Optische Kohärenztomographie in der Makuladiagnostik. Ubersicht der Methode und standardisierte Anwendung--Diagnostik und Therapiekontrolle der altersbedingten Makuladegeneration

Standard

Optische Kohärenztomographie in der Makuladiagnostik. Ubersicht der Methode und standardisierte Anwendung--Diagnostik und Therapiekontrolle der altersbedingten Makuladegeneration. / Hassenstein, A; Spital, G; Scholz, F; Henschel, A; Richard, G; Pauleikhoff, D.

in: OPHTHALMOLOGE, Jahrgang 106, Nr. 2, 01.02.2009, S. 116-26.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{ffd19f68f500460c909dc6f1ddda00a0,
title = "Optische Koh{\"a}renztomographie in der Makuladiagnostik. Ubersicht der Methode und standardisierte Anwendung--Diagnostik und Therapiekontrolle der altersbedingten Makuladegeneration",
abstract = "BACKGROUND: Optical coherence tomography (OCT) has gained increasing relevance for follow-up after the treatment of macular diseases especially after anti-VEGF therapy. Therefore it seemed reasonable to develop standardized evaluation strategies and OCT examination guidelines for Stratus OCT III.MATERIALS AND METHODS: Basic guidelines for the Stratus OCT III examination of macular diseases were developed. The first part contains basic advice for the OCT examination with respect to the examiner, patients, image quality, movement artefacts, algorithms, archiving and interpretation of OCT images. The second part consists of the relevance and indications for OCT examination especially in age-related macular degeneration (AMD), subgroups of AMD and follow-up after treatment. The third part demonstrates a brief outlook on future developments, such as the digital integration method (DIM), which provides identical scan localization in follow-up and eliminates any movement artefacts.CONCLUSION: The application of standardized routine scanning and analysis protocols in Stratus OCT III for macular diseases and follow-up examinations provides an optimized, time-saving and comparable use of OCT. Therefore, the relevance and quality of OCT is increased for routine use in outpatient departments, hospitals and also for clinical studies.",
keywords = "Germany, Humans, Macular Degeneration, Ophthalmoscopy, Practice Guidelines as Topic, Tomography, Optical Coherence",
author = "A Hassenstein and G Spital and F Scholz and A Henschel and G Richard and D Pauleikhoff",
year = "2009",
month = feb,
day = "1",
doi = "10.1007/s00347-008-1901-1",
language = "Deutsch",
volume = "106",
pages = "116--26",
journal = "OPHTHALMOLOGE",
issn = "0941-293X",
publisher = "Springer",
number = "2",

}

RIS

TY - JOUR

T1 - Optische Kohärenztomographie in der Makuladiagnostik. Ubersicht der Methode und standardisierte Anwendung--Diagnostik und Therapiekontrolle der altersbedingten Makuladegeneration

AU - Hassenstein, A

AU - Spital, G

AU - Scholz, F

AU - Henschel, A

AU - Richard, G

AU - Pauleikhoff, D

PY - 2009/2/1

Y1 - 2009/2/1

N2 - BACKGROUND: Optical coherence tomography (OCT) has gained increasing relevance for follow-up after the treatment of macular diseases especially after anti-VEGF therapy. Therefore it seemed reasonable to develop standardized evaluation strategies and OCT examination guidelines for Stratus OCT III.MATERIALS AND METHODS: Basic guidelines for the Stratus OCT III examination of macular diseases were developed. The first part contains basic advice for the OCT examination with respect to the examiner, patients, image quality, movement artefacts, algorithms, archiving and interpretation of OCT images. The second part consists of the relevance and indications for OCT examination especially in age-related macular degeneration (AMD), subgroups of AMD and follow-up after treatment. The third part demonstrates a brief outlook on future developments, such as the digital integration method (DIM), which provides identical scan localization in follow-up and eliminates any movement artefacts.CONCLUSION: The application of standardized routine scanning and analysis protocols in Stratus OCT III for macular diseases and follow-up examinations provides an optimized, time-saving and comparable use of OCT. Therefore, the relevance and quality of OCT is increased for routine use in outpatient departments, hospitals and also for clinical studies.

AB - BACKGROUND: Optical coherence tomography (OCT) has gained increasing relevance for follow-up after the treatment of macular diseases especially after anti-VEGF therapy. Therefore it seemed reasonable to develop standardized evaluation strategies and OCT examination guidelines for Stratus OCT III.MATERIALS AND METHODS: Basic guidelines for the Stratus OCT III examination of macular diseases were developed. The first part contains basic advice for the OCT examination with respect to the examiner, patients, image quality, movement artefacts, algorithms, archiving and interpretation of OCT images. The second part consists of the relevance and indications for OCT examination especially in age-related macular degeneration (AMD), subgroups of AMD and follow-up after treatment. The third part demonstrates a brief outlook on future developments, such as the digital integration method (DIM), which provides identical scan localization in follow-up and eliminates any movement artefacts.CONCLUSION: The application of standardized routine scanning and analysis protocols in Stratus OCT III for macular diseases and follow-up examinations provides an optimized, time-saving and comparable use of OCT. Therefore, the relevance and quality of OCT is increased for routine use in outpatient departments, hospitals and also for clinical studies.

KW - Germany

KW - Humans

KW - Macular Degeneration

KW - Ophthalmoscopy

KW - Practice Guidelines as Topic

KW - Tomography, Optical Coherence

U2 - 10.1007/s00347-008-1901-1

DO - 10.1007/s00347-008-1901-1

M3 - SCORING: Zeitschriftenaufsatz

C2 - 19156426

VL - 106

SP - 116

EP - 126

JO - OPHTHALMOLOGE

JF - OPHTHALMOLOGE

SN - 0941-293X

IS - 2

ER -