Transcutaneous lead implantation connected to an externalized pacemaker in patients with implantable cardiac defibrillator/pacemaker infection and pacemaker dependency
Standard
Transcutaneous lead implantation connected to an externalized pacemaker in patients with implantable cardiac defibrillator/pacemaker infection and pacemaker dependency. / Pecha, Simon; Aydin, Muhammed Ali; Yildirim, Yalin; Sill, Björn; Reiter, Beate; Wilke, Iris; Reichenspurner, Hermann; Treede, Hendrik.
in: EUROPACE, Jahrgang 15, Nr. 8, 08.2013, S. 1205-1209.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Transcutaneous lead implantation connected to an externalized pacemaker in patients with implantable cardiac defibrillator/pacemaker infection and pacemaker dependency
AU - Pecha, Simon
AU - Aydin, Muhammed Ali
AU - Yildirim, Yalin
AU - Sill, Björn
AU - Reiter, Beate
AU - Wilke, Iris
AU - Reichenspurner, Hermann
AU - Treede, Hendrik
PY - 2013/8
Y1 - 2013/8
N2 - AIMS: Systemic cardiac implantable electronic device (CIED) infection is a serious complication, especially in patients with pacemaker (PM) dependency. In those patients after infectious device removal temporary pacing is necessary, to obtain adequate haemodynamics. In this study, a new therapy option with temporary pacing by ipsilateral implantation of a new active-fixation right ventricular (RV)-lead was evaluated.METHODS AND RESULTS: Between September 2009 and November 2011, infectious lead removal was performed in 17 patients with systemic CIED infection. Temporary pacing was achieved by simultaneous implantation of a new active-fixation RV-lead, which then was connected extracorporally to the old CIED device. Antibiotic therapy was initiated. When laboratory infection parameters were in normal range and blood culture samples showed negative results, new CIED was implanted on contralateral side and temporary RV-lead was removed. Mean patients' age was 71.3 ± 9.1 years. Mean C-reactive protein values were 79.3 mg/dL, and mean leucocytes counts were 12.6 × 10(3). After lead extraction, temporary pacing was necessary in all patients due to severe bradycardia. Mean duration of temporary pacing was 12.7 (6-24) days. No major procedure-related peri- or post-operative adverse events occurred. Mean time of hospitalization was 20.8 (10-48) days. Mean follow-up time was 21.1 months (12-36), showing survival rate of 100% and freedom from reinfection in all patients.CONCLUSION: Ipsilateral implantation of a temporary active-fixation RV-lead connected to an externalized PM and pursued antibiotic therapy seems to be a good option for patients with CIED infection and PM dependency, showing no temporary pacing-related complications and no reinfection after mean follow-up time of 21.1 months.
AB - AIMS: Systemic cardiac implantable electronic device (CIED) infection is a serious complication, especially in patients with pacemaker (PM) dependency. In those patients after infectious device removal temporary pacing is necessary, to obtain adequate haemodynamics. In this study, a new therapy option with temporary pacing by ipsilateral implantation of a new active-fixation right ventricular (RV)-lead was evaluated.METHODS AND RESULTS: Between September 2009 and November 2011, infectious lead removal was performed in 17 patients with systemic CIED infection. Temporary pacing was achieved by simultaneous implantation of a new active-fixation RV-lead, which then was connected extracorporally to the old CIED device. Antibiotic therapy was initiated. When laboratory infection parameters were in normal range and blood culture samples showed negative results, new CIED was implanted on contralateral side and temporary RV-lead was removed. Mean patients' age was 71.3 ± 9.1 years. Mean C-reactive protein values were 79.3 mg/dL, and mean leucocytes counts were 12.6 × 10(3). After lead extraction, temporary pacing was necessary in all patients due to severe bradycardia. Mean duration of temporary pacing was 12.7 (6-24) days. No major procedure-related peri- or post-operative adverse events occurred. Mean time of hospitalization was 20.8 (10-48) days. Mean follow-up time was 21.1 months (12-36), showing survival rate of 100% and freedom from reinfection in all patients.CONCLUSION: Ipsilateral implantation of a temporary active-fixation RV-lead connected to an externalized PM and pursued antibiotic therapy seems to be a good option for patients with CIED infection and PM dependency, showing no temporary pacing-related complications and no reinfection after mean follow-up time of 21.1 months.
KW - Aged
KW - Anti-Bacterial Agents/administration & dosage
KW - Defibrillators, Implantable/adverse effects
KW - Device Removal/adverse effects
KW - Electrodes, Implanted/adverse effects
KW - Female
KW - Humans
KW - Male
KW - Pacemaker, Artificial/adverse effects
KW - Premedication/methods
KW - Prosthesis-Related Infections/etiology
KW - Treatment Outcome
U2 - 10.1093/europace/eut031
DO - 10.1093/europace/eut031
M3 - SCORING: Journal article
C2 - 23426553
VL - 15
SP - 1205
EP - 1209
JO - EUROPACE
JF - EUROPACE
SN - 1099-5129
IS - 8
ER -