Rapid direct detection of pathogens for diagnosis of joint infections by MALDI-TOF MS after liquid enrichment in the BacT/Alert blood culture system

Standard

Rapid direct detection of pathogens for diagnosis of joint infections by MALDI-TOF MS after liquid enrichment in the BacT/Alert blood culture system. / Noll, Christine; Nasruddin-Yekta, Azadda; Sternisek, Pia; Weig, Michael; Groß, Uwe; Schilling, Arndt F; Beil, Frank Timo; Bader, Oliver.

in: PLOS ONE, Jahrgang 15, Nr. 12, 2020, S. e0243790.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{27373bd2b1f14e5da10e098e17005b12,
title = "Rapid direct detection of pathogens for diagnosis of joint infections by MALDI-TOF MS after liquid enrichment in the BacT/Alert blood culture system",
abstract = "Pathogen identification is a critical step during diagnosis of infectious diseases. Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight mass spectrometry (MALDI-TOF-MS) has become the gold standard for identification of microorganisms cultured on solid media in microbiology laboratories. Direct identification of microbes from liquid specimen, circumventing the need for the additional overnight cultivation step, has been successfully established for blood culture, urine and liquor. Here, we evaluate the ability of MALDI-TOF MS for direct identification of pathogens in synovial fluid after liquid enrichment in BacT/Alert blood culture bottles. Influence of synovial specimen quality on direct species identification with the MALDI BioTyper/Sepsityper was tested with samples inoculated from pretested native synovia with concomitant inoculation of blood or pus, or highly viscous fluid. Here, we achieved >90% concordance with culture on solid medium, and only mixed-species samples posed significant problems. Performance in routine diagnostics was tested prospectively on bottles inoculated by treating physicians on ward. There, we achieved >70% concordance with culture on solid media. The major contributors to test failure were the absence of a measurable mass signal and mixed-specimen samples. The Sepsityper workflow worked well on samples derived from BacT/Alert blood culture bottles inoculated with synovial fluid, giving concordant results to identification from solid media. Host remnant material in the inoculum, such as blood or pus, had no detrimental effect on identification score values of the BioTyper system after processing with the Sepsityper workflow, and neither had the initial viscosity of the synovial sample.",
author = "Christine Noll and Azadda Nasruddin-Yekta and Pia Sternisek and Michael Weig and Uwe Gro{\ss} and Schilling, {Arndt F} and Beil, {Frank Timo} and Oliver Bader",
year = "2020",
doi = "10.1371/journal.pone.0243790",
language = "English",
volume = "15",
pages = "e0243790",
journal = "PLOS ONE",
issn = "1932-6203",
publisher = "Public Library of Science",
number = "12",

}

RIS

TY - JOUR

T1 - Rapid direct detection of pathogens for diagnosis of joint infections by MALDI-TOF MS after liquid enrichment in the BacT/Alert blood culture system

AU - Noll, Christine

AU - Nasruddin-Yekta, Azadda

AU - Sternisek, Pia

AU - Weig, Michael

AU - Groß, Uwe

AU - Schilling, Arndt F

AU - Beil, Frank Timo

AU - Bader, Oliver

PY - 2020

Y1 - 2020

N2 - Pathogen identification is a critical step during diagnosis of infectious diseases. Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight mass spectrometry (MALDI-TOF-MS) has become the gold standard for identification of microorganisms cultured on solid media in microbiology laboratories. Direct identification of microbes from liquid specimen, circumventing the need for the additional overnight cultivation step, has been successfully established for blood culture, urine and liquor. Here, we evaluate the ability of MALDI-TOF MS for direct identification of pathogens in synovial fluid after liquid enrichment in BacT/Alert blood culture bottles. Influence of synovial specimen quality on direct species identification with the MALDI BioTyper/Sepsityper was tested with samples inoculated from pretested native synovia with concomitant inoculation of blood or pus, or highly viscous fluid. Here, we achieved >90% concordance with culture on solid medium, and only mixed-species samples posed significant problems. Performance in routine diagnostics was tested prospectively on bottles inoculated by treating physicians on ward. There, we achieved >70% concordance with culture on solid media. The major contributors to test failure were the absence of a measurable mass signal and mixed-specimen samples. The Sepsityper workflow worked well on samples derived from BacT/Alert blood culture bottles inoculated with synovial fluid, giving concordant results to identification from solid media. Host remnant material in the inoculum, such as blood or pus, had no detrimental effect on identification score values of the BioTyper system after processing with the Sepsityper workflow, and neither had the initial viscosity of the synovial sample.

AB - Pathogen identification is a critical step during diagnosis of infectious diseases. Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight mass spectrometry (MALDI-TOF-MS) has become the gold standard for identification of microorganisms cultured on solid media in microbiology laboratories. Direct identification of microbes from liquid specimen, circumventing the need for the additional overnight cultivation step, has been successfully established for blood culture, urine and liquor. Here, we evaluate the ability of MALDI-TOF MS for direct identification of pathogens in synovial fluid after liquid enrichment in BacT/Alert blood culture bottles. Influence of synovial specimen quality on direct species identification with the MALDI BioTyper/Sepsityper was tested with samples inoculated from pretested native synovia with concomitant inoculation of blood or pus, or highly viscous fluid. Here, we achieved >90% concordance with culture on solid medium, and only mixed-species samples posed significant problems. Performance in routine diagnostics was tested prospectively on bottles inoculated by treating physicians on ward. There, we achieved >70% concordance with culture on solid media. The major contributors to test failure were the absence of a measurable mass signal and mixed-specimen samples. The Sepsityper workflow worked well on samples derived from BacT/Alert blood culture bottles inoculated with synovial fluid, giving concordant results to identification from solid media. Host remnant material in the inoculum, such as blood or pus, had no detrimental effect on identification score values of the BioTyper system after processing with the Sepsityper workflow, and neither had the initial viscosity of the synovial sample.

U2 - 10.1371/journal.pone.0243790

DO - 10.1371/journal.pone.0243790

M3 - SCORING: Journal article

C2 - 33306699

VL - 15

SP - e0243790

JO - PLOS ONE

JF - PLOS ONE

SN - 1932-6203

IS - 12

ER -