Influence of VECTOR2 Polish Fluid on Implant Surface Roughnesses

Standard

Influence of VECTOR2 Polish Fluid on Implant Surface Roughnesses. / Schmage, Petra; Sollich, Meike; Nergiz, Ibrahim; Platzer, Ursula.

in: INT DENT J, Jahrgang 65, Nr. S2; 152, 212, 23.09.2015.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungKonferenz-Abstract in FachzeitschriftForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{ea83dd3827d74180964d4015bfaed301,
title = "Influence of VECTOR2 Polish Fluid on Implant Surface Roughnesses",
abstract = "Aim and purpose: This study aimed to evaluate surface roughnessalterations of 2 implant surface structures after biofilm removingusing an ultrasonic driven cleaning devise with different tips andwith or without additional polishing fluid (PF).Materials and method: Respectively 40 titanium specimen of 2common surfaces (smooth SM, Sa = 0.2  0.02 lm; grit-blastedGB, Sa = 0.86  0.21 lm), were randomly selected into 8 groupsand cultivated with Streptococcus mutans. Then ultrasonic clean-ing was performed using 4 implant cleaning tips with or withoutPF within 1 min: ceramic (C), long (L) and short (S) carbon fibersor natural fibers (N). Average surface roughnesses Sa were assessedlaser profilometrically at 5 areas of each specimen and comparedwith the results before treatment (B). Statistical analysis was car-ried out (one-way ANOVA, Bonferroni/Dunn correction, t-test,a = 0.05).Results: The cleaning efficiency allowed the analysis. Sa of SMwas not significantly altered by the treatment regardless of PF(without PF: C 0.18  0.02 lm – L 0.21  0.03 lm; with PF: N0.25  0.06 lm – L 0.31  0.12 lm) (p > 0.05). Sa of GB withPF varied not significantly (C 0.95  0.21 lm–S 1.05  0.23 lm)compared to B (p > 0.05). Cleaning reduced Sa of GB significantlyfor C (0.65  0.08 lm) and N 0.67  0.04 lm) without PF(p < 0.05). For all tips Sa of GB differed significantly comparingwith and without PF (p < 0.01).Summary and conclusions: Implant cleaning tips proved reduction,but no alteration without PF on both surfaces. PF increased Sadepending on the surface structure. C tips without PF showedmore abrasion and smoothening, while all fiber tips with PF pro-vided surface removal and roughening. The tested ultrasonic sys-tem can be recommended for implant cleaning regarding surface alterations.",
author = "Petra Schmage and Meike Sollich and Ibrahim Nergiz and Ursula Platzer",
year = "2015",
month = sep,
day = "23",
language = "English",
volume = "65",
journal = "INT DENT J",
issn = "0020-6539",
publisher = "Wiley-Blackwell",
number = "S2; 152",
note = "null ; Conference date: 22-09-2015 Through 25-09-2015",

}

RIS

TY - JOUR

T1 - Influence of VECTOR2 Polish Fluid on Implant Surface Roughnesses

AU - Schmage, Petra

AU - Sollich, Meike

AU - Nergiz, Ibrahim

AU - Platzer, Ursula

PY - 2015/9/23

Y1 - 2015/9/23

N2 - Aim and purpose: This study aimed to evaluate surface roughnessalterations of 2 implant surface structures after biofilm removingusing an ultrasonic driven cleaning devise with different tips andwith or without additional polishing fluid (PF).Materials and method: Respectively 40 titanium specimen of 2common surfaces (smooth SM, Sa = 0.2  0.02 lm; grit-blastedGB, Sa = 0.86  0.21 lm), were randomly selected into 8 groupsand cultivated with Streptococcus mutans. Then ultrasonic clean-ing was performed using 4 implant cleaning tips with or withoutPF within 1 min: ceramic (C), long (L) and short (S) carbon fibersor natural fibers (N). Average surface roughnesses Sa were assessedlaser profilometrically at 5 areas of each specimen and comparedwith the results before treatment (B). Statistical analysis was car-ried out (one-way ANOVA, Bonferroni/Dunn correction, t-test,a = 0.05).Results: The cleaning efficiency allowed the analysis. Sa of SMwas not significantly altered by the treatment regardless of PF(without PF: C 0.18  0.02 lm – L 0.21  0.03 lm; with PF: N0.25  0.06 lm – L 0.31  0.12 lm) (p > 0.05). Sa of GB withPF varied not significantly (C 0.95  0.21 lm–S 1.05  0.23 lm)compared to B (p > 0.05). Cleaning reduced Sa of GB significantlyfor C (0.65  0.08 lm) and N 0.67  0.04 lm) without PF(p < 0.05). For all tips Sa of GB differed significantly comparingwith and without PF (p < 0.01).Summary and conclusions: Implant cleaning tips proved reduction,but no alteration without PF on both surfaces. PF increased Sadepending on the surface structure. C tips without PF showedmore abrasion and smoothening, while all fiber tips with PF pro-vided surface removal and roughening. The tested ultrasonic sys-tem can be recommended for implant cleaning regarding surface alterations.

AB - Aim and purpose: This study aimed to evaluate surface roughnessalterations of 2 implant surface structures after biofilm removingusing an ultrasonic driven cleaning devise with different tips andwith or without additional polishing fluid (PF).Materials and method: Respectively 40 titanium specimen of 2common surfaces (smooth SM, Sa = 0.2  0.02 lm; grit-blastedGB, Sa = 0.86  0.21 lm), were randomly selected into 8 groupsand cultivated with Streptococcus mutans. Then ultrasonic clean-ing was performed using 4 implant cleaning tips with or withoutPF within 1 min: ceramic (C), long (L) and short (S) carbon fibersor natural fibers (N). Average surface roughnesses Sa were assessedlaser profilometrically at 5 areas of each specimen and comparedwith the results before treatment (B). Statistical analysis was car-ried out (one-way ANOVA, Bonferroni/Dunn correction, t-test,a = 0.05).Results: The cleaning efficiency allowed the analysis. Sa of SMwas not significantly altered by the treatment regardless of PF(without PF: C 0.18  0.02 lm – L 0.21  0.03 lm; with PF: N0.25  0.06 lm – L 0.31  0.12 lm) (p > 0.05). Sa of GB withPF varied not significantly (C 0.95  0.21 lm–S 1.05  0.23 lm)compared to B (p > 0.05). Cleaning reduced Sa of GB significantlyfor C (0.65  0.08 lm) and N 0.67  0.04 lm) without PF(p < 0.05). For all tips Sa of GB differed significantly comparingwith and without PF (p < 0.01).Summary and conclusions: Implant cleaning tips proved reduction,but no alteration without PF on both surfaces. PF increased Sadepending on the surface structure. C tips without PF showedmore abrasion and smoothening, while all fiber tips with PF pro-vided surface removal and roughening. The tested ultrasonic sys-tem can be recommended for implant cleaning regarding surface alterations.

UR - https://onlinelibrary.wiley.com/doi/epdf/10.1111/idj.12195

M3 - Conference abstract in journal

VL - 65

JO - INT DENT J

JF - INT DENT J

SN - 0020-6539

IS - S2; 152

M1 - 212

Y2 - 22 September 2015 through 25 September 2015

ER -