Ecological validity of walking capacity tests in multiple sclerosis

  • J P Stellmann
  • A Neuhaus
  • Iris N Götze
  • S Briken
  • C Lederer
  • M Schimpl
  • C Heesen
  • M Daumer

Abstract

BACKGROUND: Ecological validity implicates in how far clinical assessments refer to real life. Short clinical gait tests up to ten meters and 2- or 6-Minutes Walking Tests (2MWT/6MWT) are used as performance-based outcomes in Multiple Sclerosis (MS) studies and considered as moderately associated with real life mobility.

OBJECTIVE: To investigate the ecological validity of 10 Meter Walking Test (10mWT), 2MWT and 6MWT.

METHODS: Persons with MS performed 10mWT, 6MWT including 2MWT and 7 recorded days by accelerometry. Ecological validity was assumed if walking tests represented a typical walking sequence in real-life and correlations with accelerometry parameters were strong.

RESULTS: In this cohort (n=28, medians: age=45, EDSS=3.2, disease duration=9 years), uninterrupted walking of 2 or 6 minutes occurred not frequent in real life (2.61 and 0.35 sequences/day). 10mWT correlated only with slow walking speed quantiles in real life. 2MWT and 6MWT correlated moderately with most real life walking parameters.

CONCLUSION: Clinical gait tests over a few meters have a poor ecological validity while validity is moderate for 2MWT and 6MWT. Mobile accelerometry offers the opportunity to control and improve the ecological validity of MS mobility outcomes.