Laser in situ keratomileusis for astigmatism ≤ 0.75 diopter combined with low myopia: a retrospective data analysis

Standard

Laser in situ keratomileusis for astigmatism ≤ 0.75 diopter combined with low myopia: a retrospective data analysis. / Katz, Toam; Frings, Andreas; Linke, Stephan J; Richard, Gisbert; Druchkiv, Vasyl; Steinberg, Johannes.

in: BMC OPHTHALMOL, Jahrgang 14, 2014, S. 1.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{582ab0b48ab0471b8b00c71944d2c87e,
title = "Laser in situ keratomileusis for astigmatism ≤ 0.75 diopter combined with low myopia: a retrospective data analysis",
abstract = "BACKGROUND: This study examined the refractive and visual outcome of wavefront-optimized laser in situ keratomileusis (LASIK) in eyes with low myopia and compound myopic astigmatism ≤ 0.75 diopter (D).METHODS: 153 eyes from 153 consecutive myopic patients (74 male, 79 female; mean age at surgery 40.4 ± 10.4 years) who had a preoperative refractive cylinder ≤ 0.75 D and a manifest sphere between -0.25 D and -2.75 D, and who had completed 4-month follow-up. Three subgroups defined by the magnitude of preoperative manifest refractive cylinder (0.25, 0.50, and 0.75 D) were formed. Manifest refraction, uncorrected and corrected visual acuity were assessed pre- and postoperatively. The astigmatic changes achieved were determined using the Alpins vector analysis.RESULTS: After 4 months (120.0 ± 27.6 days) of follow-up, a mean uncorrected distant visual acuity of 0.07 ± 0.11 logMAR and a mean manifest refraction spherical equivalent of -0.06 ± 0.56 D were found. There was no statistically significant difference in efficacy and safety between the preoperative cylinder groups. Astigmatic overcorrection for preoperative cylinder of ≤ 0.50 D was suggested by the correction index, the magnitude of error, the index of success, and the flattening index.CONCLUSIONS: Low myopic eyes with a preoperative cylinder of ≤ 0.50 D were significantly overcorrected with regard to cylinder correction when combined with low myopic LASIK. Accordingly, we are cautious in recommending full astigmatic correction for eyes with low myopia and manifest cylinder of ≤ 0.50 D.",
author = "Toam Katz and Andreas Frings and Linke, {Stephan J} and Gisbert Richard and Vasyl Druchkiv and Johannes Steinberg",
year = "2014",
doi = "10.1186/1471-2415-14-1",
language = "English",
volume = "14",
pages = "1",
journal = "BMC OPHTHALMOL",
issn = "1471-2415",
publisher = "BioMed Central Ltd.",

}

RIS

TY - JOUR

T1 - Laser in situ keratomileusis for astigmatism ≤ 0.75 diopter combined with low myopia: a retrospective data analysis

AU - Katz, Toam

AU - Frings, Andreas

AU - Linke, Stephan J

AU - Richard, Gisbert

AU - Druchkiv, Vasyl

AU - Steinberg, Johannes

PY - 2014

Y1 - 2014

N2 - BACKGROUND: This study examined the refractive and visual outcome of wavefront-optimized laser in situ keratomileusis (LASIK) in eyes with low myopia and compound myopic astigmatism ≤ 0.75 diopter (D).METHODS: 153 eyes from 153 consecutive myopic patients (74 male, 79 female; mean age at surgery 40.4 ± 10.4 years) who had a preoperative refractive cylinder ≤ 0.75 D and a manifest sphere between -0.25 D and -2.75 D, and who had completed 4-month follow-up. Three subgroups defined by the magnitude of preoperative manifest refractive cylinder (0.25, 0.50, and 0.75 D) were formed. Manifest refraction, uncorrected and corrected visual acuity were assessed pre- and postoperatively. The astigmatic changes achieved were determined using the Alpins vector analysis.RESULTS: After 4 months (120.0 ± 27.6 days) of follow-up, a mean uncorrected distant visual acuity of 0.07 ± 0.11 logMAR and a mean manifest refraction spherical equivalent of -0.06 ± 0.56 D were found. There was no statistically significant difference in efficacy and safety between the preoperative cylinder groups. Astigmatic overcorrection for preoperative cylinder of ≤ 0.50 D was suggested by the correction index, the magnitude of error, the index of success, and the flattening index.CONCLUSIONS: Low myopic eyes with a preoperative cylinder of ≤ 0.50 D were significantly overcorrected with regard to cylinder correction when combined with low myopic LASIK. Accordingly, we are cautious in recommending full astigmatic correction for eyes with low myopia and manifest cylinder of ≤ 0.50 D.

AB - BACKGROUND: This study examined the refractive and visual outcome of wavefront-optimized laser in situ keratomileusis (LASIK) in eyes with low myopia and compound myopic astigmatism ≤ 0.75 diopter (D).METHODS: 153 eyes from 153 consecutive myopic patients (74 male, 79 female; mean age at surgery 40.4 ± 10.4 years) who had a preoperative refractive cylinder ≤ 0.75 D and a manifest sphere between -0.25 D and -2.75 D, and who had completed 4-month follow-up. Three subgroups defined by the magnitude of preoperative manifest refractive cylinder (0.25, 0.50, and 0.75 D) were formed. Manifest refraction, uncorrected and corrected visual acuity were assessed pre- and postoperatively. The astigmatic changes achieved were determined using the Alpins vector analysis.RESULTS: After 4 months (120.0 ± 27.6 days) of follow-up, a mean uncorrected distant visual acuity of 0.07 ± 0.11 logMAR and a mean manifest refraction spherical equivalent of -0.06 ± 0.56 D were found. There was no statistically significant difference in efficacy and safety between the preoperative cylinder groups. Astigmatic overcorrection for preoperative cylinder of ≤ 0.50 D was suggested by the correction index, the magnitude of error, the index of success, and the flattening index.CONCLUSIONS: Low myopic eyes with a preoperative cylinder of ≤ 0.50 D were significantly overcorrected with regard to cylinder correction when combined with low myopic LASIK. Accordingly, we are cautious in recommending full astigmatic correction for eyes with low myopia and manifest cylinder of ≤ 0.50 D.

U2 - 10.1186/1471-2415-14-1

DO - 10.1186/1471-2415-14-1

M3 - SCORING: Journal article

C2 - 24393469

VL - 14

SP - 1

JO - BMC OPHTHALMOL

JF - BMC OPHTHALMOL

SN - 1471-2415