Magnetresonanz-Bildgebung von einzelnen SPIO-markierten mesenchymalen Stammzellen bei 3 Tesla
Standard
Magnetresonanz-Bildgebung von einzelnen SPIO-markierten mesenchymalen Stammzellen bei 3 Tesla. / Peldschus, Kersten; Kaul, Michael; Lange, Claudia; Nolte-Ernsting, C; Adam, Gerhard; Ittrich, Harald.
in: ROFO-FORTSCHR RONTG, Jahrgang 179, Nr. 5, 01.05.2007, S. 473-479.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Magnetresonanz-Bildgebung von einzelnen SPIO-markierten mesenchymalen Stammzellen bei 3 Tesla
AU - Peldschus, Kersten
AU - Kaul, Michael
AU - Lange, Claudia
AU - Nolte-Ernsting, C
AU - Adam, Gerhard
AU - Ittrich, Harald
PY - 2007/5/1
Y1 - 2007/5/1
N2 - PURPOSE: To assess the detectability of single magnetically labeled mesenchymal stem cells (MSC) in-vitro on a clinical 3T MR scanner using a small animal volume coil. MATERIALS AND METHODS: GFP-transfected MSC were magnetically labeled with superparamagnetic iron oxide particles (SPIO) while applying different dosages of iron (56 vs. 560 microg Fe/ml). The cellular iron content was determined with atomic absorption spectrometry (AAS). Single labeled MSC were displayed in a culture flask using MR imaging and microscopy. Special cell phantoms were designed to examine the detection of labeled MSC with MR imaging in a spatial model. A T2*-weighted 3D gradient echo sequence with isotropic spatial resolution of 150 to 500 microm (3) was used for image acquisition. The detection of labeled MSC in the cell phantoms was quantitatively evaluated using an automated image analysis. Statistical analysis was performed with a significance level of p <0.05. RESULTS: The labeling of MSC yielded a mean cellular iron content of 1.5 +/- 0.17 pg Fe/cell (56 microg Fe/ml) and 8.3 +/- 1.85 pg Fe/cell (560 microg Fe/ml). Examination of the culture flasks showed single magnetically labeled MSC centered in much larger MR signal voids. The detection and quantification of single MSC in cell phantoms were feasible for spatial resolutions of 150 microm and 200 microm. Cells with a lower SPIO content (1.5 +/- 0.17 pg Fe/cell) were detected in 14.2 +/- 4.2 % (150 microm) and 7.7 +/- 3.8 % (200 microm). MSC with a higher cellular SPIO content (8.3 +/- 1.85 pg Fe/cell) revealed significantly higher occurrences at both spatial resolutions with 81.4 +/- 5.8 % (150 microm) and 59.9 +/- 12.4 % (200 microm), respectively. Regarding the spatial resolution (150 vs. 200 microm), significantly different detection rates were determined only for MSC with the higher SPIO content (8.3 +/- 1.85 pg Fe/cell). CONCLUSION: Detection of single magnetically labeled MSC is feasible on a clinical 3T MR scanner with a small animal volume coil at isotropic spatial resolutions of 150 microm and 200 microm. The number of detected cells is influenced by the cellular iron content and the spatial resolution.
AB - PURPOSE: To assess the detectability of single magnetically labeled mesenchymal stem cells (MSC) in-vitro on a clinical 3T MR scanner using a small animal volume coil. MATERIALS AND METHODS: GFP-transfected MSC were magnetically labeled with superparamagnetic iron oxide particles (SPIO) while applying different dosages of iron (56 vs. 560 microg Fe/ml). The cellular iron content was determined with atomic absorption spectrometry (AAS). Single labeled MSC were displayed in a culture flask using MR imaging and microscopy. Special cell phantoms were designed to examine the detection of labeled MSC with MR imaging in a spatial model. A T2*-weighted 3D gradient echo sequence with isotropic spatial resolution of 150 to 500 microm (3) was used for image acquisition. The detection of labeled MSC in the cell phantoms was quantitatively evaluated using an automated image analysis. Statistical analysis was performed with a significance level of p <0.05. RESULTS: The labeling of MSC yielded a mean cellular iron content of 1.5 +/- 0.17 pg Fe/cell (56 microg Fe/ml) and 8.3 +/- 1.85 pg Fe/cell (560 microg Fe/ml). Examination of the culture flasks showed single magnetically labeled MSC centered in much larger MR signal voids. The detection and quantification of single MSC in cell phantoms were feasible for spatial resolutions of 150 microm and 200 microm. Cells with a lower SPIO content (1.5 +/- 0.17 pg Fe/cell) were detected in 14.2 +/- 4.2 % (150 microm) and 7.7 +/- 3.8 % (200 microm). MSC with a higher cellular SPIO content (8.3 +/- 1.85 pg Fe/cell) revealed significantly higher occurrences at both spatial resolutions with 81.4 +/- 5.8 % (150 microm) and 59.9 +/- 12.4 % (200 microm), respectively. Regarding the spatial resolution (150 vs. 200 microm), significantly different detection rates were determined only for MSC with the higher SPIO content (8.3 +/- 1.85 pg Fe/cell). CONCLUSION: Detection of single magnetically labeled MSC is feasible on a clinical 3T MR scanner with a small animal volume coil at isotropic spatial resolutions of 150 microm and 200 microm. The number of detected cells is influenced by the cellular iron content and the spatial resolution.
KW - Animals
KW - Contrast Media
KW - Feasibility Studies
KW - Ferric Compounds
KW - Ferrosoferric Oxide
KW - Image Enhancement
KW - Image Processing, Computer-Assisted
KW - Magnetic Resonance Imaging
KW - Mesenchymal Stromal Cells
KW - Phantoms, Imaging
KW - Rats
KW - Rats, Sprague-Dawley
KW - Spectrophotometry, Atomic
U2 - 10.1055/s-2006-927370
DO - 10.1055/s-2006-927370
M3 - SCORING: Zeitschriftenaufsatz
C2 - 17436181
VL - 179
SP - 473
EP - 479
JO - ROFO-FORTSCHR RONTG
JF - ROFO-FORTSCHR RONTG
SN - 1438-9029
IS - 5
ER -