Mixed high energy photon and electron radiation fields for calibrating radiation protection dosemeters.

Standard

Mixed high energy photon and electron radiation fields for calibrating radiation protection dosemeters. / Büermann, L; Gargioni, Elisabetta; Kramer, H M.

in: RADIAT PROT DOSIM, Jahrgang 96, Nr. 1-3, 1-3, 2001, S. 213-218.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{877456297d364895b3c8ee57352c9c57,
title = "Mixed high energy photon and electron radiation fields for calibrating radiation protection dosemeters.",
abstract = "According to ISO 4037-3, calibrations of radiation protection dosemeters with photon radiation of energies above 3 MeV are performed under conditions of charged particle equilibrium. No information is provided concerning how to determine the response of dosemeters to radiation fields in the more general case when these conditions are not fulfilled. This paper deals with the production of mixed high energy photon and electron fields characterised by a lack or an excess of charged particles relative to conditions of equilibrium and describes a new procedure for the dosimetry in such fields. Through variation of the charged particle fluence fraction with respect to a nearly constant photon fluence, Hp(10) and H'(10) values varied by up to a factor of 1.74. The above mentioned basic study was utilised in the recent IAEA intercomparison (Co-ordinated Research Project 1996-1998) and EURADOS 'trial performance test' (1996-1998) for individual monitoring of photon radiation in testing response characteristics of individual dosemeters in non-charged particle equilibrium conditions.",
author = "L B{\"u}ermann and Elisabetta Gargioni and Kramer, {H M}",
year = "2001",
language = "Deutsch",
volume = "96",
pages = "213--218",
journal = "RADIAT PROT DOSIM",
issn = "0144-8420",
publisher = "Oxford University Press",
number = "1-3",

}

RIS

TY - JOUR

T1 - Mixed high energy photon and electron radiation fields for calibrating radiation protection dosemeters.

AU - Büermann, L

AU - Gargioni, Elisabetta

AU - Kramer, H M

PY - 2001

Y1 - 2001

N2 - According to ISO 4037-3, calibrations of radiation protection dosemeters with photon radiation of energies above 3 MeV are performed under conditions of charged particle equilibrium. No information is provided concerning how to determine the response of dosemeters to radiation fields in the more general case when these conditions are not fulfilled. This paper deals with the production of mixed high energy photon and electron fields characterised by a lack or an excess of charged particles relative to conditions of equilibrium and describes a new procedure for the dosimetry in such fields. Through variation of the charged particle fluence fraction with respect to a nearly constant photon fluence, Hp(10) and H'(10) values varied by up to a factor of 1.74. The above mentioned basic study was utilised in the recent IAEA intercomparison (Co-ordinated Research Project 1996-1998) and EURADOS 'trial performance test' (1996-1998) for individual monitoring of photon radiation in testing response characteristics of individual dosemeters in non-charged particle equilibrium conditions.

AB - According to ISO 4037-3, calibrations of radiation protection dosemeters with photon radiation of energies above 3 MeV are performed under conditions of charged particle equilibrium. No information is provided concerning how to determine the response of dosemeters to radiation fields in the more general case when these conditions are not fulfilled. This paper deals with the production of mixed high energy photon and electron fields characterised by a lack or an excess of charged particles relative to conditions of equilibrium and describes a new procedure for the dosimetry in such fields. Through variation of the charged particle fluence fraction with respect to a nearly constant photon fluence, Hp(10) and H'(10) values varied by up to a factor of 1.74. The above mentioned basic study was utilised in the recent IAEA intercomparison (Co-ordinated Research Project 1996-1998) and EURADOS 'trial performance test' (1996-1998) for individual monitoring of photon radiation in testing response characteristics of individual dosemeters in non-charged particle equilibrium conditions.

M3 - SCORING: Zeitschriftenaufsatz

VL - 96

SP - 213

EP - 218

JO - RADIAT PROT DOSIM

JF - RADIAT PROT DOSIM

SN - 0144-8420

IS - 1-3

M1 - 1-3

ER -