High-sensitivity troponin I and all-cause mortality in patients with stable COPD: An analysis of the COSYCONET study
Standard
High-sensitivity troponin I and all-cause mortality in patients with stable COPD: An analysis of the COSYCONET study. / Waschki, Benjamin; Alter, Peter; Zeller, Tanja; Magnussen, Christina; Neumann, Johannes T; Twerenbold, Raphael; Sinning, Christoph; Herr, Christian; Kahnert, Kathrin; Fähndrich, Sebastian; Blankenberg, Stefan; Rabe, Klaus F; Welte, Tobias; Jörres, Rudolf A; Vogelmeier, Claus F; Bals, Robert; Watz, Henrik; German COSYCONET Cohort.
in: EUR RESPIR J, Jahrgang 55, Nr. 2, 1901314, 02.2020.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - High-sensitivity troponin I and all-cause mortality in patients with stable COPD: An analysis of the COSYCONET study
AU - Waschki, Benjamin
AU - Alter, Peter
AU - Zeller, Tanja
AU - Magnussen, Christina
AU - Neumann, Johannes T
AU - Twerenbold, Raphael
AU - Sinning, Christoph
AU - Herr, Christian
AU - Kahnert, Kathrin
AU - Fähndrich, Sebastian
AU - Blankenberg, Stefan
AU - Rabe, Klaus F
AU - Welte, Tobias
AU - Jörres, Rudolf A
AU - Vogelmeier, Claus F
AU - Bals, Robert
AU - Watz, Henrik
AU - German COSYCONET Cohort
N1 - Copyright ©ERS 2020.
PY - 2020/2
Y1 - 2020/2
N2 - Chronic obstructive pulmonary disease (COPD) is a leading cause of death with a considerable part of the population dying from cardiovascular diseases. High-sensitivity troponin I (hs-TnI) might help to better identify COPD patients at high risk of mortality. We aimed to study the predictive value of hs-TnI for all-cause mortality beyond established COPD assessments, and after consideration of relevant cardiovascular risk factors and prevalent cardiovascular diseases, in a broad population with stable COPD.Circulating hs-TnI concentrations together with a wide range of respiratory and cardiovascular markers were evaluated in 2085 patients with stable COPD across all severity stages enrolled in the multicentre COSYCONET cohort study. The primary outcome was all-cause mortality over 3 years of follow-up.Hs-TnI was detectable in 2020 (96.9%) patients. The median hs-TnI concentration was 3.8 ng·L-1 (interquartile range 2.5-6.6 ng·L-1), with levels above the 99th percentile reference limit of 27 ng·L-1 observed in 1.8% of patients. In Cox regression analyses including adjustments for airflow limitation, dyspnoea grade, exercise capacity and history of severe exacerbations, as well as traditional cardiovascular risk factors, estimated glomerular filtration rate, ankle-brachial index, N-terminal pro-brain natriuretic peptides and prevalent cardiovascular diseases, hs-TnI was a significant predictor for all-cause mortality, both as a continuous variable (hazard ratio (HR) for log hs-TnI 1.28, 95% CI 1.01-1.62) and categorised according to the cut-off of 6 ng·L-1 (HR 1.63, 95% CI 1.10-2.42).In patients with stable COPD, hs-TnI is a strong predictor of all-cause mortality beyond established COPD mortality predictors, and independent of a broad range of cardiovascular risk factors and prevalent cardiovascular diseases. Hs-TnI concentrations well below the upper reference limit provide further prognostic value for all patients with COPD when added to established risk assessments.
AB - Chronic obstructive pulmonary disease (COPD) is a leading cause of death with a considerable part of the population dying from cardiovascular diseases. High-sensitivity troponin I (hs-TnI) might help to better identify COPD patients at high risk of mortality. We aimed to study the predictive value of hs-TnI for all-cause mortality beyond established COPD assessments, and after consideration of relevant cardiovascular risk factors and prevalent cardiovascular diseases, in a broad population with stable COPD.Circulating hs-TnI concentrations together with a wide range of respiratory and cardiovascular markers were evaluated in 2085 patients with stable COPD across all severity stages enrolled in the multicentre COSYCONET cohort study. The primary outcome was all-cause mortality over 3 years of follow-up.Hs-TnI was detectable in 2020 (96.9%) patients. The median hs-TnI concentration was 3.8 ng·L-1 (interquartile range 2.5-6.6 ng·L-1), with levels above the 99th percentile reference limit of 27 ng·L-1 observed in 1.8% of patients. In Cox regression analyses including adjustments for airflow limitation, dyspnoea grade, exercise capacity and history of severe exacerbations, as well as traditional cardiovascular risk factors, estimated glomerular filtration rate, ankle-brachial index, N-terminal pro-brain natriuretic peptides and prevalent cardiovascular diseases, hs-TnI was a significant predictor for all-cause mortality, both as a continuous variable (hazard ratio (HR) for log hs-TnI 1.28, 95% CI 1.01-1.62) and categorised according to the cut-off of 6 ng·L-1 (HR 1.63, 95% CI 1.10-2.42).In patients with stable COPD, hs-TnI is a strong predictor of all-cause mortality beyond established COPD mortality predictors, and independent of a broad range of cardiovascular risk factors and prevalent cardiovascular diseases. Hs-TnI concentrations well below the upper reference limit provide further prognostic value for all patients with COPD when added to established risk assessments.
KW - Biomarkers
KW - Cohort Studies
KW - Humans
KW - Prognosis
KW - Proportional Hazards Models
KW - Pulmonary Disease, Chronic Obstructive
KW - Risk Assessment
KW - Troponin I
KW - Troponin T
U2 - 10.1183/13993003.01314-2019
DO - 10.1183/13993003.01314-2019
M3 - SCORING: Journal article
C2 - 31831579
VL - 55
JO - EUR RESPIR J
JF - EUR RESPIR J
SN - 0903-1936
IS - 2
M1 - 1901314
ER -