QFT-Plus: a plus in variability? - Evaluation of new generation IGRA in serial testing of students with a migration background in Germany

Standard

QFT-Plus: a plus in variability? - Evaluation of new generation IGRA in serial testing of students with a migration background in Germany. / Knierer, J; Gallegos Morales, E N; Schablon, A; Nienhaus, A; Kersten, J F.

in: J OCCUP MED TOXICOL, Jahrgang 12, 2017, S. 1.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{37ab5129ec3944da81494dbab7737a47,
title = "QFT-Plus: a plus in variability? - Evaluation of new generation IGRA in serial testing of students with a migration background in Germany",
abstract = "BACKGROUND: Currently available Interferon-gamma release assays (IGRAs) show a considerable variability in serial testing for latent tuberculosis infection (LTBI). This study offers first results for the new generation IGRA QuantiFERON-TB Gold Plus (QFT-Plus) introduced in 2015 in comparison with its predecessor QuantiFERON-TB Gold In-Tube (QFT-GIT) from serial testing of students with a migration background at German universities.METHODS: Forty-one students were selected from a previous study. All students with a positive IGRA were asked and 11 agreed to participate in this cohort study. Additionally 30 students with negative IGRA results were selected by chance. Weekly testing with QFT-Plus and QFT-GIT was performed in all individuals over a 4-week period. IGRA variability was evaluated by calculating conversion and reversion rates.RESULTS: From 41 participants a total number of 163 serial measurements were analyzed for each IGRA, leading to 122 possible IGRA changes each. QFT-Plus had four conversions and two reversions leading to a conversion rate of 4.3% (4 of 93 possible conversions, 95% CI 1.4-11.3%) and reversion rate of 6.9% (2 of 29 possible reversions, 95% CI 1.2-24.2%). QFT-GIT had 2 conversions and 1 reversion causing slightly lower rates with 2.2% conversions (2 of 91, 95% CI 0.4-8.5%) and 3.2% reversions (1 of 31, 95% CI 0.2-18.5%). Inconsistent IGRA results occurred in 4 subjects for QFT-Plus (8 stable positives, 29 stable negatives) and in 2 subjects for QFT-GIT (9 stable positives, 30 stable negatives). Agreement between the two IGRAs was 95.1% (κ = 0.89). Variance attributed to the individuals was low (QFT-Plus: ICC = 0.88).CONCLUSION: This study confirms occurrence of conversions and reversions for the new QFT-Plus in serial testing of a high-risk cohort in a low-incidence setting with improbable new TB contact during the study. QFT-Plus conversion and reversion rates were slightly higher than for the QFT-GIT but overall they were lower for both IGRAs than in other studies that investigated IGRA variability.",
author = "J Knierer and {Gallegos Morales}, {E N} and A Schablon and A Nienhaus and Kersten, {J F}",
year = "2017",
doi = "10.1186/s12995-016-0148-z",
language = "English",
volume = "12",
pages = "1",
journal = "J OCCUP MED TOXICOL",
issn = "1745-6673",
publisher = "BioMed Central Ltd.",

}

RIS

TY - JOUR

T1 - QFT-Plus: a plus in variability? - Evaluation of new generation IGRA in serial testing of students with a migration background in Germany

AU - Knierer, J

AU - Gallegos Morales, E N

AU - Schablon, A

AU - Nienhaus, A

AU - Kersten, J F

PY - 2017

Y1 - 2017

N2 - BACKGROUND: Currently available Interferon-gamma release assays (IGRAs) show a considerable variability in serial testing for latent tuberculosis infection (LTBI). This study offers first results for the new generation IGRA QuantiFERON-TB Gold Plus (QFT-Plus) introduced in 2015 in comparison with its predecessor QuantiFERON-TB Gold In-Tube (QFT-GIT) from serial testing of students with a migration background at German universities.METHODS: Forty-one students were selected from a previous study. All students with a positive IGRA were asked and 11 agreed to participate in this cohort study. Additionally 30 students with negative IGRA results were selected by chance. Weekly testing with QFT-Plus and QFT-GIT was performed in all individuals over a 4-week period. IGRA variability was evaluated by calculating conversion and reversion rates.RESULTS: From 41 participants a total number of 163 serial measurements were analyzed for each IGRA, leading to 122 possible IGRA changes each. QFT-Plus had four conversions and two reversions leading to a conversion rate of 4.3% (4 of 93 possible conversions, 95% CI 1.4-11.3%) and reversion rate of 6.9% (2 of 29 possible reversions, 95% CI 1.2-24.2%). QFT-GIT had 2 conversions and 1 reversion causing slightly lower rates with 2.2% conversions (2 of 91, 95% CI 0.4-8.5%) and 3.2% reversions (1 of 31, 95% CI 0.2-18.5%). Inconsistent IGRA results occurred in 4 subjects for QFT-Plus (8 stable positives, 29 stable negatives) and in 2 subjects for QFT-GIT (9 stable positives, 30 stable negatives). Agreement between the two IGRAs was 95.1% (κ = 0.89). Variance attributed to the individuals was low (QFT-Plus: ICC = 0.88).CONCLUSION: This study confirms occurrence of conversions and reversions for the new QFT-Plus in serial testing of a high-risk cohort in a low-incidence setting with improbable new TB contact during the study. QFT-Plus conversion and reversion rates were slightly higher than for the QFT-GIT but overall they were lower for both IGRAs than in other studies that investigated IGRA variability.

AB - BACKGROUND: Currently available Interferon-gamma release assays (IGRAs) show a considerable variability in serial testing for latent tuberculosis infection (LTBI). This study offers first results for the new generation IGRA QuantiFERON-TB Gold Plus (QFT-Plus) introduced in 2015 in comparison with its predecessor QuantiFERON-TB Gold In-Tube (QFT-GIT) from serial testing of students with a migration background at German universities.METHODS: Forty-one students were selected from a previous study. All students with a positive IGRA were asked and 11 agreed to participate in this cohort study. Additionally 30 students with negative IGRA results were selected by chance. Weekly testing with QFT-Plus and QFT-GIT was performed in all individuals over a 4-week period. IGRA variability was evaluated by calculating conversion and reversion rates.RESULTS: From 41 participants a total number of 163 serial measurements were analyzed for each IGRA, leading to 122 possible IGRA changes each. QFT-Plus had four conversions and two reversions leading to a conversion rate of 4.3% (4 of 93 possible conversions, 95% CI 1.4-11.3%) and reversion rate of 6.9% (2 of 29 possible reversions, 95% CI 1.2-24.2%). QFT-GIT had 2 conversions and 1 reversion causing slightly lower rates with 2.2% conversions (2 of 91, 95% CI 0.4-8.5%) and 3.2% reversions (1 of 31, 95% CI 0.2-18.5%). Inconsistent IGRA results occurred in 4 subjects for QFT-Plus (8 stable positives, 29 stable negatives) and in 2 subjects for QFT-GIT (9 stable positives, 30 stable negatives). Agreement between the two IGRAs was 95.1% (κ = 0.89). Variance attributed to the individuals was low (QFT-Plus: ICC = 0.88).CONCLUSION: This study confirms occurrence of conversions and reversions for the new QFT-Plus in serial testing of a high-risk cohort in a low-incidence setting with improbable new TB contact during the study. QFT-Plus conversion and reversion rates were slightly higher than for the QFT-GIT but overall they were lower for both IGRAs than in other studies that investigated IGRA variability.

U2 - 10.1186/s12995-016-0148-z

DO - 10.1186/s12995-016-0148-z

M3 - SCORING: Journal article

C2 - 28070206

VL - 12

SP - 1

JO - J OCCUP MED TOXICOL

JF - J OCCUP MED TOXICOL

SN - 1745-6673