Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome.

Standard

Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome. / Rau, Thomas; Schofer, J; Schlüter, M; Seidensticker, A; Berger, J; Mathey, D G.

in: J AM COLL CARDIOL, Jahrgang 31, Nr. 2, 2, 1998, S. 275-280.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

Rau, T, Schofer, J, Schlüter, M, Seidensticker, A, Berger, J & Mathey, DG 1998, 'Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome.', J AM COLL CARDIOL, Jg. 31, Nr. 2, 2, S. 275-280. <http://www.ncbi.nlm.nih.gov/pubmed/9462567?dopt=Citation>

APA

Rau, T., Schofer, J., Schlüter, M., Seidensticker, A., Berger, J., & Mathey, D. G. (1998). Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome. J AM COLL CARDIOL, 31(2), 275-280. [2]. http://www.ncbi.nlm.nih.gov/pubmed/9462567?dopt=Citation

Vancouver

Rau T, Schofer J, Schlüter M, Seidensticker A, Berger J, Mathey DG. Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome. J AM COLL CARDIOL. 1998;31(2):275-280. 2.

Bibtex

@article{72a2b2298cf549a083a3d4874a0dd00d,
title = "Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome.",
abstract = "OBJECTIVES: This study was designed to determine and assess factors predictive of the intermediate-term outcome of stenting of nonacute total coronary occlusions. BACKGROUND: Balloon angioplasty of recanalized coronary occlusions is associated with a combined restenosis/reocclusion rate of up to 65%. Adjunctive stenting holds the potential to reduce this rate significantly. However, variables affecting the late angiographic outcome of coronary stenting in the setting of a total occlusion have not been elucidated sufficiently. METHODS: Coronary stenting was performed in 143 consecutive patients with a nonacute total occlusion; 120 of these patients (84%), with a total of 121 occlusions, underwent repeat angiography within 6 months and comprised the study group. High pressure stent implantation aimed to cover the site of the occlusion as well as adjacent diameter stenoses > or = 70% and all possibly induced dissections. Pertinent angiographic and procedural variables obtained at the time of the intervention were entered into a multivariate logistic regression analysis model to assess their influence on the angiographic outcome at follow-up. RESULTS: Mean preinterventional reference lumen diameter for the 121 vessels was 2.99 +/- 0.53 mm (mean +/- SD); occlusion length ranged from 4 to 44 mm (median of 7.7). After balloon angioplasty, dissections were found in 80% of patients. Lesions were covered with stents a median of 16 mm in length (range 8 to 53). The minimal lumen diameter (MLD) achieved after stenting was 2.89 +/- 0.48 mm. After a median follow-up period of 4.5 months, mean MLD was assessed at 1.91 +/- 0.90 mm, corresponding to a loss index of 0.34 +/- 0.31. There were 27 vessels with a nonocclusive restenosis > or = 50% and 8 with a reocclusion, for a combined restenosis/reocclusion rate of 29%. Factors found to adversely influence angiographic outcome were a post-stenting MLD 16 mm, a balloon/vessel diameter ratio for final stent expansion <or = 1.00 and the presence of a dissection after balloon angioplasty. CONCLUSIONS: Compared with previous reports on stand-alone balloon angioplasty, stenting of nonacute total coronary occlusions lowers the 6-month restenosis/reocclusion rate to approximately 30%. The late procedural outcome is independently and statistically significantly influenced by the MLD after stenting, the length of the stented vessel segment, the balloon/vessel diameter ratio for final stent expansion and the incidence of dissections after balloon angioplasty.",
author = "Thomas Rau and J Schofer and M Schl{\"u}ter and A Seidensticker and J Berger and Mathey, {D G}",
year = "1998",
language = "Deutsch",
volume = "31",
pages = "275--280",
journal = "J AM COLL CARDIOL",
issn = "0735-1097",
publisher = "Elsevier USA",
number = "2",

}

RIS

TY - JOUR

T1 - Stenting of nonacute total coronary occlusions: predictors of late angiographic outcome.

AU - Rau, Thomas

AU - Schofer, J

AU - Schlüter, M

AU - Seidensticker, A

AU - Berger, J

AU - Mathey, D G

PY - 1998

Y1 - 1998

N2 - OBJECTIVES: This study was designed to determine and assess factors predictive of the intermediate-term outcome of stenting of nonacute total coronary occlusions. BACKGROUND: Balloon angioplasty of recanalized coronary occlusions is associated with a combined restenosis/reocclusion rate of up to 65%. Adjunctive stenting holds the potential to reduce this rate significantly. However, variables affecting the late angiographic outcome of coronary stenting in the setting of a total occlusion have not been elucidated sufficiently. METHODS: Coronary stenting was performed in 143 consecutive patients with a nonacute total occlusion; 120 of these patients (84%), with a total of 121 occlusions, underwent repeat angiography within 6 months and comprised the study group. High pressure stent implantation aimed to cover the site of the occlusion as well as adjacent diameter stenoses > or = 70% and all possibly induced dissections. Pertinent angiographic and procedural variables obtained at the time of the intervention were entered into a multivariate logistic regression analysis model to assess their influence on the angiographic outcome at follow-up. RESULTS: Mean preinterventional reference lumen diameter for the 121 vessels was 2.99 +/- 0.53 mm (mean +/- SD); occlusion length ranged from 4 to 44 mm (median of 7.7). After balloon angioplasty, dissections were found in 80% of patients. Lesions were covered with stents a median of 16 mm in length (range 8 to 53). The minimal lumen diameter (MLD) achieved after stenting was 2.89 +/- 0.48 mm. After a median follow-up period of 4.5 months, mean MLD was assessed at 1.91 +/- 0.90 mm, corresponding to a loss index of 0.34 +/- 0.31. There were 27 vessels with a nonocclusive restenosis > or = 50% and 8 with a reocclusion, for a combined restenosis/reocclusion rate of 29%. Factors found to adversely influence angiographic outcome were a post-stenting MLD 16 mm, a balloon/vessel diameter ratio for final stent expansion <or = 1.00 and the presence of a dissection after balloon angioplasty. CONCLUSIONS: Compared with previous reports on stand-alone balloon angioplasty, stenting of nonacute total coronary occlusions lowers the 6-month restenosis/reocclusion rate to approximately 30%. The late procedural outcome is independently and statistically significantly influenced by the MLD after stenting, the length of the stented vessel segment, the balloon/vessel diameter ratio for final stent expansion and the incidence of dissections after balloon angioplasty.

AB - OBJECTIVES: This study was designed to determine and assess factors predictive of the intermediate-term outcome of stenting of nonacute total coronary occlusions. BACKGROUND: Balloon angioplasty of recanalized coronary occlusions is associated with a combined restenosis/reocclusion rate of up to 65%. Adjunctive stenting holds the potential to reduce this rate significantly. However, variables affecting the late angiographic outcome of coronary stenting in the setting of a total occlusion have not been elucidated sufficiently. METHODS: Coronary stenting was performed in 143 consecutive patients with a nonacute total occlusion; 120 of these patients (84%), with a total of 121 occlusions, underwent repeat angiography within 6 months and comprised the study group. High pressure stent implantation aimed to cover the site of the occlusion as well as adjacent diameter stenoses > or = 70% and all possibly induced dissections. Pertinent angiographic and procedural variables obtained at the time of the intervention were entered into a multivariate logistic regression analysis model to assess their influence on the angiographic outcome at follow-up. RESULTS: Mean preinterventional reference lumen diameter for the 121 vessels was 2.99 +/- 0.53 mm (mean +/- SD); occlusion length ranged from 4 to 44 mm (median of 7.7). After balloon angioplasty, dissections were found in 80% of patients. Lesions were covered with stents a median of 16 mm in length (range 8 to 53). The minimal lumen diameter (MLD) achieved after stenting was 2.89 +/- 0.48 mm. After a median follow-up period of 4.5 months, mean MLD was assessed at 1.91 +/- 0.90 mm, corresponding to a loss index of 0.34 +/- 0.31. There were 27 vessels with a nonocclusive restenosis > or = 50% and 8 with a reocclusion, for a combined restenosis/reocclusion rate of 29%. Factors found to adversely influence angiographic outcome were a post-stenting MLD 16 mm, a balloon/vessel diameter ratio for final stent expansion <or = 1.00 and the presence of a dissection after balloon angioplasty. CONCLUSIONS: Compared with previous reports on stand-alone balloon angioplasty, stenting of nonacute total coronary occlusions lowers the 6-month restenosis/reocclusion rate to approximately 30%. The late procedural outcome is independently and statistically significantly influenced by the MLD after stenting, the length of the stented vessel segment, the balloon/vessel diameter ratio for final stent expansion and the incidence of dissections after balloon angioplasty.

M3 - SCORING: Zeitschriftenaufsatz

VL - 31

SP - 275

EP - 280

JO - J AM COLL CARDIOL

JF - J AM COLL CARDIOL

SN - 0735-1097

IS - 2

M1 - 2

ER -