Passende Verordnungsmenge und Applikation von Topika - Wie kann das richtige Volumen bei der Verordnung ermittelt werden?

Standard

Passende Verordnungsmenge und Applikation von Topika - Wie kann das richtige Volumen bei der Verordnung ermittelt werden? / Homayoon, D; Dahlhoff, Pia; Augustin, M.

in: HAUTARZT, Jahrgang 69, Nr. 6, 06.2018, S. 478-483.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ReviewForschung

Harvard

APA

Vancouver

Bibtex

@article{f84b21ec7a6040baa14170165b900d44,
title = "Passende Verordnungsmenge und Applikation von Topika - Wie kann das richtige Volumen bei der Verordnung ermittelt werden?",
abstract = "BACKGROUND: Uncertainty regarding the suitable amount of prescribed ointment and its application by patients may cause insufficient or uneconomic health care provision. To address this issue, standardized methods and experts' knowledge on the suitable amount and coherent patient's elucidation for application of topicals are needed.OBJECTIVES: Presented are current data in routine care and scientific evidence on the prescribed amount of topical agents as well as its application by patients in dermatological care.MATERIALS AND METHODS: A literature review was conducted via PubMed using the keywords as individual and pooled search terms: {"}local therapy{"}, {"}topical treatment{"}, {"}prescription{"}, {"}amount of ointment needed{"}, {"}involved area{"}, {"}BSA{"}, {"}finger-tip-unit{"}, {"}Rule of Hand{"}, {"}calculated dosage{"} and {"}rule of nines{"}. We included original studies by manually screening title and abstract according to the relevance of the topic.RESULTS: The search strategy identified 19 clinical trials. The fingertip unit (FTU) is the most frequently used measurement for accurate application of external agents. Appropriate prescribed amount is calculated by required topical agent per involved surface area.CONCLUSIONS: There is still a need for clarification to which extent the optimized amount of ointment is prescribed and advice for its application in routine care is given. The FTU combined with the {"}Rule of Hand{"} is an adequate measurement for patient's guidance on self-application.",
keywords = "English Abstract, Journal Article, Review",
author = "D Homayoon and Pia Dahlhoff and M Augustin",
note = "Bitte werten Sie Frau Dahlhoff als interne Person, da sie als Studentin hier gearbeitet hat. ",
year = "2018",
month = jun,
doi = "10.1007/s00105-017-4088-z",
language = "Deutsch",
volume = "69",
pages = "478--483",
journal = "HAUTARZT",
issn = "0017-8470",
publisher = "Springer",
number = "6",

}

RIS

TY - JOUR

T1 - Passende Verordnungsmenge und Applikation von Topika - Wie kann das richtige Volumen bei der Verordnung ermittelt werden?

AU - Homayoon, D

AU - Dahlhoff, Pia

AU - Augustin, M

N1 - Bitte werten Sie Frau Dahlhoff als interne Person, da sie als Studentin hier gearbeitet hat.

PY - 2018/6

Y1 - 2018/6

N2 - BACKGROUND: Uncertainty regarding the suitable amount of prescribed ointment and its application by patients may cause insufficient or uneconomic health care provision. To address this issue, standardized methods and experts' knowledge on the suitable amount and coherent patient's elucidation for application of topicals are needed.OBJECTIVES: Presented are current data in routine care and scientific evidence on the prescribed amount of topical agents as well as its application by patients in dermatological care.MATERIALS AND METHODS: A literature review was conducted via PubMed using the keywords as individual and pooled search terms: "local therapy", "topical treatment", "prescription", "amount of ointment needed", "involved area", "BSA", "finger-tip-unit", "Rule of Hand", "calculated dosage" and "rule of nines". We included original studies by manually screening title and abstract according to the relevance of the topic.RESULTS: The search strategy identified 19 clinical trials. The fingertip unit (FTU) is the most frequently used measurement for accurate application of external agents. Appropriate prescribed amount is calculated by required topical agent per involved surface area.CONCLUSIONS: There is still a need for clarification to which extent the optimized amount of ointment is prescribed and advice for its application in routine care is given. The FTU combined with the "Rule of Hand" is an adequate measurement for patient's guidance on self-application.

AB - BACKGROUND: Uncertainty regarding the suitable amount of prescribed ointment and its application by patients may cause insufficient or uneconomic health care provision. To address this issue, standardized methods and experts' knowledge on the suitable amount and coherent patient's elucidation for application of topicals are needed.OBJECTIVES: Presented are current data in routine care and scientific evidence on the prescribed amount of topical agents as well as its application by patients in dermatological care.MATERIALS AND METHODS: A literature review was conducted via PubMed using the keywords as individual and pooled search terms: "local therapy", "topical treatment", "prescription", "amount of ointment needed", "involved area", "BSA", "finger-tip-unit", "Rule of Hand", "calculated dosage" and "rule of nines". We included original studies by manually screening title and abstract according to the relevance of the topic.RESULTS: The search strategy identified 19 clinical trials. The fingertip unit (FTU) is the most frequently used measurement for accurate application of external agents. Appropriate prescribed amount is calculated by required topical agent per involved surface area.CONCLUSIONS: There is still a need for clarification to which extent the optimized amount of ointment is prescribed and advice for its application in routine care is given. The FTU combined with the "Rule of Hand" is an adequate measurement for patient's guidance on self-application.

KW - English Abstract

KW - Journal Article

KW - Review

U2 - 10.1007/s00105-017-4088-z

DO - 10.1007/s00105-017-4088-z

M3 - SCORING: Review

C2 - 29247255

VL - 69

SP - 478

EP - 483

JO - HAUTARZT

JF - HAUTARZT

SN - 0017-8470

IS - 6

ER -