mpMRI of the Prostate (MR-Prostatography): Updated Recommendations of the DRG and BDR on Patient Preparation and Scanning Protocol
Standard
mpMRI of the Prostate (MR-Prostatography): Updated Recommendations of the DRG and BDR on Patient Preparation and Scanning Protocol. / Franiel, Tobias; Asbach, Patrick; Beyersdorff, Dirk; Blondin, Dirk; Kaufmann, Sascha; Mueller-Lisse, Ullrich Gerd; Quentin, Michael; Rödel, Stefan; Röthke, Matthias; Schlemmer, Heinz-Peter; Schimmöller, Lars; Vorstand der Deutschen Röntgengesellschaft e. V. (DRG).
in: ROFO-FORTSCHR RONTG, Jahrgang 193, Nr. 7, 07.2021, S. 763-777.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - mpMRI of the Prostate (MR-Prostatography): Updated Recommendations of the DRG and BDR on Patient Preparation and Scanning Protocol
AU - Franiel, Tobias
AU - Asbach, Patrick
AU - Beyersdorff, Dirk
AU - Blondin, Dirk
AU - Kaufmann, Sascha
AU - Mueller-Lisse, Ullrich Gerd
AU - Quentin, Michael
AU - Rödel, Stefan
AU - Röthke, Matthias
AU - Schlemmer, Heinz-Peter
AU - Schimmöller, Lars
AU - Vorstand der Deutschen Röntgengesellschaft e. V. (DRG)
N1 - Thieme. All rights reserved.
PY - 2021/7
Y1 - 2021/7
N2 - The Working Group Uroradiology and Urogenital Diagnosis of the German Roentgen Society (DRG) revised and updated the recommendations for preparation and scanning protocol of the multiparametric MRI of the Prostate in a consensus process and harmonized it with the managing board of German Roentgen Society and Professional Association of the German Radiologist (BDR e. V.). These detailed recommendation define the referenced "validated quality standards" of the German S3-Guideline Prostate Cancer and describe in detail the topic 1. anamnestic datas, 2. termination of examinations and preparation of examinations, 3. examination protocol and 4. MRI-(in-bore)-biopsy. KEY POINTS:: · The recommendations for preparation and scanning protocol of the multiparametric MRI of the Prostate were revised and updated in a consensus process and harmonized with the managing board of German Roentgen Society (DRG) and Professional Asssociation of the German Radiologist (BDR).. · Detailed recommendations are given for topic 1. anamnestic datas, 2. termination and preparation of examinations, 3. examination protocoll and 4. MRI-(in-bore)-biopsy.. · These recommendations define the referenced "validated quality standards" of the German S3-Guideline Prostate Cancer.. CITATION FORMAT: · Franiel T, Asbach P, Beyersdorff D et al. mpMRI of the Prostate (MR-Prostatography): Updated Recommendations of the DRG and BDR on Patient Preparation and Examination Protocol. Fortschr Röntgenstr 2021; 193: 763 - 776.
AB - The Working Group Uroradiology and Urogenital Diagnosis of the German Roentgen Society (DRG) revised and updated the recommendations for preparation and scanning protocol of the multiparametric MRI of the Prostate in a consensus process and harmonized it with the managing board of German Roentgen Society and Professional Association of the German Radiologist (BDR e. V.). These detailed recommendation define the referenced "validated quality standards" of the German S3-Guideline Prostate Cancer and describe in detail the topic 1. anamnestic datas, 2. termination of examinations and preparation of examinations, 3. examination protocol and 4. MRI-(in-bore)-biopsy. KEY POINTS:: · The recommendations for preparation and scanning protocol of the multiparametric MRI of the Prostate were revised and updated in a consensus process and harmonized with the managing board of German Roentgen Society (DRG) and Professional Asssociation of the German Radiologist (BDR).. · Detailed recommendations are given for topic 1. anamnestic datas, 2. termination and preparation of examinations, 3. examination protocoll and 4. MRI-(in-bore)-biopsy.. · These recommendations define the referenced "validated quality standards" of the German S3-Guideline Prostate Cancer.. CITATION FORMAT: · Franiel T, Asbach P, Beyersdorff D et al. mpMRI of the Prostate (MR-Prostatography): Updated Recommendations of the DRG and BDR on Patient Preparation and Examination Protocol. Fortschr Röntgenstr 2021; 193: 763 - 776.
KW - Biopsy, Needle
KW - Humans
KW - Male
KW - Multiparametric Magnetic Resonance Imaging/methods
KW - Prostate/diagnostic imaging
KW - Prostate-Specific Antigen/blood
KW - Prostatic Neoplasms/diagnostic imaging
KW - Risk Factors
KW - Societies, Medical
U2 - 10.1055/a-1406-8477
DO - 10.1055/a-1406-8477
M3 - SCORING: Journal article
C2 - 33735931
VL - 193
SP - 763
EP - 777
JO - ROFO-FORTSCHR RONTG
JF - ROFO-FORTSCHR RONTG
SN - 1438-9029
IS - 7
ER -