Results of the Stent-Protected Angioplasty versus Carotid Endarterectomy (SPACE) study to treat symptomatic stenoses at 2 years: a multinational, prospective, randomised trial.
Standard
Results of the Stent-Protected Angioplasty versus Carotid Endarterectomy (SPACE) study to treat symptomatic stenoses at 2 years: a multinational, prospective, randomised trial. / Eckstein, Hans-Henning; Ringleb, Peter; Allenberg, Jens-Rainer; Berger, Jürgen; Fraedrich, Gustav; Hacke, Werner; Hennerici, Michael; Stingele, Robert; Fiehler, Jens; Zeumer, Hermann; Jansen, Olav.
in: LANCET NEUROL, Jahrgang 7, Nr. 10, 10, 2008, S. 893-902.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Results of the Stent-Protected Angioplasty versus Carotid Endarterectomy (SPACE) study to treat symptomatic stenoses at 2 years: a multinational, prospective, randomised trial.
AU - Eckstein, Hans-Henning
AU - Ringleb, Peter
AU - Allenberg, Jens-Rainer
AU - Berger, Jürgen
AU - Fraedrich, Gustav
AU - Hacke, Werner
AU - Hennerici, Michael
AU - Stingele, Robert
AU - Fiehler, Jens
AU - Zeumer, Hermann
AU - Jansen, Olav
PY - 2008
Y1 - 2008
N2 - BACKGROUND: The SPACE trial is a multinational, prospective, randomised study to test the hypothesis that carotid artery stenting is not inferior to carotid endarterectomy for treating patients with severe symptomatic carotid artery stenosis. We did not prove non-inferiority of carotid artery stenting compared with carotid endarterectomy for the 30-day complication rate, and we now report the results at 2 years. METHODS: Between March, 2001, and February, 2006, patients with symptomatic, severe (>or=70%) carotid artery stenosis were recruited to this non-inferiority trial and randomly assigned with a block randomisation design to have carotid artery angioplasty with stenting or carotid artery endarterectomy. 2-year endpoints include several clinical endpoints and the incidence of recurrent carotid stenosis of at least 70%. Clinical and vascular follow-up was done by a certified neurologist. Analyses were by intention to treat and per protocol. This trial is registered with ISRCTN, number 57874028.12. FINDINGS: 1 214 patients were randomly assigned (613 were randomly assigned to carotid angioplasty with stenting and 601 were randomly assigned to carotid endarterectomy). In both the intention-to-treat and per-protocol analyses the Kaplan-Meier estimates of ipsilateral ischaemic strokes up to 2 years after the procedure and any periprocedural stroke or death do not differ between the carotid artery stenting and the carotid endarterectomy groups (intention to treat 9.5%vs 8.8%; hazard ratio (HR) 1.10, 95%CI 0.75 to 1.61; log-rank p=0.62; per protocol 9.4%vs 7.8%; HR 1.23, 95%CI 0.82 to 1.83; log-rank p=0.31). In both the intention-to-treat and per-protocol populations, recurrent stenosis of 70% or more is significantly more frequent in the carotid artery stenting group compared with the carotid endarterectomy group, with a life-table estimate of 10.7% versus 4.6% (p=0.0009) and 11.1% versus 4.6% (p=0.0007), respectively. Only two incidences of recurrent stenoses after carotid artery stenting led to neurological symptoms. INTERPRETATION: After 2 years' follow-up, the rate of recurrent ipsilateral ischaemic strokes reported in the SPACE trial is similar for both treatment groups. The incidence of recurrent carotid stenosis at 2 years, as defined by ultrasound, is significantly higher after carotid artery stenting. However, it cannot be excluded that the degree of in-stent stenosis is slightly overestimated by conventional ultrasound criteria.
AB - BACKGROUND: The SPACE trial is a multinational, prospective, randomised study to test the hypothesis that carotid artery stenting is not inferior to carotid endarterectomy for treating patients with severe symptomatic carotid artery stenosis. We did not prove non-inferiority of carotid artery stenting compared with carotid endarterectomy for the 30-day complication rate, and we now report the results at 2 years. METHODS: Between March, 2001, and February, 2006, patients with symptomatic, severe (>or=70%) carotid artery stenosis were recruited to this non-inferiority trial and randomly assigned with a block randomisation design to have carotid artery angioplasty with stenting or carotid artery endarterectomy. 2-year endpoints include several clinical endpoints and the incidence of recurrent carotid stenosis of at least 70%. Clinical and vascular follow-up was done by a certified neurologist. Analyses were by intention to treat and per protocol. This trial is registered with ISRCTN, number 57874028.12. FINDINGS: 1 214 patients were randomly assigned (613 were randomly assigned to carotid angioplasty with stenting and 601 were randomly assigned to carotid endarterectomy). In both the intention-to-treat and per-protocol analyses the Kaplan-Meier estimates of ipsilateral ischaemic strokes up to 2 years after the procedure and any periprocedural stroke or death do not differ between the carotid artery stenting and the carotid endarterectomy groups (intention to treat 9.5%vs 8.8%; hazard ratio (HR) 1.10, 95%CI 0.75 to 1.61; log-rank p=0.62; per protocol 9.4%vs 7.8%; HR 1.23, 95%CI 0.82 to 1.83; log-rank p=0.31). In both the intention-to-treat and per-protocol populations, recurrent stenosis of 70% or more is significantly more frequent in the carotid artery stenting group compared with the carotid endarterectomy group, with a life-table estimate of 10.7% versus 4.6% (p=0.0009) and 11.1% versus 4.6% (p=0.0007), respectively. Only two incidences of recurrent stenoses after carotid artery stenting led to neurological symptoms. INTERPRETATION: After 2 years' follow-up, the rate of recurrent ipsilateral ischaemic strokes reported in the SPACE trial is similar for both treatment groups. The incidence of recurrent carotid stenosis at 2 years, as defined by ultrasound, is significantly higher after carotid artery stenting. However, it cannot be excluded that the degree of in-stent stenosis is slightly overestimated by conventional ultrasound criteria.
M3 - SCORING: Zeitschriftenaufsatz
VL - 7
SP - 893
EP - 902
JO - LANCET NEUROL
JF - LANCET NEUROL
SN - 1474-4422
IS - 10
M1 - 10
ER -