Reliability of cortical lesion detection on double inversion recovery MRI applying the MAGNIMS-Criteria in multiple sclerosis patients within a 16-months period

Standard

Reliability of cortical lesion detection on double inversion recovery MRI applying the MAGNIMS-Criteria in multiple sclerosis patients within a 16-months period. / Faizy, Tobias; Thaler, Christian; Ceyrowski, Tim; Broocks, Gabriel; Treffler, Natascha; Sedlacik, Jan; Stürner, Klarissa Hanja; Stellmann, Jan-Patrick; Heesen, Christoph; Fiehler, Jens; Siemonsen, Susanne.

in: PLOS ONE, Jahrgang 12, Nr. 2, 24.02.2017, S. e0172923.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{980cb93fd0dd40c48c9279f9db8501ab,
title = "Reliability of cortical lesion detection on double inversion recovery MRI applying the MAGNIMS-Criteria in multiple sclerosis patients within a 16-months period",
abstract = "PURPOSE: In patients with multiple sclerosis (MS), Double Inversion Recovery (DIR) magnetic resonance imaging (MRI) can be used to identify cortical lesions (CL). We sought to evaluate the reliability of CL detection on DIR longitudinally at multiple subsequent time-points applying the MAGNIMs scoring criteria for CLs.METHODS: 26 MS patients received a 3T-MRI (Siemens, Skyra) with DIR at 12 time-points (TP) within a 16 months period. Scans were assessed in random order by two different raters. Both raters separately marked all CLs on each scan and total lesion numbers were obtained for each scan-TP and patient. After a retrospective re-evaluation, the number of consensus CLs (conL) was defined as the total number of CLs, which both raters finally agreed on. CLs volumes, relative signal intensities and CLs localizations were determined. Both ratings (conL vs. non-consensus scoring) were compared for further analysis.RESULTS: A total number of n = 334 CLs were identified by both raters in 26 MS patients with a first agreement of both raters on 160 out of 334 of the CLs found (κ = 0.48). After the retrospective re-evaluation, consensus agreement increased to 233 out of 334 CL (κ = 0.69). 93.8% of conL were visible in at least 2 consecutive TP. 74.7% of the conL were visible in all 12 consecutive TP. ConL had greater mean lesion volumes and higher mean signal intensities compared to lesions that were only detected by one of the raters (p<0.05). A higher number of CLs in the frontal, parietal, temporal and occipital lobe were identified by both raters than the number of those only identified by one of the raters (p<0.05).CONCLUSIONS: After a first assessment, slightly less than a half of the CL were considered as reliably detectable on longitudinal DIR images. A retrospective re-evaluation notably increased the consensus agreement. However, this finding is narrowed, considering the fact that retrospective evaluation steps might not be practicable in clinical routine. Lesions that were not reliably identifiable by both raters seem to be characterized by lower signal intensity and smaller size, or located in distinct anatomical brain regions.",
keywords = "Adult, Cerebral Cortex/pathology, Female, Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging/methods, Male, Middle Aged, Multiple Sclerosis, Relapsing-Remitting/diagnostic imaging, Reproducibility of Results, Retrospective Studies, Young Adult",
author = "Tobias Faizy and Christian Thaler and Tim Ceyrowski and Gabriel Broocks and Natascha Treffler and Jan Sedlacik and St{\"u}rner, {Klarissa Hanja} and Jan-Patrick Stellmann and Christoph Heesen and Jens Fiehler and Susanne Siemonsen",
year = "2017",
month = feb,
day = "24",
doi = "10.1371/journal.pone.0172923",
language = "English",
volume = "12",
pages = "e0172923",
journal = "PLOS ONE",
issn = "1932-6203",
publisher = "Public Library of Science",
number = "2",

}

RIS

TY - JOUR

T1 - Reliability of cortical lesion detection on double inversion recovery MRI applying the MAGNIMS-Criteria in multiple sclerosis patients within a 16-months period

AU - Faizy, Tobias

AU - Thaler, Christian

AU - Ceyrowski, Tim

AU - Broocks, Gabriel

AU - Treffler, Natascha

AU - Sedlacik, Jan

AU - Stürner, Klarissa Hanja

AU - Stellmann, Jan-Patrick

AU - Heesen, Christoph

AU - Fiehler, Jens

AU - Siemonsen, Susanne

PY - 2017/2/24

Y1 - 2017/2/24

N2 - PURPOSE: In patients with multiple sclerosis (MS), Double Inversion Recovery (DIR) magnetic resonance imaging (MRI) can be used to identify cortical lesions (CL). We sought to evaluate the reliability of CL detection on DIR longitudinally at multiple subsequent time-points applying the MAGNIMs scoring criteria for CLs.METHODS: 26 MS patients received a 3T-MRI (Siemens, Skyra) with DIR at 12 time-points (TP) within a 16 months period. Scans were assessed in random order by two different raters. Both raters separately marked all CLs on each scan and total lesion numbers were obtained for each scan-TP and patient. After a retrospective re-evaluation, the number of consensus CLs (conL) was defined as the total number of CLs, which both raters finally agreed on. CLs volumes, relative signal intensities and CLs localizations were determined. Both ratings (conL vs. non-consensus scoring) were compared for further analysis.RESULTS: A total number of n = 334 CLs were identified by both raters in 26 MS patients with a first agreement of both raters on 160 out of 334 of the CLs found (κ = 0.48). After the retrospective re-evaluation, consensus agreement increased to 233 out of 334 CL (κ = 0.69). 93.8% of conL were visible in at least 2 consecutive TP. 74.7% of the conL were visible in all 12 consecutive TP. ConL had greater mean lesion volumes and higher mean signal intensities compared to lesions that were only detected by one of the raters (p<0.05). A higher number of CLs in the frontal, parietal, temporal and occipital lobe were identified by both raters than the number of those only identified by one of the raters (p<0.05).CONCLUSIONS: After a first assessment, slightly less than a half of the CL were considered as reliably detectable on longitudinal DIR images. A retrospective re-evaluation notably increased the consensus agreement. However, this finding is narrowed, considering the fact that retrospective evaluation steps might not be practicable in clinical routine. Lesions that were not reliably identifiable by both raters seem to be characterized by lower signal intensity and smaller size, or located in distinct anatomical brain regions.

AB - PURPOSE: In patients with multiple sclerosis (MS), Double Inversion Recovery (DIR) magnetic resonance imaging (MRI) can be used to identify cortical lesions (CL). We sought to evaluate the reliability of CL detection on DIR longitudinally at multiple subsequent time-points applying the MAGNIMs scoring criteria for CLs.METHODS: 26 MS patients received a 3T-MRI (Siemens, Skyra) with DIR at 12 time-points (TP) within a 16 months period. Scans were assessed in random order by two different raters. Both raters separately marked all CLs on each scan and total lesion numbers were obtained for each scan-TP and patient. After a retrospective re-evaluation, the number of consensus CLs (conL) was defined as the total number of CLs, which both raters finally agreed on. CLs volumes, relative signal intensities and CLs localizations were determined. Both ratings (conL vs. non-consensus scoring) were compared for further analysis.RESULTS: A total number of n = 334 CLs were identified by both raters in 26 MS patients with a first agreement of both raters on 160 out of 334 of the CLs found (κ = 0.48). After the retrospective re-evaluation, consensus agreement increased to 233 out of 334 CL (κ = 0.69). 93.8% of conL were visible in at least 2 consecutive TP. 74.7% of the conL were visible in all 12 consecutive TP. ConL had greater mean lesion volumes and higher mean signal intensities compared to lesions that were only detected by one of the raters (p<0.05). A higher number of CLs in the frontal, parietal, temporal and occipital lobe were identified by both raters than the number of those only identified by one of the raters (p<0.05).CONCLUSIONS: After a first assessment, slightly less than a half of the CL were considered as reliably detectable on longitudinal DIR images. A retrospective re-evaluation notably increased the consensus agreement. However, this finding is narrowed, considering the fact that retrospective evaluation steps might not be practicable in clinical routine. Lesions that were not reliably identifiable by both raters seem to be characterized by lower signal intensity and smaller size, or located in distinct anatomical brain regions.

KW - Adult

KW - Cerebral Cortex/pathology

KW - Female

KW - Humans

KW - Image Processing, Computer-Assisted

KW - Magnetic Resonance Imaging/methods

KW - Male

KW - Middle Aged

KW - Multiple Sclerosis, Relapsing-Remitting/diagnostic imaging

KW - Reproducibility of Results

KW - Retrospective Studies

KW - Young Adult

U2 - 10.1371/journal.pone.0172923

DO - 10.1371/journal.pone.0172923

M3 - SCORING: Journal article

C2 - 28235075

VL - 12

SP - e0172923

JO - PLOS ONE

JF - PLOS ONE

SN - 1932-6203

IS - 2

ER -