Influence of intrinsic noise generated by a thermotesting device on thermal sensory detection and thermal pain detection thresholds.
Standard
Influence of intrinsic noise generated by a thermotesting device on thermal sensory detection and thermal pain detection thresholds. / Pavlaković, G; Züchner, K; Zapf, A; Bachmann, C G; Graf, B M; Crozier, T A; Pavlaković, H.
in: MUSCLE NERVE, Jahrgang 40, Nr. 2, 08.2009, S. 257-263.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Influence of intrinsic noise generated by a thermotesting device on thermal sensory detection and thermal pain detection thresholds.
AU - Pavlaković, G
AU - Züchner, K
AU - Zapf, A
AU - Bachmann, C G
AU - Graf, B M
AU - Crozier, T A
AU - Pavlaković, H
PY - 2009/8
Y1 - 2009/8
N2 - Various factors can influence thermal perception threshold measurements and contribute significantly to unwanted variability of the tests. To minimize this variability, testing should be performed under strictly controlled conditions. Identifying the factors that increase the variability and eliminating their influence should increase reliability and reproducibility. Currently available thermotesting devices use a water-cooling system that generates a continuous noise of approximately 60 dB. In order to analyze whether this noise could influence the thermal threshold measurements we compared the thresholds obtained with a silent thermotesting device to those obtained with a commercially available device. The subjects were tested with one randomly chosen device on 1 day and with the other device 7 days later. At each session, heat, heat pain, cold, and cold pain thresholds were determined with three measurements. Bland-Altman analysis was used to assess agreement in measurements obtained with different devices and it was shown that the intersubject variability of the thresholds obtained with the two devices was comparable for all four thresholds tested. In contrast, the intrasubject variability of the thresholds for heat, heat pain, and cold pain detection was significantly lower with the silent device. Our results show that thermal sensory thresholds measured with the two devices are comparable. However, our data suggest that, for studies with repeated measurements on the same subjects, a silent thermotesting device may allow detection of smaller differences in the treatment effects and/or may permit the use of a smaller number of tested subjects. Muscle Nerve 40: 257-263, 2009.
AB - Various factors can influence thermal perception threshold measurements and contribute significantly to unwanted variability of the tests. To minimize this variability, testing should be performed under strictly controlled conditions. Identifying the factors that increase the variability and eliminating their influence should increase reliability and reproducibility. Currently available thermotesting devices use a water-cooling system that generates a continuous noise of approximately 60 dB. In order to analyze whether this noise could influence the thermal threshold measurements we compared the thresholds obtained with a silent thermotesting device to those obtained with a commercially available device. The subjects were tested with one randomly chosen device on 1 day and with the other device 7 days later. At each session, heat, heat pain, cold, and cold pain thresholds were determined with three measurements. Bland-Altman analysis was used to assess agreement in measurements obtained with different devices and it was shown that the intersubject variability of the thresholds obtained with the two devices was comparable for all four thresholds tested. In contrast, the intrasubject variability of the thresholds for heat, heat pain, and cold pain detection was significantly lower with the silent device. Our results show that thermal sensory thresholds measured with the two devices are comparable. However, our data suggest that, for studies with repeated measurements on the same subjects, a silent thermotesting device may allow detection of smaller differences in the treatment effects and/or may permit the use of a smaller number of tested subjects. Muscle Nerve 40: 257-263, 2009.
KW - Adult
KW - Female
KW - Humans
KW - Male
KW - Middle Aged
KW - Noise
KW - Pain
KW - Pain Measurement
KW - Physical Stimulation
KW - Psychophysics
KW - Reproducibility of Results
KW - Sensory Thresholds
KW - Temperature
KW - Thermosensing
KW - Journal Article
KW - Randomized Controlled Trial
KW - Research Support, Non-U.S. Gov't
U2 - 10.1002/mus.21270
DO - 10.1002/mus.21270
M3 - SCORING: Journal article
C2 - 19367649
VL - 40
SP - 257
EP - 263
JO - MUSCLE NERVE
JF - MUSCLE NERVE
SN - 0148-639X
IS - 2
ER -