[Endoscopic imaging of vocal cord vibrations. Digital high speed recording with various systems]

Standard

[Endoscopic imaging of vocal cord vibrations. Digital high speed recording with various systems]. / Hess, Markus; Herzel, H; Köster, O; Scheurich, F; Gross, M.

in: HNO, Jahrgang 44, Nr. 12, 12, 1996, S. 685-693.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Hess M, Herzel H, Köster O, Scheurich F, Gross M. [Endoscopic imaging of vocal cord vibrations. Digital high speed recording with various systems]. HNO. 1996;44(12):685-693. 12.

Bibtex

@article{1349d57edced486b8bbdfa059044c412,
title = "[Endoscopic imaging of vocal cord vibrations. Digital high speed recording with various systems]",
abstract = "Vocal fold vibration patterns during phonation are presented with different digital imaging systems. With newly developed technical equipment color images up to 1000 digital images/s were obtained without light intensifying enhancement techniques via rigid and flexible endoscopy. With this color high-speed system, morphologic structures, such as small blood vessels, were visualized in high-resolution quality as a result of additional color information. In another system, zooming of endoscopic pictures via pixel interpolation algorithms provided full-monitor presentation of vocal fold vibratory patterns. This system allows PC-based synchronization with microphone and electroglottographic signals in a frame-by-frame technique. Although only processing gray scale images, analyses of dynamic changes in modes of vibration were facilitated by the higher frame rate recording of up to 2000 frames/s and, in addition, they display corresponding analog signals. Both methods provide clinically important information. Furthermore, we demonstrated irregular vocal fold vibration patterns in a healthy adult volunteer. In this experiment, the irregular vibratory modes were induced by voluntarily applying asymmetric vocal fold tension. The asymmetric vocal fold vibration pattern resulted in (functionally induced) roughness of the voice as predicted by computer models of asymmetric vocal fold vibration. Digital high-speed cinematography proved to be a highly promising technique in the analysis of dysphonia and provided physiological examples that could be compared with models of coupled nonlinear oscillators.",
author = "Markus Hess and H Herzel and O K{\"o}ster and F Scheurich and M Gross",
year = "1996",
language = "Deutsch",
volume = "44",
pages = "685--693",
journal = "HNO",
issn = "0017-6192",
publisher = "Springer",
number = "12",

}

RIS

TY - JOUR

T1 - [Endoscopic imaging of vocal cord vibrations. Digital high speed recording with various systems]

AU - Hess, Markus

AU - Herzel, H

AU - Köster, O

AU - Scheurich, F

AU - Gross, M

PY - 1996

Y1 - 1996

N2 - Vocal fold vibration patterns during phonation are presented with different digital imaging systems. With newly developed technical equipment color images up to 1000 digital images/s were obtained without light intensifying enhancement techniques via rigid and flexible endoscopy. With this color high-speed system, morphologic structures, such as small blood vessels, were visualized in high-resolution quality as a result of additional color information. In another system, zooming of endoscopic pictures via pixel interpolation algorithms provided full-monitor presentation of vocal fold vibratory patterns. This system allows PC-based synchronization with microphone and electroglottographic signals in a frame-by-frame technique. Although only processing gray scale images, analyses of dynamic changes in modes of vibration were facilitated by the higher frame rate recording of up to 2000 frames/s and, in addition, they display corresponding analog signals. Both methods provide clinically important information. Furthermore, we demonstrated irregular vocal fold vibration patterns in a healthy adult volunteer. In this experiment, the irregular vibratory modes were induced by voluntarily applying asymmetric vocal fold tension. The asymmetric vocal fold vibration pattern resulted in (functionally induced) roughness of the voice as predicted by computer models of asymmetric vocal fold vibration. Digital high-speed cinematography proved to be a highly promising technique in the analysis of dysphonia and provided physiological examples that could be compared with models of coupled nonlinear oscillators.

AB - Vocal fold vibration patterns during phonation are presented with different digital imaging systems. With newly developed technical equipment color images up to 1000 digital images/s were obtained without light intensifying enhancement techniques via rigid and flexible endoscopy. With this color high-speed system, morphologic structures, such as small blood vessels, were visualized in high-resolution quality as a result of additional color information. In another system, zooming of endoscopic pictures via pixel interpolation algorithms provided full-monitor presentation of vocal fold vibratory patterns. This system allows PC-based synchronization with microphone and electroglottographic signals in a frame-by-frame technique. Although only processing gray scale images, analyses of dynamic changes in modes of vibration were facilitated by the higher frame rate recording of up to 2000 frames/s and, in addition, they display corresponding analog signals. Both methods provide clinically important information. Furthermore, we demonstrated irregular vocal fold vibration patterns in a healthy adult volunteer. In this experiment, the irregular vibratory modes were induced by voluntarily applying asymmetric vocal fold tension. The asymmetric vocal fold vibration pattern resulted in (functionally induced) roughness of the voice as predicted by computer models of asymmetric vocal fold vibration. Digital high-speed cinematography proved to be a highly promising technique in the analysis of dysphonia and provided physiological examples that could be compared with models of coupled nonlinear oscillators.

M3 - SCORING: Zeitschriftenaufsatz

VL - 44

SP - 685

EP - 693

JO - HNO

JF - HNO

SN - 0017-6192

IS - 12

M1 - 12

ER -