Value of two cone-beam computed tomography systems from an orthodontic point of view.

Standard

Value of two cone-beam computed tomography systems from an orthodontic point of view. / Korbmacher, Heike; Kahl-Nieke, Bärbel; Schöllchen, Max; Heiland, Max.

in: J OROFAC ORTHOP, Jahrgang 68, Nr. 4, 4, 2007, S. 278-289.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{3504866c7802450da4fb8baf8896b458,
title = "Value of two cone-beam computed tomography systems from an orthodontic point of view.",
abstract = "AIM: Since its introduction in dental radiology in 1998, cone-beam computed tomography (CBCT) has found increasing acceptance in clinical routine. The aim of this study was thus to evaluate this imaging modality from an orthodontic point of view. MATERIALS AND METHODS: Two systems formed the basis of this investigation: the NewTom 9000 (NewTom Germany AG, Marburg, Germany), in use at the University Medical Center Hamburg-Eppendorf since October 2002, and the mobile Arcadis Orbic 3D system (Siemens Medical Solutions, Erlangen, Germany), which was introduced in February 2005. Two independent examiners evaluated a total of 68 NewTom and 15 Arcadis Orbic 3D images involving orthodontic indications. The images were categorized according to their indications and diagnostic value assessed according to a predefined and quantifiable protocol. Information obtained from the CBCT was also compared to that gleaned from conventional radiographs. RESULTS: The indication for the NewTom images in cleft patients as well as for all Arcadis Orbic 3D images was considered justified. The osseous morphology of the cleft and position of osteosynthetic screws and plates were particularly well visualized. CBCT implementation in cases of tooth impaction or for assessing third molars was considered justified, although its value was judged differently by the two examiners. CBCT did not provide more information than conventional imaging regarding cartilaginous joint structures. CONCLUSIONS: In complex orthodontic cases in which 3D imaging is mandatory, CBCT is the method of choice. Furthermore, in cleft patients and those undergoing combined orthodontic and maxillofacial therapy, CBCT proved advantageous, providing more information than conventional images.",
author = "Heike Korbmacher and B{\"a}rbel Kahl-Nieke and Max Sch{\"o}llchen and Max Heiland",
year = "2007",
language = "Deutsch",
volume = "68",
pages = "278--289",
journal = "J OROFAC ORTHOP",
issn = "1434-5293",
publisher = "Urban und Vogel",
number = "4",

}

RIS

TY - JOUR

T1 - Value of two cone-beam computed tomography systems from an orthodontic point of view.

AU - Korbmacher, Heike

AU - Kahl-Nieke, Bärbel

AU - Schöllchen, Max

AU - Heiland, Max

PY - 2007

Y1 - 2007

N2 - AIM: Since its introduction in dental radiology in 1998, cone-beam computed tomography (CBCT) has found increasing acceptance in clinical routine. The aim of this study was thus to evaluate this imaging modality from an orthodontic point of view. MATERIALS AND METHODS: Two systems formed the basis of this investigation: the NewTom 9000 (NewTom Germany AG, Marburg, Germany), in use at the University Medical Center Hamburg-Eppendorf since October 2002, and the mobile Arcadis Orbic 3D system (Siemens Medical Solutions, Erlangen, Germany), which was introduced in February 2005. Two independent examiners evaluated a total of 68 NewTom and 15 Arcadis Orbic 3D images involving orthodontic indications. The images were categorized according to their indications and diagnostic value assessed according to a predefined and quantifiable protocol. Information obtained from the CBCT was also compared to that gleaned from conventional radiographs. RESULTS: The indication for the NewTom images in cleft patients as well as for all Arcadis Orbic 3D images was considered justified. The osseous morphology of the cleft and position of osteosynthetic screws and plates were particularly well visualized. CBCT implementation in cases of tooth impaction or for assessing third molars was considered justified, although its value was judged differently by the two examiners. CBCT did not provide more information than conventional imaging regarding cartilaginous joint structures. CONCLUSIONS: In complex orthodontic cases in which 3D imaging is mandatory, CBCT is the method of choice. Furthermore, in cleft patients and those undergoing combined orthodontic and maxillofacial therapy, CBCT proved advantageous, providing more information than conventional images.

AB - AIM: Since its introduction in dental radiology in 1998, cone-beam computed tomography (CBCT) has found increasing acceptance in clinical routine. The aim of this study was thus to evaluate this imaging modality from an orthodontic point of view. MATERIALS AND METHODS: Two systems formed the basis of this investigation: the NewTom 9000 (NewTom Germany AG, Marburg, Germany), in use at the University Medical Center Hamburg-Eppendorf since October 2002, and the mobile Arcadis Orbic 3D system (Siemens Medical Solutions, Erlangen, Germany), which was introduced in February 2005. Two independent examiners evaluated a total of 68 NewTom and 15 Arcadis Orbic 3D images involving orthodontic indications. The images were categorized according to their indications and diagnostic value assessed according to a predefined and quantifiable protocol. Information obtained from the CBCT was also compared to that gleaned from conventional radiographs. RESULTS: The indication for the NewTom images in cleft patients as well as for all Arcadis Orbic 3D images was considered justified. The osseous morphology of the cleft and position of osteosynthetic screws and plates were particularly well visualized. CBCT implementation in cases of tooth impaction or for assessing third molars was considered justified, although its value was judged differently by the two examiners. CBCT did not provide more information than conventional imaging regarding cartilaginous joint structures. CONCLUSIONS: In complex orthodontic cases in which 3D imaging is mandatory, CBCT is the method of choice. Furthermore, in cleft patients and those undergoing combined orthodontic and maxillofacial therapy, CBCT proved advantageous, providing more information than conventional images.

M3 - SCORING: Zeitschriftenaufsatz

VL - 68

SP - 278

EP - 289

JO - J OROFAC ORTHOP

JF - J OROFAC ORTHOP

SN - 1434-5293

IS - 4

M1 - 4

ER -