Erste Erfahrungen mit der Mehrzeilendetektorspiral-CT in der Diagnostik der Arteriosklerose der Koronargefässe
Standard
Erste Erfahrungen mit der Mehrzeilendetektorspiral-CT in der Diagnostik der Arteriosklerose der Koronargefässe. / Becker, C R; Knez, A; Leber, A; Hong, C; Treede, H; Wildhirt, S; Ohnesorge, B; Flohr, T; Schoepf, U J; Reiser, M F.
in: RADIOLOGE, Jahrgang 40, Nr. 2, 02.2000, S. 118-122.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Erste Erfahrungen mit der Mehrzeilendetektorspiral-CT in der Diagnostik der Arteriosklerose der Koronargefässe
AU - Becker, C R
AU - Knez, A
AU - Leber, A
AU - Hong, C
AU - Treede, H
AU - Wildhirt, S
AU - Ohnesorge, B
AU - Flohr, T
AU - Schoepf, U J
AU - Reiser, M F
PY - 2000/2
Y1 - 2000/2
N2 - PURPOSE: Multi-row-detector-spiral-CT (MSCT) allows for 250 ms effective exposure time. The purpose of this study was to demonstrate the possibilities and limitations of this CT technology for non enhanced and contrast enhanced investigation of the coronary arteries.METHODS: Investigation of the coronary arteries without contrast medium for quantification of coronary calcifications was performed in an obese patient (140 kg) with MSCT and electron beam CT (EBCT). In 56 patients contrast enhanced CT angiography of the coronary arteries was performed to determine image quality depending on the heart rate.RESULTS: In the obese patient superior image quality could be achieved with MSCT allowing for reliable quantification of coronary calcifications. With MSCT angiography of the coronary arteries good image quality was achieved in patients with a heart rate of 59 +/- 8 beats per minute.CONCLUSION: Even if there are limitations in patients with higher heart rates with an effective exposure time of 250 ms MSCT has clear advantage of image quality in the assessment of non enhanced and contrast enhanced coronary arteries.
AB - PURPOSE: Multi-row-detector-spiral-CT (MSCT) allows for 250 ms effective exposure time. The purpose of this study was to demonstrate the possibilities and limitations of this CT technology for non enhanced and contrast enhanced investigation of the coronary arteries.METHODS: Investigation of the coronary arteries without contrast medium for quantification of coronary calcifications was performed in an obese patient (140 kg) with MSCT and electron beam CT (EBCT). In 56 patients contrast enhanced CT angiography of the coronary arteries was performed to determine image quality depending on the heart rate.RESULTS: In the obese patient superior image quality could be achieved with MSCT allowing for reliable quantification of coronary calcifications. With MSCT angiography of the coronary arteries good image quality was achieved in patients with a heart rate of 59 +/- 8 beats per minute.CONCLUSION: Even if there are limitations in patients with higher heart rates with an effective exposure time of 250 ms MSCT has clear advantage of image quality in the assessment of non enhanced and contrast enhanced coronary arteries.
KW - Adult
KW - Aged
KW - Calcinosis/diagnostic imaging
KW - Coronary Angiography/instrumentation
KW - Coronary Artery Disease/diagnostic imaging
KW - Equipment Design
KW - Female
KW - Heart Rate/physiology
KW - Humans
KW - Image Processing, Computer-Assisted/instrumentation
KW - Male
KW - Middle Aged
KW - Obesity/diagnostic imaging
KW - Radiographic Image Enhancement/instrumentation
KW - Sensitivity and Specificity
KW - Tomography, X-Ray Computed/instrumentation
U2 - 10.1007/s001170050019
DO - 10.1007/s001170050019
M3 - SCORING: Zeitschriftenaufsatz
C2 - 10758624
VL - 40
SP - 118
EP - 122
JO - RADIOLOGE
JF - RADIOLOGE
SN - 0033-832X
IS - 2
ER -