Transvaginal and transabdominal extended field-of-view (EFOV) and power doppler EFOV sonography in gynecology: advantages and applications

Standard

Transvaginal and transabdominal extended field-of-view (EFOV) and power doppler EFOV sonography in gynecology: advantages and applications. / Henrich, Wolfgang; Fuchs, Ilka; Schmider, Annette; Bühling, Kai J; Dudenhausen, Joachim W.

in: J ULTRAS MED, Jahrgang 21, Nr. 10, 01.10.2002, S. 1137-44.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

Henrich, W, Fuchs, I, Schmider, A, Bühling, KJ & Dudenhausen, JW 2002, 'Transvaginal and transabdominal extended field-of-view (EFOV) and power doppler EFOV sonography in gynecology: advantages and applications', J ULTRAS MED, Jg. 21, Nr. 10, S. 1137-44.

APA

Henrich, W., Fuchs, I., Schmider, A., Bühling, K. J., & Dudenhausen, J. W. (2002). Transvaginal and transabdominal extended field-of-view (EFOV) and power doppler EFOV sonography in gynecology: advantages and applications. J ULTRAS MED, 21(10), 1137-44.

Vancouver

Bibtex

@article{3c3206ff36274c489b7c772b2e66e6a6,
title = "Transvaginal and transabdominal extended field-of-view (EFOV) and power doppler EFOV sonography in gynecology: advantages and applications",
abstract = "OBJECTIVE: To evaluate the possible advantages, applications, and usefulness of real-time transabdominal and transvaginal extended field-of-view sonography combined with power Doppler sonography in gynecology.METHODS: A series of 63 gynecologic patients, referred for preoperative sonographic examination and for whom the examiner thought that extended field-of-view sonography might be helpful in imaging pathologic findings, were selected. Patients were examined with conventional vaginal and abdominal B-mode sonography, extended field-of-view sonography, and power Doppler extended field-of-view sonography. A sonographic system with 3.5- to 7-MHz transducers was used to study and document pathologic findings.RESULTS: Extended field-of-view sonography provided a superior overview of pathologic findings and topography by creating a single image showing the relationship to reference structures. The combination of power Doppler extended field-of-view sonography provided additional information on the perfusion pattern in huge masses. In comparison with conventional sonographic images, the extended field-of-view sonographic images were easier to interpret by the referring or nonexamining physician. A list of proposed gynecologic applications for the use of extended field-of-view sonography was compiled.CONCLUSIONS: The extended field-of-view and power Doppler extended field-of-view sonographic technique provides documentation of surroundings, topographic orientation, and perfusion patterns in large pelvic masses and findings that exceed the limitations of the conventional sonographic sector. The clinical applications and advantages of extended field-of-view and power Doppler extended field-of-view imaging in gynecologic sonography are illustrated.",
keywords = "Abdomen, Adolescent, Adult, Aged, Aged, 80 and over, Female, Genital Diseases, Female, Genitalia, Female, Humans, Middle Aged, Pelvis, Ultrasonography, Doppler",
author = "Wolfgang Henrich and Ilka Fuchs and Annette Schmider and B{\"u}hling, {Kai J} and Dudenhausen, {Joachim W}",
year = "2002",
month = oct,
day = "1",
language = "English",
volume = "21",
pages = "1137--44",
journal = "J ULTRAS MED",
issn = "0278-4297",
publisher = "American Institute of Ultrasound in Medicine",
number = "10",

}

RIS

TY - JOUR

T1 - Transvaginal and transabdominal extended field-of-view (EFOV) and power doppler EFOV sonography in gynecology: advantages and applications

AU - Henrich, Wolfgang

AU - Fuchs, Ilka

AU - Schmider, Annette

AU - Bühling, Kai J

AU - Dudenhausen, Joachim W

PY - 2002/10/1

Y1 - 2002/10/1

N2 - OBJECTIVE: To evaluate the possible advantages, applications, and usefulness of real-time transabdominal and transvaginal extended field-of-view sonography combined with power Doppler sonography in gynecology.METHODS: A series of 63 gynecologic patients, referred for preoperative sonographic examination and for whom the examiner thought that extended field-of-view sonography might be helpful in imaging pathologic findings, were selected. Patients were examined with conventional vaginal and abdominal B-mode sonography, extended field-of-view sonography, and power Doppler extended field-of-view sonography. A sonographic system with 3.5- to 7-MHz transducers was used to study and document pathologic findings.RESULTS: Extended field-of-view sonography provided a superior overview of pathologic findings and topography by creating a single image showing the relationship to reference structures. The combination of power Doppler extended field-of-view sonography provided additional information on the perfusion pattern in huge masses. In comparison with conventional sonographic images, the extended field-of-view sonographic images were easier to interpret by the referring or nonexamining physician. A list of proposed gynecologic applications for the use of extended field-of-view sonography was compiled.CONCLUSIONS: The extended field-of-view and power Doppler extended field-of-view sonographic technique provides documentation of surroundings, topographic orientation, and perfusion patterns in large pelvic masses and findings that exceed the limitations of the conventional sonographic sector. The clinical applications and advantages of extended field-of-view and power Doppler extended field-of-view imaging in gynecologic sonography are illustrated.

AB - OBJECTIVE: To evaluate the possible advantages, applications, and usefulness of real-time transabdominal and transvaginal extended field-of-view sonography combined with power Doppler sonography in gynecology.METHODS: A series of 63 gynecologic patients, referred for preoperative sonographic examination and for whom the examiner thought that extended field-of-view sonography might be helpful in imaging pathologic findings, were selected. Patients were examined with conventional vaginal and abdominal B-mode sonography, extended field-of-view sonography, and power Doppler extended field-of-view sonography. A sonographic system with 3.5- to 7-MHz transducers was used to study and document pathologic findings.RESULTS: Extended field-of-view sonography provided a superior overview of pathologic findings and topography by creating a single image showing the relationship to reference structures. The combination of power Doppler extended field-of-view sonography provided additional information on the perfusion pattern in huge masses. In comparison with conventional sonographic images, the extended field-of-view sonographic images were easier to interpret by the referring or nonexamining physician. A list of proposed gynecologic applications for the use of extended field-of-view sonography was compiled.CONCLUSIONS: The extended field-of-view and power Doppler extended field-of-view sonographic technique provides documentation of surroundings, topographic orientation, and perfusion patterns in large pelvic masses and findings that exceed the limitations of the conventional sonographic sector. The clinical applications and advantages of extended field-of-view and power Doppler extended field-of-view imaging in gynecologic sonography are illustrated.

KW - Abdomen

KW - Adolescent

KW - Adult

KW - Aged

KW - Aged, 80 and over

KW - Female

KW - Genital Diseases, Female

KW - Genitalia, Female

KW - Humans

KW - Middle Aged

KW - Pelvis

KW - Ultrasonography, Doppler

M3 - SCORING: Journal article

C2 - 12369669

VL - 21

SP - 1137

EP - 1144

JO - J ULTRAS MED

JF - J ULTRAS MED

SN - 0278-4297

IS - 10

ER -