Using eddy currents for noninvasive in vivo pH monitoring for bone tissue engineering

Standard

Using eddy currents for noninvasive in vivo pH monitoring for bone tissue engineering. / Beck-Broichsitter, Benedicta E; Daschner, Frank; Christofzik, David W; Knöchel, Reinhard; Wiltfang, Jörg; Becker, Stephan T.

in: ORAL MAXILLOFAC SURG, Jahrgang 19, Nr. 1, 01.03.2015, S. 55-60.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

Beck-Broichsitter, BE, Daschner, F, Christofzik, DW, Knöchel, R, Wiltfang, J & Becker, ST 2015, 'Using eddy currents for noninvasive in vivo pH monitoring for bone tissue engineering', ORAL MAXILLOFAC SURG, Jg. 19, Nr. 1, S. 55-60. https://doi.org/10.1007/s10006-014-0453-6

APA

Beck-Broichsitter, B. E., Daschner, F., Christofzik, D. W., Knöchel, R., Wiltfang, J., & Becker, S. T. (2015). Using eddy currents for noninvasive in vivo pH monitoring for bone tissue engineering. ORAL MAXILLOFAC SURG, 19(1), 55-60. https://doi.org/10.1007/s10006-014-0453-6

Vancouver

Beck-Broichsitter BE, Daschner F, Christofzik DW, Knöchel R, Wiltfang J, Becker ST. Using eddy currents for noninvasive in vivo pH monitoring for bone tissue engineering. ORAL MAXILLOFAC SURG. 2015 Mär 1;19(1):55-60. https://doi.org/10.1007/s10006-014-0453-6

Bibtex

@article{2571e164fb04487f907ac4d029ecc48d,
title = "Using eddy currents for noninvasive in vivo pH monitoring for bone tissue engineering",
abstract = "PURPOSE: The metabolic processes that regulate bone healing and bone induction in tissue engineering models are not fully understood. Eddy current excitation is widely used in technical approaches and in the food industry. The aim of this study was to establish eddy current excitation for monitoring metabolic processes during heterotopic osteoinduction in vivo.METHODS: Hydroxyapatite scaffolds were implanted into the musculus latissimus dorsi of six rats. Bone morphogenetic protein 2 (BMP-2) was applied 1 and 2 weeks after implantation. Weekly eddy current excitation measurements were performed. Additionally, invasive pH measurements were obtained from the scaffolds using fiber optic detection devices. Correlations between the eddy current measurements and the metabolic values were calculated.RESULTS: The eddy current measurements and pH values decreased significantly in the first 2 weeks of the study, followed by a steady increase and stabilization at higher levels towards the end of the study. The measurement curves and statistical evaluations indicated a significant correlation between the resonance frequency values of the eddy current excitation measurements and the observed pH levels (p = 0.0041).CONCLUSIONS: This innovative technique was capable of noninvasively monitoring metabolic processes in living tissues according to pH values, showing a direct correlation between eddy current excitation and pH in an in vivo tissue engineering model.",
author = "Beck-Broichsitter, {Benedicta E} and Frank Daschner and Christofzik, {David W} and Reinhard Kn{\"o}chel and J{\"o}rg Wiltfang and Becker, {Stephan T}",
year = "2015",
month = mar,
day = "1",
doi = "10.1007/s10006-014-0453-6",
language = "English",
volume = "19",
pages = "55--60",
journal = "ORAL MAXILLOFAC SURG",
issn = "1865-1550",
publisher = "Springer",
number = "1",

}

RIS

TY - JOUR

T1 - Using eddy currents for noninvasive in vivo pH monitoring for bone tissue engineering

AU - Beck-Broichsitter, Benedicta E

AU - Daschner, Frank

AU - Christofzik, David W

AU - Knöchel, Reinhard

AU - Wiltfang, Jörg

AU - Becker, Stephan T

PY - 2015/3/1

Y1 - 2015/3/1

N2 - PURPOSE: The metabolic processes that regulate bone healing and bone induction in tissue engineering models are not fully understood. Eddy current excitation is widely used in technical approaches and in the food industry. The aim of this study was to establish eddy current excitation for monitoring metabolic processes during heterotopic osteoinduction in vivo.METHODS: Hydroxyapatite scaffolds were implanted into the musculus latissimus dorsi of six rats. Bone morphogenetic protein 2 (BMP-2) was applied 1 and 2 weeks after implantation. Weekly eddy current excitation measurements were performed. Additionally, invasive pH measurements were obtained from the scaffolds using fiber optic detection devices. Correlations between the eddy current measurements and the metabolic values were calculated.RESULTS: The eddy current measurements and pH values decreased significantly in the first 2 weeks of the study, followed by a steady increase and stabilization at higher levels towards the end of the study. The measurement curves and statistical evaluations indicated a significant correlation between the resonance frequency values of the eddy current excitation measurements and the observed pH levels (p = 0.0041).CONCLUSIONS: This innovative technique was capable of noninvasively monitoring metabolic processes in living tissues according to pH values, showing a direct correlation between eddy current excitation and pH in an in vivo tissue engineering model.

AB - PURPOSE: The metabolic processes that regulate bone healing and bone induction in tissue engineering models are not fully understood. Eddy current excitation is widely used in technical approaches and in the food industry. The aim of this study was to establish eddy current excitation for monitoring metabolic processes during heterotopic osteoinduction in vivo.METHODS: Hydroxyapatite scaffolds were implanted into the musculus latissimus dorsi of six rats. Bone morphogenetic protein 2 (BMP-2) was applied 1 and 2 weeks after implantation. Weekly eddy current excitation measurements were performed. Additionally, invasive pH measurements were obtained from the scaffolds using fiber optic detection devices. Correlations between the eddy current measurements and the metabolic values were calculated.RESULTS: The eddy current measurements and pH values decreased significantly in the first 2 weeks of the study, followed by a steady increase and stabilization at higher levels towards the end of the study. The measurement curves and statistical evaluations indicated a significant correlation between the resonance frequency values of the eddy current excitation measurements and the observed pH levels (p = 0.0041).CONCLUSIONS: This innovative technique was capable of noninvasively monitoring metabolic processes in living tissues according to pH values, showing a direct correlation between eddy current excitation and pH in an in vivo tissue engineering model.

U2 - 10.1007/s10006-014-0453-6

DO - 10.1007/s10006-014-0453-6

M3 - SCORING: Journal article

C2 - 24998887

VL - 19

SP - 55

EP - 60

JO - ORAL MAXILLOFAC SURG

JF - ORAL MAXILLOFAC SURG

SN - 1865-1550

IS - 1

ER -