MALDI-TOF MS in lipidomics.

Standard

MALDI-TOF MS in lipidomics. / Schiller, Jurgen; Suss, Rosmarie; Fuchs, Beate; Müller, Matthias; Zschornig, Olaf; Arnold, Klaus.

in: FRONT BIOSCI-LANDMRK, Jahrgang 12, 2007, S. 2568-2579.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

Schiller, J, Suss, R, Fuchs, B, Müller, M, Zschornig, O & Arnold, K 2007, 'MALDI-TOF MS in lipidomics.', FRONT BIOSCI-LANDMRK, Jg. 12, S. 2568-2579. <http://www.ncbi.nlm.nih.gov/pubmed/17127263?dopt=Citation>

APA

Schiller, J., Suss, R., Fuchs, B., Müller, M., Zschornig, O., & Arnold, K. (2007). MALDI-TOF MS in lipidomics. FRONT BIOSCI-LANDMRK, 12, 2568-2579. http://www.ncbi.nlm.nih.gov/pubmed/17127263?dopt=Citation

Vancouver

Schiller J, Suss R, Fuchs B, Müller M, Zschornig O, Arnold K. MALDI-TOF MS in lipidomics. FRONT BIOSCI-LANDMRK. 2007;12:2568-2579.

Bibtex

@article{aae4c0db74c745e786347bf2f20759c0,
title = "MALDI-TOF MS in lipidomics.",
abstract = "So far, matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) seemed to be nearly a synonym for protein analysis. However, there is growing evidence that this technique is also an useful tool in lipid analysis and lipidomics because of its fast, simple and convenient performance allowing to record mass spectra of cells, crude tissue or body fluid extracts or even intact tissue slices in a few minutes. On the negative side, however, the reproducibility of MALDI-TOF mass spectra depends significantly on the homogeneity of the co-crystals between matrix and analyte and different lipid classes are detected with different sensitivities. This is especially important because lipids with quaternary ammonia groups (e.g., GPCho) may prevent the detection of other lipid classes (e.g., GPEtn). This review starts with a short overview on traditional methods of lipid analysis with the focus on mass spectrometric methods and compares MALDI-TOF MS with other important ionization techniques. Afterwards, some landmarks in the development of MALDI-TOF MS will be introduced and some important examples in the field of tissue and body fluid lipid analysis will be discussed. This review ends with a short outlook and summary focusing on the advantages and drawbacks of MALDI-TOF MS in lipidomics.",
author = "Jurgen Schiller and Rosmarie Suss and Beate Fuchs and Matthias M{\"u}ller and Olaf Zschornig and Klaus Arnold",
year = "2007",
language = "Deutsch",
volume = "12",
pages = "2568--2579",
journal = "FRONT BIOSCI-LANDMRK",
issn = "2768-6701",
publisher = "Frontiers in Bioscience",

}

RIS

TY - JOUR

T1 - MALDI-TOF MS in lipidomics.

AU - Schiller, Jurgen

AU - Suss, Rosmarie

AU - Fuchs, Beate

AU - Müller, Matthias

AU - Zschornig, Olaf

AU - Arnold, Klaus

PY - 2007

Y1 - 2007

N2 - So far, matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) seemed to be nearly a synonym for protein analysis. However, there is growing evidence that this technique is also an useful tool in lipid analysis and lipidomics because of its fast, simple and convenient performance allowing to record mass spectra of cells, crude tissue or body fluid extracts or even intact tissue slices in a few minutes. On the negative side, however, the reproducibility of MALDI-TOF mass spectra depends significantly on the homogeneity of the co-crystals between matrix and analyte and different lipid classes are detected with different sensitivities. This is especially important because lipids with quaternary ammonia groups (e.g., GPCho) may prevent the detection of other lipid classes (e.g., GPEtn). This review starts with a short overview on traditional methods of lipid analysis with the focus on mass spectrometric methods and compares MALDI-TOF MS with other important ionization techniques. Afterwards, some landmarks in the development of MALDI-TOF MS will be introduced and some important examples in the field of tissue and body fluid lipid analysis will be discussed. This review ends with a short outlook and summary focusing on the advantages and drawbacks of MALDI-TOF MS in lipidomics.

AB - So far, matrix-assisted laser desorption and ionization time-of-flight mass spectrometry (MALDI-TOF MS) seemed to be nearly a synonym for protein analysis. However, there is growing evidence that this technique is also an useful tool in lipid analysis and lipidomics because of its fast, simple and convenient performance allowing to record mass spectra of cells, crude tissue or body fluid extracts or even intact tissue slices in a few minutes. On the negative side, however, the reproducibility of MALDI-TOF mass spectra depends significantly on the homogeneity of the co-crystals between matrix and analyte and different lipid classes are detected with different sensitivities. This is especially important because lipids with quaternary ammonia groups (e.g., GPCho) may prevent the detection of other lipid classes (e.g., GPEtn). This review starts with a short overview on traditional methods of lipid analysis with the focus on mass spectrometric methods and compares MALDI-TOF MS with other important ionization techniques. Afterwards, some landmarks in the development of MALDI-TOF MS will be introduced and some important examples in the field of tissue and body fluid lipid analysis will be discussed. This review ends with a short outlook and summary focusing on the advantages and drawbacks of MALDI-TOF MS in lipidomics.

M3 - SCORING: Zeitschriftenaufsatz

VL - 12

SP - 2568

EP - 2579

JO - FRONT BIOSCI-LANDMRK

JF - FRONT BIOSCI-LANDMRK

SN - 2768-6701

ER -