Evaluation of methods for bolus arrival time determination using a four-dimensional MRA flow phantom.

Standard

Evaluation of methods for bolus arrival time determination using a four-dimensional MRA flow phantom. / Säring, Dennis; Forkert, Nils; Illies, Till; Fiehler, Jens; Handels, Heinz.

in: Stud Health Technol Inform, Jahrgang 160, Nr. 2, 2, 2010, S. 1263-1267.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

Säring, D, Forkert, N, Illies, T, Fiehler, J & Handels, H 2010, 'Evaluation of methods for bolus arrival time determination using a four-dimensional MRA flow phantom.', Stud Health Technol Inform, Jg. 160, Nr. 2, 2, S. 1263-1267. <http://www.ncbi.nlm.nih.gov/pubmed/20841887?dopt=Citation>

APA

Vancouver

Säring D, Forkert N, Illies T, Fiehler J, Handels H. Evaluation of methods for bolus arrival time determination using a four-dimensional MRA flow phantom. Stud Health Technol Inform. 2010;160(2):1263-1267. 2.

Bibtex

@article{8ca906b41b8b4217b2054e8b67b5f553,
title = "Evaluation of methods for bolus arrival time determination using a four-dimensional MRA flow phantom.",
abstract = "In this paper an evaluation of methods determining the bolus arrival time (BAT) using a four-dimensional flow phantom to simulate 4D MR angiography is presented. Spatiotemporal 4D MRA images were acquired for analyzing the hemodynamic characteristics of cerebral vessel anomalies. Model-independent and model-dependent methods for BAT extraction are published. Generally, for the evaluation no gold standard exists and datasets with known BAT values are required. Here, a 4D flow phantom is generated based on a synthetic 3D MRA dataset with BAT values defining the time point of blood inflow for each voxel. Then, voxel-by-voxel concentration-time curves based on the gamma-variate function were computed leading to a simulated 4D MRA dataset. Additionally, partial volume effects and Gaussian noise were integrated. The simulated 4D MRA was visually inspected and regarded as similar to clinical data. Finally, phantom datasets with different vessel diameter and signal-to-noise ratio are computed. Three state-of-the-art methods were used to extract BAT values. Computed and known values were compared. The results suggest that model-dependent approaches perform better than the model-independent method.",
author = "Dennis S{\"a}ring and Nils Forkert and Till Illies and Jens Fiehler and Heinz Handels",
year = "2010",
language = "Deutsch",
volume = "160",
pages = "1263--1267",
number = "2",

}

RIS

TY - JOUR

T1 - Evaluation of methods for bolus arrival time determination using a four-dimensional MRA flow phantom.

AU - Säring, Dennis

AU - Forkert, Nils

AU - Illies, Till

AU - Fiehler, Jens

AU - Handels, Heinz

PY - 2010

Y1 - 2010

N2 - In this paper an evaluation of methods determining the bolus arrival time (BAT) using a four-dimensional flow phantom to simulate 4D MR angiography is presented. Spatiotemporal 4D MRA images were acquired for analyzing the hemodynamic characteristics of cerebral vessel anomalies. Model-independent and model-dependent methods for BAT extraction are published. Generally, for the evaluation no gold standard exists and datasets with known BAT values are required. Here, a 4D flow phantom is generated based on a synthetic 3D MRA dataset with BAT values defining the time point of blood inflow for each voxel. Then, voxel-by-voxel concentration-time curves based on the gamma-variate function were computed leading to a simulated 4D MRA dataset. Additionally, partial volume effects and Gaussian noise were integrated. The simulated 4D MRA was visually inspected and regarded as similar to clinical data. Finally, phantom datasets with different vessel diameter and signal-to-noise ratio are computed. Three state-of-the-art methods were used to extract BAT values. Computed and known values were compared. The results suggest that model-dependent approaches perform better than the model-independent method.

AB - In this paper an evaluation of methods determining the bolus arrival time (BAT) using a four-dimensional flow phantom to simulate 4D MR angiography is presented. Spatiotemporal 4D MRA images were acquired for analyzing the hemodynamic characteristics of cerebral vessel anomalies. Model-independent and model-dependent methods for BAT extraction are published. Generally, for the evaluation no gold standard exists and datasets with known BAT values are required. Here, a 4D flow phantom is generated based on a synthetic 3D MRA dataset with BAT values defining the time point of blood inflow for each voxel. Then, voxel-by-voxel concentration-time curves based on the gamma-variate function were computed leading to a simulated 4D MRA dataset. Additionally, partial volume effects and Gaussian noise were integrated. The simulated 4D MRA was visually inspected and regarded as similar to clinical data. Finally, phantom datasets with different vessel diameter and signal-to-noise ratio are computed. Three state-of-the-art methods were used to extract BAT values. Computed and known values were compared. The results suggest that model-dependent approaches perform better than the model-independent method.

M3 - SCORING: Zeitschriftenaufsatz

VL - 160

SP - 1263

EP - 1267

IS - 2

M1 - 2