Pikosekundenlaser-Faser-assistierte Sklerostomie (PIRL-FAST): Ein erster Machbarkeitsnachweis
Standard
Pikosekundenlaser-Faser-assistierte Sklerostomie (PIRL-FAST): Ein erster Machbarkeitsnachweis. / Mehlan, J; Uschold, S; Hansen, N O; Gosau, T; Eggert, D; Spitzer, M; Petersen, H; Linke, S J; Miller, R J Dwayne.
in: OPHTHALMOLOGE, Jahrgang 116, Nr. 4, 04.2019, S. 346-350.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Pikosekundenlaser-Faser-assistierte Sklerostomie (PIRL-FAST): Ein erster Machbarkeitsnachweis
AU - Mehlan, J
AU - Uschold, S
AU - Hansen, N O
AU - Gosau, T
AU - Eggert, D
AU - Spitzer, M
AU - Petersen, H
AU - Linke, S J
AU - Miller, R J Dwayne
PY - 2019/4
Y1 - 2019/4
N2 - INTRODUCTION: The aim of this study was an analysis of the feasibility of a picosecond infrared laser fiber-assisted sclerostomy (PIRL-FAST) using a novel sapphire fiber and different energy levels of the picosecond laser.METHOD: The laser-assisted sclerostomy was carried out with a newly generated sapphire fiber of the PIRL-HP2-1064 OPA-3000 (Attodyne, Canada). Immediately after the intervention, the eyes were fixed in phosphate-buffered 3.5% formaldehyde. For subsequent histological analysis the eyes were cut into 4 μm thick sections and stained with hematoxylin and eosin (H&E, Merck, Darmstadt, Germany). All preparations were then scanned and digitalized using the MIRAX SCAN (Carl Zeiss Microimaging GmbH, Jena, Germany).RESULTS: The pulse energies 150 μJ (N = 4), 175 μJ (N = 6), 200 μJ (N = 7) and 250 μJ (N = 6) were selected. Within the framework of this first feasibility analysis 400 μm (10 sequential sections) of the sclerotomies were evaluated. The mean area of PIRL-FAST showed a dependency on the pulse energy applied. The diameter of the collateral damage zone (CDZ) depended on the pulse energy used. The largest CDZ could be measured using the highest pulse energy in this experiment (250 μJ). The environmental scanning electron microscope (ESEM) results revealed circular smooth sclerostomy wall with only minimal change of tissue ultrastructure.CONCLUSION: The PIRL-FAST using sapphire fibers is a new minimally invasive instrument to provide robust stenting from the anterior chamber to the subconjunctival space. Since the PIRL has proven to work efficiently in sectioning several tissues with minimal collateral damage these first proof of principle experiments might pave the way for a new minimally invasive glaucoma surgery strategy. We have already initiated experiments to analyze the wound healing and scar formation in vivo.
AB - INTRODUCTION: The aim of this study was an analysis of the feasibility of a picosecond infrared laser fiber-assisted sclerostomy (PIRL-FAST) using a novel sapphire fiber and different energy levels of the picosecond laser.METHOD: The laser-assisted sclerostomy was carried out with a newly generated sapphire fiber of the PIRL-HP2-1064 OPA-3000 (Attodyne, Canada). Immediately after the intervention, the eyes were fixed in phosphate-buffered 3.5% formaldehyde. For subsequent histological analysis the eyes were cut into 4 μm thick sections and stained with hematoxylin and eosin (H&E, Merck, Darmstadt, Germany). All preparations were then scanned and digitalized using the MIRAX SCAN (Carl Zeiss Microimaging GmbH, Jena, Germany).RESULTS: The pulse energies 150 μJ (N = 4), 175 μJ (N = 6), 200 μJ (N = 7) and 250 μJ (N = 6) were selected. Within the framework of this first feasibility analysis 400 μm (10 sequential sections) of the sclerotomies were evaluated. The mean area of PIRL-FAST showed a dependency on the pulse energy applied. The diameter of the collateral damage zone (CDZ) depended on the pulse energy used. The largest CDZ could be measured using the highest pulse energy in this experiment (250 μJ). The environmental scanning electron microscope (ESEM) results revealed circular smooth sclerostomy wall with only minimal change of tissue ultrastructure.CONCLUSION: The PIRL-FAST using sapphire fibers is a new minimally invasive instrument to provide robust stenting from the anterior chamber to the subconjunctival space. Since the PIRL has proven to work efficiently in sectioning several tissues with minimal collateral damage these first proof of principle experiments might pave the way for a new minimally invasive glaucoma surgery strategy. We have already initiated experiments to analyze the wound healing and scar formation in vivo.
KW - English Abstract
KW - Journal Article
U2 - 10.1007/s00347-018-0653-9
DO - 10.1007/s00347-018-0653-9
M3 - SCORING: Zeitschriftenaufsatz
C2 - 29387935
VL - 116
SP - 346
EP - 350
JO - OPHTHALMOLOGE
JF - OPHTHALMOLOGE
SN - 0941-293X
IS - 4
ER -