Peri-implant bone loss of dental implants with platform-switching design after 5 years of loading: a cross-sectional study

Standard

Peri-implant bone loss of dental implants with platform-switching design after 5 years of loading: a cross-sectional study. / Joda, Tim; Michelaki, Ioanna ; Heydecke, Guido.

in: QUINTESSENCE INT, Jahrgang 46, Nr. 1, 01.2015, S. 59-66.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{4073e315058d41d5b8f9d7ee2f9b6b75,
title = "Peri-implant bone loss of dental implants with platform-switching design after 5 years of loading: a cross-sectional study",
abstract = "OBJECTIVE: The aim of this cross-sectional study was to estimate bone loss of implants with platform-switching design and analyze possible risk indicators after 5 years of loading in a multi-centered private practice network.METHOD AND MATERIALS: Peri-implant bone loss was measured radiographically as the distance from the implant shoulder to the mesial and distal alveolar crest, respectively. Risk factor analysis for marginal bone loss included type of implant prosthetic treatment concept and dental status of the opposite arch.RESULTS: A total of 316 implants in 98 study patients after 5 years of loading were examined. The overall mean value for radiographic bone loss was 1.02 mm (SD ± 1.25 mm, 95% CI 0.90- 1.14). Correlation analyses indicated a strong association of peri-implant bone loss > 2 mm for removable implant-retained prostheses with an odds ratio of 53.8.CONCLUSION: The 5-year-results of the study show clinically acceptable values of mean bone loss after 5 years of loading. Implant-supported removable prostheses seem to be a strong co-factor for extensive bone level changes compared to fixed reconstructions. However, these results have to be considered for evaluation of the included special cohort under private dental office conditions.",
author = "Tim Joda and Ioanna Michelaki and Guido Heydecke",
year = "2015",
month = jan,
doi = "10.3290/j.qi.a32820",
language = "English",
volume = "46",
pages = "59--66",
journal = "QUINTESSENCE INT",
issn = "0033-6572",
publisher = "Quintessence Publishing Company",
number = "1",

}

RIS

TY - JOUR

T1 - Peri-implant bone loss of dental implants with platform-switching design after 5 years of loading: a cross-sectional study

AU - Joda, Tim

AU - Michelaki, Ioanna

AU - Heydecke, Guido

PY - 2015/1

Y1 - 2015/1

N2 - OBJECTIVE: The aim of this cross-sectional study was to estimate bone loss of implants with platform-switching design and analyze possible risk indicators after 5 years of loading in a multi-centered private practice network.METHOD AND MATERIALS: Peri-implant bone loss was measured radiographically as the distance from the implant shoulder to the mesial and distal alveolar crest, respectively. Risk factor analysis for marginal bone loss included type of implant prosthetic treatment concept and dental status of the opposite arch.RESULTS: A total of 316 implants in 98 study patients after 5 years of loading were examined. The overall mean value for radiographic bone loss was 1.02 mm (SD ± 1.25 mm, 95% CI 0.90- 1.14). Correlation analyses indicated a strong association of peri-implant bone loss > 2 mm for removable implant-retained prostheses with an odds ratio of 53.8.CONCLUSION: The 5-year-results of the study show clinically acceptable values of mean bone loss after 5 years of loading. Implant-supported removable prostheses seem to be a strong co-factor for extensive bone level changes compared to fixed reconstructions. However, these results have to be considered for evaluation of the included special cohort under private dental office conditions.

AB - OBJECTIVE: The aim of this cross-sectional study was to estimate bone loss of implants with platform-switching design and analyze possible risk indicators after 5 years of loading in a multi-centered private practice network.METHOD AND MATERIALS: Peri-implant bone loss was measured radiographically as the distance from the implant shoulder to the mesial and distal alveolar crest, respectively. Risk factor analysis for marginal bone loss included type of implant prosthetic treatment concept and dental status of the opposite arch.RESULTS: A total of 316 implants in 98 study patients after 5 years of loading were examined. The overall mean value for radiographic bone loss was 1.02 mm (SD ± 1.25 mm, 95% CI 0.90- 1.14). Correlation analyses indicated a strong association of peri-implant bone loss > 2 mm for removable implant-retained prostheses with an odds ratio of 53.8.CONCLUSION: The 5-year-results of the study show clinically acceptable values of mean bone loss after 5 years of loading. Implant-supported removable prostheses seem to be a strong co-factor for extensive bone level changes compared to fixed reconstructions. However, these results have to be considered for evaluation of the included special cohort under private dental office conditions.

U2 - 10.3290/j.qi.a32820

DO - 10.3290/j.qi.a32820

M3 - SCORING: Journal article

C2 - 25262678

VL - 46

SP - 59

EP - 66

JO - QUINTESSENCE INT

JF - QUINTESSENCE INT

SN - 0033-6572

IS - 1