Segmented 2D-selective RF excitations with weighted averaging and flip angle adaptation for MR spectroscopy of irregularly shaped voxel.

Standard

Segmented 2D-selective RF excitations with weighted averaging and flip angle adaptation for MR spectroscopy of irregularly shaped voxel. / Finsterbusch, Jürgen; Busch, Martin.

in: MAGN RESON MED, Jahrgang 66, Nr. 2, 2, 2011, S. 333-340.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{98e3d14ded39413b881234b50a029c45,
title = "Segmented 2D-selective RF excitations with weighted averaging and flip angle adaptation for MR spectroscopy of irregularly shaped voxel.",
abstract = "A weighted averaging scheme with flip angle adaptation is presented for segmented 2D-selective RF excitations and applied to single-line segments of a blipped-planar trajectory. Segments covering the central k-space, i.e. those with significant signal contributions, are averaged more often than the (outer) segments with low RF amplitudes and minor signal contributions. For compensation, these outer segments are applied with an increased RF amplitude, i.e. a larger flip angle, such that an unaltered signal contribution is obtained in a reduced number of shots. Numerical simulations and experiments in phantoms and the human brain in vivo demonstrate that the approach considerably increases the signal efficiency, i.e. the signal accumulated per time unit, without introducing profile distortions. Its application to single-voxel MR spectroscopy of a corpus-callosum-shaped region-of-interest yielded, due to an optimum coverage of the target volume, higher signal amplitudes than conventional localization based on cross-sectional RF excitations. Thus, the approach could improve the reliability of single-voxel MR spectroscopy.",
keywords = "Humans, Reproducibility of Results, Sensitivity and Specificity, Data Interpretation, Statistical, Magnetic Resonance Imaging/*methods, Imaging, Three-Dimensional/*methods, *Algorithms, Magnetic Resonance Spectroscopy/*methods, Corpus Callosum/*chemistry, Humans, Reproducibility of Results, Sensitivity and Specificity, Data Interpretation, Statistical, Magnetic Resonance Imaging/*methods, Imaging, Three-Dimensional/*methods, *Algorithms, Magnetic Resonance Spectroscopy/*methods, Corpus Callosum/*chemistry",
author = "J{\"u}rgen Finsterbusch and Martin Busch",
year = "2011",
language = "English",
volume = "66",
pages = "333--340",
journal = "MAGN RESON MED",
issn = "0740-3194",
publisher = "John Wiley and Sons Inc.",
number = "2",

}

RIS

TY - JOUR

T1 - Segmented 2D-selective RF excitations with weighted averaging and flip angle adaptation for MR spectroscopy of irregularly shaped voxel.

AU - Finsterbusch, Jürgen

AU - Busch, Martin

PY - 2011

Y1 - 2011

N2 - A weighted averaging scheme with flip angle adaptation is presented for segmented 2D-selective RF excitations and applied to single-line segments of a blipped-planar trajectory. Segments covering the central k-space, i.e. those with significant signal contributions, are averaged more often than the (outer) segments with low RF amplitudes and minor signal contributions. For compensation, these outer segments are applied with an increased RF amplitude, i.e. a larger flip angle, such that an unaltered signal contribution is obtained in a reduced number of shots. Numerical simulations and experiments in phantoms and the human brain in vivo demonstrate that the approach considerably increases the signal efficiency, i.e. the signal accumulated per time unit, without introducing profile distortions. Its application to single-voxel MR spectroscopy of a corpus-callosum-shaped region-of-interest yielded, due to an optimum coverage of the target volume, higher signal amplitudes than conventional localization based on cross-sectional RF excitations. Thus, the approach could improve the reliability of single-voxel MR spectroscopy.

AB - A weighted averaging scheme with flip angle adaptation is presented for segmented 2D-selective RF excitations and applied to single-line segments of a blipped-planar trajectory. Segments covering the central k-space, i.e. those with significant signal contributions, are averaged more often than the (outer) segments with low RF amplitudes and minor signal contributions. For compensation, these outer segments are applied with an increased RF amplitude, i.e. a larger flip angle, such that an unaltered signal contribution is obtained in a reduced number of shots. Numerical simulations and experiments in phantoms and the human brain in vivo demonstrate that the approach considerably increases the signal efficiency, i.e. the signal accumulated per time unit, without introducing profile distortions. Its application to single-voxel MR spectroscopy of a corpus-callosum-shaped region-of-interest yielded, due to an optimum coverage of the target volume, higher signal amplitudes than conventional localization based on cross-sectional RF excitations. Thus, the approach could improve the reliability of single-voxel MR spectroscopy.

KW - Humans

KW - Reproducibility of Results

KW - Sensitivity and Specificity

KW - Data Interpretation, Statistical

KW - Magnetic Resonance Imaging/methods

KW - Imaging, Three-Dimensional/methods

KW - Algorithms

KW - Magnetic Resonance Spectroscopy/methods

KW - Corpus Callosum/chemistry

KW - Humans

KW - Reproducibility of Results

KW - Sensitivity and Specificity

KW - Data Interpretation, Statistical

KW - Magnetic Resonance Imaging/methods

KW - Imaging, Three-Dimensional/methods

KW - Algorithms

KW - Magnetic Resonance Spectroscopy/methods

KW - Corpus Callosum/chemistry

M3 - SCORING: Journal article

VL - 66

SP - 333

EP - 340

JO - MAGN RESON MED

JF - MAGN RESON MED

SN - 0740-3194

IS - 2

M1 - 2