The use of the "cross over technique" in the management of a traumatic vertebro-vertebral fistula.

Standard

The use of the "cross over technique" in the management of a traumatic vertebro-vertebral fistula. / Freitag, H J; Grzyska, U; Zeumer, Hermann.

in: NEURORADIOLOGY, Jahrgang 31, Nr. 2, 2, 1989, S. 174-176.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{8a899e3cbd8144c2b43537610d297ca5,
title = "The use of the {"}cross over technique{"} in the management of a traumatic vertebro-vertebral fistula.",
abstract = "A case of dissecting stab wound injury to the right vertebral artery with a vertebro-vertebral fistula is reported. Since a complete occlusion of a VV-fistula was not possible from a proximal approach with detachable balloons only retrograde catheterisation of the right vertebral artery via the left vertebral artery was undertaken (cross over technique). The introduction of thrombogenic platinum-coils led to a successful and complete occlusion of the fistula.",
author = "Freitag, {H J} and U Grzyska and Hermann Zeumer",
year = "1989",
language = "Deutsch",
volume = "31",
pages = "174--176",
journal = "NEURORADIOLOGY",
issn = "0028-3940",
publisher = "Springer",
number = "2",

}

RIS

TY - JOUR

T1 - The use of the "cross over technique" in the management of a traumatic vertebro-vertebral fistula.

AU - Freitag, H J

AU - Grzyska, U

AU - Zeumer, Hermann

PY - 1989

Y1 - 1989

N2 - A case of dissecting stab wound injury to the right vertebral artery with a vertebro-vertebral fistula is reported. Since a complete occlusion of a VV-fistula was not possible from a proximal approach with detachable balloons only retrograde catheterisation of the right vertebral artery via the left vertebral artery was undertaken (cross over technique). The introduction of thrombogenic platinum-coils led to a successful and complete occlusion of the fistula.

AB - A case of dissecting stab wound injury to the right vertebral artery with a vertebro-vertebral fistula is reported. Since a complete occlusion of a VV-fistula was not possible from a proximal approach with detachable balloons only retrograde catheterisation of the right vertebral artery via the left vertebral artery was undertaken (cross over technique). The introduction of thrombogenic platinum-coils led to a successful and complete occlusion of the fistula.

M3 - SCORING: Zeitschriftenaufsatz

VL - 31

SP - 174

EP - 176

JO - NEURORADIOLOGY

JF - NEURORADIOLOGY

SN - 0028-3940

IS - 2

M1 - 2

ER -