Radiation dose reduction during transjugular intrahepatic portosystemic shunt implantation using a new imaging technology

Standard

Radiation dose reduction during transjugular intrahepatic portosystemic shunt implantation using a new imaging technology. / Spink, C; Avanesov, M; Schmidt, T; Grass, M; Schoen, G; Adam, G; Bannas, P; Koops, A.

in: EUR J RADIOL, Jahrgang 86, 01.2017, S. 284-288.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{14da9fa2ed84453f814f2b7a7fa3dec1,
title = "Radiation dose reduction during transjugular intrahepatic portosystemic shunt implantation using a new imaging technology",
abstract = "OBJECTIVE: To compare patient radiation dose in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) implantation before and after an imaging-processing technology upgrade.METHODS: In our retrospective single-center-study, cumulative air kerma (AK), cumulative dose area product (DAP), total fluoroscopy time and contrast agent were collected from an age- and BMI-matched collective of 108 patients undergoing TIPS implantation. 54 procedures were performed before and 54 after the technology upgrade. Mean values were calculated and compared using two-tailed t-tests. Two blinded, independent readers assessed DSA image quality using a four-rank likert scale and the Wilcoxcon test.RESULTS: The new technology demonstrated a significant reduction of 57% of mean DAP (402.8 vs. 173.3Gycm(2), p<0.001) and a significant reduction of 58% of mean AK (1.7 vs. 0.7Gy, p<0.001) compared to the precursor technology. Time of fluoroscopy (26.4 vs. 27.8min, p=0.45) and amount of contrast agent (109.4 vs. 114.9ml, p=0.62) did not differ significantly between the two groups. The DSA image quality of the new technology was not inferior (2.66 vs. 2.77, p=0.56).CONCLUSIONS: In our study the new imaging technology halved radiation dose in patients undergoing TIPS maintaining sufficient image quality without a significant increase in radiation time or contrast consumption.",
author = "C Spink and M Avanesov and T Schmidt and M Grass and G Schoen and G Adam and P Bannas and A Koops",
note = "Copyright {\textcopyright} 2016 Elsevier Ireland Ltd. All rights reserved.",
year = "2017",
month = jan,
doi = "10.1016/j.ejrad.2016.11.028",
language = "English",
volume = "86",
pages = "284--288",
journal = "EUR J RADIOL",
issn = "0720-048X",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - Radiation dose reduction during transjugular intrahepatic portosystemic shunt implantation using a new imaging technology

AU - Spink, C

AU - Avanesov, M

AU - Schmidt, T

AU - Grass, M

AU - Schoen, G

AU - Adam, G

AU - Bannas, P

AU - Koops, A

N1 - Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

PY - 2017/1

Y1 - 2017/1

N2 - OBJECTIVE: To compare patient radiation dose in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) implantation before and after an imaging-processing technology upgrade.METHODS: In our retrospective single-center-study, cumulative air kerma (AK), cumulative dose area product (DAP), total fluoroscopy time and contrast agent were collected from an age- and BMI-matched collective of 108 patients undergoing TIPS implantation. 54 procedures were performed before and 54 after the technology upgrade. Mean values were calculated and compared using two-tailed t-tests. Two blinded, independent readers assessed DSA image quality using a four-rank likert scale and the Wilcoxcon test.RESULTS: The new technology demonstrated a significant reduction of 57% of mean DAP (402.8 vs. 173.3Gycm(2), p<0.001) and a significant reduction of 58% of mean AK (1.7 vs. 0.7Gy, p<0.001) compared to the precursor technology. Time of fluoroscopy (26.4 vs. 27.8min, p=0.45) and amount of contrast agent (109.4 vs. 114.9ml, p=0.62) did not differ significantly between the two groups. The DSA image quality of the new technology was not inferior (2.66 vs. 2.77, p=0.56).CONCLUSIONS: In our study the new imaging technology halved radiation dose in patients undergoing TIPS maintaining sufficient image quality without a significant increase in radiation time or contrast consumption.

AB - OBJECTIVE: To compare patient radiation dose in patients undergoing transjugular intrahepatic portosystemic shunt (TIPS) implantation before and after an imaging-processing technology upgrade.METHODS: In our retrospective single-center-study, cumulative air kerma (AK), cumulative dose area product (DAP), total fluoroscopy time and contrast agent were collected from an age- and BMI-matched collective of 108 patients undergoing TIPS implantation. 54 procedures were performed before and 54 after the technology upgrade. Mean values were calculated and compared using two-tailed t-tests. Two blinded, independent readers assessed DSA image quality using a four-rank likert scale and the Wilcoxcon test.RESULTS: The new technology demonstrated a significant reduction of 57% of mean DAP (402.8 vs. 173.3Gycm(2), p<0.001) and a significant reduction of 58% of mean AK (1.7 vs. 0.7Gy, p<0.001) compared to the precursor technology. Time of fluoroscopy (26.4 vs. 27.8min, p=0.45) and amount of contrast agent (109.4 vs. 114.9ml, p=0.62) did not differ significantly between the two groups. The DSA image quality of the new technology was not inferior (2.66 vs. 2.77, p=0.56).CONCLUSIONS: In our study the new imaging technology halved radiation dose in patients undergoing TIPS maintaining sufficient image quality without a significant increase in radiation time or contrast consumption.

U2 - 10.1016/j.ejrad.2016.11.028

DO - 10.1016/j.ejrad.2016.11.028

M3 - SCORING: Journal article

C2 - 28027761

VL - 86

SP - 284

EP - 288

JO - EUR J RADIOL

JF - EUR J RADIOL

SN - 0720-048X

ER -