Scanning laser polarimetry and spectral domain optical coherence tomography for the detection of retinal changes in Parkinson's disease

Standard

Scanning laser polarimetry and spectral domain optical coherence tomography for the detection of retinal changes in Parkinson's disease. / Stemplewitz, Birthe; Keserü, Matthias; Bittersohl, Diana; Buhmann, Carsten; Skevas, Christos; Richard, Gisbert; Hassenstein, Andrea.

in: ACTA OPHTHALMOL, Jahrgang 93, Nr. 8, 12.2015, S. e672-7.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{c0371c037edf4282a5b23a3393930b6b,
title = "Scanning laser polarimetry and spectral domain optical coherence tomography for the detection of retinal changes in Parkinson's disease",
abstract = "PURPOSE: Whether retinal degeneration is part of the degenerative processes in patients with Parkinson's disease (PD) is still unclear. This cross-sectional study was undertaken to compare the retinal morphology of patients with PD and healthy controls using spectral domain optical coherence tomography (SD-OCT) and scanning laser polarimetry (SLP).METHODS: Both eyes of patients with PD (n = 108) and healthy controls (n = 165) were examined using SD-OCT and SLP on the same day. Data on the thickness of the retinal nerve fibre layer (RNFL) of all quadrants and the macular area were acquired by OCT (Cirrus, Zeiss). The SLP device (Glaucoma diagnostics (GDx), Zeiss) measured the RNFL and calculated the nerve fibre index (NFI). All patients and probands were checked for concomitant ocular disorders by an ophthalmologist. Visual acuity, intraocular pressure (IOP), objective refraction and the anterior and posterior segment were assessed.RESULTS: Patients with PD showed a reduced macular volume and a reduced central subfield thickness in OCT examinations. The RNFL in the different quadrants did not differ significantly from that of controls. SLP data showed a reduced average RNFL thickness, a decreased thickness of the inferior quadrant and an increase of the NFI in patients with PD.CONCLUSION: PD may be associated with reduced thickness and volume of the macula and a reduced thickness of the RNFL in the inferior quadrant of the retina. Investigations using SD-OCT and SLP revealed distinct but significant differences between patients with PD and healthy controls.",
author = "Birthe Stemplewitz and Matthias Keser{\"u} and Diana Bittersohl and Carsten Buhmann and Christos Skevas and Gisbert Richard and Andrea Hassenstein",
note = "{\textcopyright} 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.",
year = "2015",
month = dec,
doi = "10.1111/aos.12764",
language = "English",
volume = "93",
pages = "e672--7",
journal = "ACTA OPHTHALMOL",
issn = "1755-375X",
publisher = "Wiley-Blackwell",
number = "8",

}

RIS

TY - JOUR

T1 - Scanning laser polarimetry and spectral domain optical coherence tomography for the detection of retinal changes in Parkinson's disease

AU - Stemplewitz, Birthe

AU - Keserü, Matthias

AU - Bittersohl, Diana

AU - Buhmann, Carsten

AU - Skevas, Christos

AU - Richard, Gisbert

AU - Hassenstein, Andrea

N1 - © 2015 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

PY - 2015/12

Y1 - 2015/12

N2 - PURPOSE: Whether retinal degeneration is part of the degenerative processes in patients with Parkinson's disease (PD) is still unclear. This cross-sectional study was undertaken to compare the retinal morphology of patients with PD and healthy controls using spectral domain optical coherence tomography (SD-OCT) and scanning laser polarimetry (SLP).METHODS: Both eyes of patients with PD (n = 108) and healthy controls (n = 165) were examined using SD-OCT and SLP on the same day. Data on the thickness of the retinal nerve fibre layer (RNFL) of all quadrants and the macular area were acquired by OCT (Cirrus, Zeiss). The SLP device (Glaucoma diagnostics (GDx), Zeiss) measured the RNFL and calculated the nerve fibre index (NFI). All patients and probands were checked for concomitant ocular disorders by an ophthalmologist. Visual acuity, intraocular pressure (IOP), objective refraction and the anterior and posterior segment were assessed.RESULTS: Patients with PD showed a reduced macular volume and a reduced central subfield thickness in OCT examinations. The RNFL in the different quadrants did not differ significantly from that of controls. SLP data showed a reduced average RNFL thickness, a decreased thickness of the inferior quadrant and an increase of the NFI in patients with PD.CONCLUSION: PD may be associated with reduced thickness and volume of the macula and a reduced thickness of the RNFL in the inferior quadrant of the retina. Investigations using SD-OCT and SLP revealed distinct but significant differences between patients with PD and healthy controls.

AB - PURPOSE: Whether retinal degeneration is part of the degenerative processes in patients with Parkinson's disease (PD) is still unclear. This cross-sectional study was undertaken to compare the retinal morphology of patients with PD and healthy controls using spectral domain optical coherence tomography (SD-OCT) and scanning laser polarimetry (SLP).METHODS: Both eyes of patients with PD (n = 108) and healthy controls (n = 165) were examined using SD-OCT and SLP on the same day. Data on the thickness of the retinal nerve fibre layer (RNFL) of all quadrants and the macular area were acquired by OCT (Cirrus, Zeiss). The SLP device (Glaucoma diagnostics (GDx), Zeiss) measured the RNFL and calculated the nerve fibre index (NFI). All patients and probands were checked for concomitant ocular disorders by an ophthalmologist. Visual acuity, intraocular pressure (IOP), objective refraction and the anterior and posterior segment were assessed.RESULTS: Patients with PD showed a reduced macular volume and a reduced central subfield thickness in OCT examinations. The RNFL in the different quadrants did not differ significantly from that of controls. SLP data showed a reduced average RNFL thickness, a decreased thickness of the inferior quadrant and an increase of the NFI in patients with PD.CONCLUSION: PD may be associated with reduced thickness and volume of the macula and a reduced thickness of the RNFL in the inferior quadrant of the retina. Investigations using SD-OCT and SLP revealed distinct but significant differences between patients with PD and healthy controls.

U2 - 10.1111/aos.12764

DO - 10.1111/aos.12764

M3 - SCORING: Journal article

C2 - 26066643

VL - 93

SP - e672-7

JO - ACTA OPHTHALMOL

JF - ACTA OPHTHALMOL

SN - 1755-375X

IS - 8

ER -