Major influence of oxygen supply on 13CO2:12CO2 ratio measurement by nondispersive isotope-selective infrared spectroscopy.

Standard

Major influence of oxygen supply on 13CO2:12CO2 ratio measurement by nondispersive isotope-selective infrared spectroscopy. / Riecke, Björn; Neuhaus, Peter; Stockmann, Martin.

in: HELICOBACTER, Jahrgang 10, Nr. 6, 6, 2005, S. 620-622.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{ce2799c4cbfd4b8c919ab8205d4e4c2f,
title = "Major influence of oxygen supply on 13CO2:12CO2 ratio measurement by nondispersive isotope-selective infrared spectroscopy.",
abstract = "BACKGROUND: The nondispersive isotope-selective infrared spectroscopy (NDIRS) is a valid method for the measurement of the 13CO2:12CO2 ratio in breath samples. Methodical influences have to be considered to obtain valid results. AIM: To evaluate the effect of oxygen supply to patients on the measurement of 13C:12C ratio in breath samples by NDIRS. METHODS: Breath samples of 26 healthy volunteers were taken before, immediately after, and 5 minutes after inhalation of 100% oxygen via a continuous positive air pressure (CPAP) mask. Analysis of breath samples was performed by NDIRS. RESULTS: Delta per thousand before oxygen inhalation was -25.8 +/- 0.2. Immediately after 5 minutes of 100% oxygen inhalation, delta per thousand increased to -14.8 +/- 0.5 (delta over baseline [DOB] 11.0 +/- 0.4) and after additional 5 minutes of room air inhalation, delta per thousand normalized to -25.6 +/- 0.2 (DOB 0.2 +/- 0.1). CONCLUSIONS: Oxygen supply to patients and, therefore, changes in gas composition in breath samples clearly influence 13CO2 measurement by NDIRS. This has to be taken into account in the clinical setting. Thus, oxygen supply during measurement of exhaled 13CO2 by NDIRS has to be avoided or maintained at a strictly constant level.",
author = "Bj{\"o}rn Riecke and Peter Neuhaus and Martin Stockmann",
year = "2005",
language = "Deutsch",
volume = "10",
pages = "620--622",
journal = "HELICOBACTER",
issn = "1083-4389",
publisher = "Wiley-Blackwell",
number = "6",

}

RIS

TY - JOUR

T1 - Major influence of oxygen supply on 13CO2:12CO2 ratio measurement by nondispersive isotope-selective infrared spectroscopy.

AU - Riecke, Björn

AU - Neuhaus, Peter

AU - Stockmann, Martin

PY - 2005

Y1 - 2005

N2 - BACKGROUND: The nondispersive isotope-selective infrared spectroscopy (NDIRS) is a valid method for the measurement of the 13CO2:12CO2 ratio in breath samples. Methodical influences have to be considered to obtain valid results. AIM: To evaluate the effect of oxygen supply to patients on the measurement of 13C:12C ratio in breath samples by NDIRS. METHODS: Breath samples of 26 healthy volunteers were taken before, immediately after, and 5 minutes after inhalation of 100% oxygen via a continuous positive air pressure (CPAP) mask. Analysis of breath samples was performed by NDIRS. RESULTS: Delta per thousand before oxygen inhalation was -25.8 +/- 0.2. Immediately after 5 minutes of 100% oxygen inhalation, delta per thousand increased to -14.8 +/- 0.5 (delta over baseline [DOB] 11.0 +/- 0.4) and after additional 5 minutes of room air inhalation, delta per thousand normalized to -25.6 +/- 0.2 (DOB 0.2 +/- 0.1). CONCLUSIONS: Oxygen supply to patients and, therefore, changes in gas composition in breath samples clearly influence 13CO2 measurement by NDIRS. This has to be taken into account in the clinical setting. Thus, oxygen supply during measurement of exhaled 13CO2 by NDIRS has to be avoided or maintained at a strictly constant level.

AB - BACKGROUND: The nondispersive isotope-selective infrared spectroscopy (NDIRS) is a valid method for the measurement of the 13CO2:12CO2 ratio in breath samples. Methodical influences have to be considered to obtain valid results. AIM: To evaluate the effect of oxygen supply to patients on the measurement of 13C:12C ratio in breath samples by NDIRS. METHODS: Breath samples of 26 healthy volunteers were taken before, immediately after, and 5 minutes after inhalation of 100% oxygen via a continuous positive air pressure (CPAP) mask. Analysis of breath samples was performed by NDIRS. RESULTS: Delta per thousand before oxygen inhalation was -25.8 +/- 0.2. Immediately after 5 minutes of 100% oxygen inhalation, delta per thousand increased to -14.8 +/- 0.5 (delta over baseline [DOB] 11.0 +/- 0.4) and after additional 5 minutes of room air inhalation, delta per thousand normalized to -25.6 +/- 0.2 (DOB 0.2 +/- 0.1). CONCLUSIONS: Oxygen supply to patients and, therefore, changes in gas composition in breath samples clearly influence 13CO2 measurement by NDIRS. This has to be taken into account in the clinical setting. Thus, oxygen supply during measurement of exhaled 13CO2 by NDIRS has to be avoided or maintained at a strictly constant level.

M3 - SCORING: Zeitschriftenaufsatz

VL - 10

SP - 620

EP - 622

JO - HELICOBACTER

JF - HELICOBACTER

SN - 1083-4389

IS - 6

M1 - 6

ER -