Screw fixation in stemless shoulder arthroplasty for the treatment of primary osteoarthritis leads to less osteolysis when compared to impaction fixation
Standard
Screw fixation in stemless shoulder arthroplasty for the treatment of primary osteoarthritis leads to less osteolysis when compared to impaction fixation. / Alikhah, Arad; Imiolczyk, Jan-Philipp; Krukenberg, Anna; Scheibel, Markus.
in: BMC MUSCULOSKEL DIS, Jahrgang 21, 295, 2020.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Screw fixation in stemless shoulder arthroplasty for the treatment of primary osteoarthritis leads to less osteolysis when compared to impaction fixation
AU - Alikhah, Arad
AU - Imiolczyk, Jan-Philipp
AU - Krukenberg, Anna
AU - Scheibel, Markus
PY - 2020
Y1 - 2020
N2 - BackgroundStemless total shoulder arthroplasty is a well-established and reliable surgical treatment option for glenohumeral osteoarthritis resulting in loss of pain and improvement of shoulder function. Currently the two methods for the fixation of the humeral component are either screw fixation or impaction. The purpose of this study is the clinical and radiological comparison of two different stemless designs (screw fixation vs impaction) for total shoulder arthroplasties in patients suffering from primary glenohumeral osteoarthritis.MethodsA retrospective cohort study including 39 patients with a mean age of 67 years and a minimum follow-up of 2 years was performed. Patients were separated into two groups based on the selected implant. In group A (n = 18) a screw fixation design and in group B (n = 21) an impaction type design was used. For clinical examination the Constant-Murley-Score (CS) and Subjective-Shoulder-Value (SSV) were evaluated. Radiological examination was performed on true-AP, axial and Y-view radiographs.ResultsIn group A the CS increased from 27.1 to 65.2 points and SSV from 27.3 to 76.7% (p < 0.05). No osteolysis of the medial calcar or subsidence of the humeral implant were found in this group. In group B the CS increased from 29.0 to 72.6 points and SSV from 33.1 to 85% (p < 0.05). Osteolysis of the medial calcar was present in seven patients in this group. No signs for humeral loosening were found in both groups.ConclusionImpaction and screw fixation total shoulder arthroplasty for primary glenohumeral osteoarthritis using a stemless device provide reliable clinical results. The screw fixation seems to prevent osteolysis of the medial calcar.
AB - BackgroundStemless total shoulder arthroplasty is a well-established and reliable surgical treatment option for glenohumeral osteoarthritis resulting in loss of pain and improvement of shoulder function. Currently the two methods for the fixation of the humeral component are either screw fixation or impaction. The purpose of this study is the clinical and radiological comparison of two different stemless designs (screw fixation vs impaction) for total shoulder arthroplasties in patients suffering from primary glenohumeral osteoarthritis.MethodsA retrospective cohort study including 39 patients with a mean age of 67 years and a minimum follow-up of 2 years was performed. Patients were separated into two groups based on the selected implant. In group A (n = 18) a screw fixation design and in group B (n = 21) an impaction type design was used. For clinical examination the Constant-Murley-Score (CS) and Subjective-Shoulder-Value (SSV) were evaluated. Radiological examination was performed on true-AP, axial and Y-view radiographs.ResultsIn group A the CS increased from 27.1 to 65.2 points and SSV from 27.3 to 76.7% (p < 0.05). No osteolysis of the medial calcar or subsidence of the humeral implant were found in this group. In group B the CS increased from 29.0 to 72.6 points and SSV from 33.1 to 85% (p < 0.05). Osteolysis of the medial calcar was present in seven patients in this group. No signs for humeral loosening were found in both groups.ConclusionImpaction and screw fixation total shoulder arthroplasty for primary glenohumeral osteoarthritis using a stemless device provide reliable clinical results. The screw fixation seems to prevent osteolysis of the medial calcar.