDIOTHOR VASC AN. 33, 6, p. 1742-1752 11 p.Research output: SCORING: Contribution to journal › SCORING: Review article › Research