Improved detectability of acute and subacute brainstem infarctions by combining standard axial and thin-sliced sagittal DWI

Standard

Improved detectability of acute and subacute brainstem infarctions by combining standard axial and thin-sliced sagittal DWI. / Schönfeld, Michael H; Ritzel, Robert M; Kemmling, Andre; Ernst, Marielle; Fiehler, Jens; Gellißen, Susanne.

in: PLOS ONE, Jahrgang 13, Nr. 7, 03.07.2018, S. e0200092.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{b7f566b3c86f4e5a91cc74cca19df561,
title = "Improved detectability of acute and subacute brainstem infarctions by combining standard axial and thin-sliced sagittal DWI",
abstract = "BACKGROUND AND PURPOSE: Most false negative findings in DWI of ischemic stroke are in patients with minor deficits clinically localized to the brainstem. Our goal was to evaluate the benefit of a thin-sliced sagittal DWI in addition to conventional axial DWI at 1.5T for the detection of brainstem infarctions.METHODS: Data of patients with symptoms consistent with acute and subacute brainstem infarction and an MRI examination including standard axial DWI and thin-sliced sagittal DWI were retrospectively analyzed. Patients with the later diagnosis of a TIA, an inflammation or a tumor of the brainstem were excluded from analysis. Diffusion restrictions were identified by two independent raters blinded for the final clinical diagnosis in three separate reading steps: First, only axial DWI, secondly only sagittal DWI, and lastly both DWIs together. Presence and size of DWI-lesions were documented for each plane. Differences between the observers were settled in consensus in a separate joint reading.RESULTS: Of 73 included patients, 46 patients were clinically diagnosed with brainstem infarction. Inter-observer agreement was excellent for the detection of brainstem lesions in axial and sagittal DWI (kappa = 0.94 and 0.97). In 28/46 patients (60.9%) lesions were detected in the axial plane alone, whereas in 6 more patients (73.9%) lesions were detected in the review of both sequences together. All lesions undetectable in the axial plane were smaller than 5 mm in cranio-caudal direction.CONCLUSIONS: Thin-sliced sagittal DWI in addition to axial DWI improves the detection rate of brainstem infarction with little additional expenditure of time.",
keywords = "Journal Article",
author = "Sch{\"o}nfeld, {Michael H} and Ritzel, {Robert M} and Andre Kemmling and Marielle Ernst and Jens Fiehler and Susanne Gelli{\ss}en",
year = "2018",
month = jul,
day = "3",
doi = "10.1371/journal.pone.0200092",
language = "English",
volume = "13",
pages = "e0200092",
journal = "PLOS ONE",
issn = "1932-6203",
publisher = "Public Library of Science",
number = "7",

}

RIS

TY - JOUR

T1 - Improved detectability of acute and subacute brainstem infarctions by combining standard axial and thin-sliced sagittal DWI

AU - Schönfeld, Michael H

AU - Ritzel, Robert M

AU - Kemmling, Andre

AU - Ernst, Marielle

AU - Fiehler, Jens

AU - Gellißen, Susanne

PY - 2018/7/3

Y1 - 2018/7/3

N2 - BACKGROUND AND PURPOSE: Most false negative findings in DWI of ischemic stroke are in patients with minor deficits clinically localized to the brainstem. Our goal was to evaluate the benefit of a thin-sliced sagittal DWI in addition to conventional axial DWI at 1.5T for the detection of brainstem infarctions.METHODS: Data of patients with symptoms consistent with acute and subacute brainstem infarction and an MRI examination including standard axial DWI and thin-sliced sagittal DWI were retrospectively analyzed. Patients with the later diagnosis of a TIA, an inflammation or a tumor of the brainstem were excluded from analysis. Diffusion restrictions were identified by two independent raters blinded for the final clinical diagnosis in three separate reading steps: First, only axial DWI, secondly only sagittal DWI, and lastly both DWIs together. Presence and size of DWI-lesions were documented for each plane. Differences between the observers were settled in consensus in a separate joint reading.RESULTS: Of 73 included patients, 46 patients were clinically diagnosed with brainstem infarction. Inter-observer agreement was excellent for the detection of brainstem lesions in axial and sagittal DWI (kappa = 0.94 and 0.97). In 28/46 patients (60.9%) lesions were detected in the axial plane alone, whereas in 6 more patients (73.9%) lesions were detected in the review of both sequences together. All lesions undetectable in the axial plane were smaller than 5 mm in cranio-caudal direction.CONCLUSIONS: Thin-sliced sagittal DWI in addition to axial DWI improves the detection rate of brainstem infarction with little additional expenditure of time.

AB - BACKGROUND AND PURPOSE: Most false negative findings in DWI of ischemic stroke are in patients with minor deficits clinically localized to the brainstem. Our goal was to evaluate the benefit of a thin-sliced sagittal DWI in addition to conventional axial DWI at 1.5T for the detection of brainstem infarctions.METHODS: Data of patients with symptoms consistent with acute and subacute brainstem infarction and an MRI examination including standard axial DWI and thin-sliced sagittal DWI were retrospectively analyzed. Patients with the later diagnosis of a TIA, an inflammation or a tumor of the brainstem were excluded from analysis. Diffusion restrictions were identified by two independent raters blinded for the final clinical diagnosis in three separate reading steps: First, only axial DWI, secondly only sagittal DWI, and lastly both DWIs together. Presence and size of DWI-lesions were documented for each plane. Differences between the observers were settled in consensus in a separate joint reading.RESULTS: Of 73 included patients, 46 patients were clinically diagnosed with brainstem infarction. Inter-observer agreement was excellent for the detection of brainstem lesions in axial and sagittal DWI (kappa = 0.94 and 0.97). In 28/46 patients (60.9%) lesions were detected in the axial plane alone, whereas in 6 more patients (73.9%) lesions were detected in the review of both sequences together. All lesions undetectable in the axial plane were smaller than 5 mm in cranio-caudal direction.CONCLUSIONS: Thin-sliced sagittal DWI in addition to axial DWI improves the detection rate of brainstem infarction with little additional expenditure of time.

KW - Journal Article

U2 - 10.1371/journal.pone.0200092

DO - 10.1371/journal.pone.0200092

M3 - SCORING: Journal article

C2 - 29969485

VL - 13

SP - e0200092

JO - PLOS ONE

JF - PLOS ONE

SN - 1932-6203

IS - 7

ER -