Abstract

During the last 30 years intraoperative electrophysiological monitoring (IOEM) has gained increasing importance in monitoring the function of neuronal structures and the intraoperative detection of impending new neurological deficits. The use of IOEM could reduce the incidence of postoperative neurological deficits after various surgical procedures. Motor evoked potentials (MEP) seem to be superior to other methods for many indications regarding monitoring of the central nervous system. During the application of IOEM general anesthesia should be provided by total intravenous anesthesia with propofol with an emphasis on a continuous high opioid dosage. When intraoperative MEP or electromyography guidance is planned, muscle relaxation must be either completely omitted or maintained in a titrated dose range in a steady state. The IOEM can be performed by surgeons, neurologists and neurophysiologists or increasingly more by anesthesiologists. However, to guarantee a safe application and interpretation, sufficient knowledge of the effects of the surgical procedure and pharmacological and physiological influences on the neurophysiological findings are indispensable.

Bibliografische Daten

Titel in ÜbersetzungIntraoperative electrophysiological monitoring with evoked potentials
OriginalspracheDeutsch
ISSN0003-2417
DOIs
StatusVeröffentlicht - 04.2012
PubMed 22526743