Early experience with bridging stent graft deployment without sheath support in branched and fenestrated endovascular aortic repair

Standard

Early experience with bridging stent graft deployment without sheath support in branched and fenestrated endovascular aortic repair. / Sotir, Anna; Klopf, Johannes; Wolf, Florian; Funovics, Martin A; Loewe, Christian; Kölbel, Tilo; Neumayer, Christoph; Eilenberg, Wolf.

in: J VASC SURG, Jahrgang 78, Nr. 6, 12.2023, S. 1383-1391.e5.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{fc9de062fcae4d8ca71093c0c2796357,
title = "Early experience with bridging stent graft deployment without sheath support in branched and fenestrated endovascular aortic repair",
abstract = "OBJECTIVE: To assess the early experience with modified version of simplified bare-wire target vessel (SMART) technique, implying delivery of bridging stent grafts without historically established sheath support, and to compare its outcome to standard endovascular aortic repair procedures with fenestrated/branched devices.METHODS: A retrospective analysis of 102 consecutive patients treated with fenestrated/branched devices from January 2020 to December 2022 was undertaken. The study population was divided into three groups-a sheath group (SG), SMART group, and nonsheath group (NSG). Primary end points were radiation exposure (dose-area product), fluoroscopy time, dose of contrast agent, operation time, and incidence of intraoperative target vessel (TV) complications and additional procedures. Freedom from secondary TV related reinterventions at the three follow-up phases were defined as secondary end points.RESULTS: A total of 183 TVs (38.8% visceral arteries [VA]; 56.3% renal arteries [RA]) in the SG, 36 TVs (44.4% VA, 55.6% RA) in the SMART group, and 168 TVs (47.6% VA; 50% RA) in the NSG were accessed. The mean number of fenestrations and bridging stent grafts was equally distributed in all three groups. The SMART group only included cases treated with fenestrated devices. The dose-area product was significantly lower in the SMART (median, 203 Gy × cm2; interquartile range [IQR], 179-365 Gy × cm2) and NSG (median, 340 Gy × cm2; IQR, 220-651 Gy × cm2) groups vs the SG (median, 464 Gy × cm2; IQR, 267-871 Gy × cm2; P = .007). Operation time was also significantly lower in the NSG (median, 265 minutes; IQR, 221-337 minutes) and SMART (median, 292 minutes; IQR, 234-351 minutes) groups vs the SG (median, 326 minutes; IQR, 277-375 minutes; P = .004), respectively. Intraoperative TV-related complications were most frequently observed in the SG (9/183 TVs; P = .008).CONCLUSIONS: This study reports the outcomes of three currently available TV stenting approaches. Previously reported SMART technique, and its modified version (NSG) proved to be a safe alternative to historically established TV stenting technique with sheath support (SG).",
keywords = "Humans, Endovascular Aneurysm Repair, Retrospective Studies, Stents, Contrast Media, Fluoroscopy, Intraoperative Complications",
author = "Anna Sotir and Johannes Klopf and Florian Wolf and Funovics, {Martin A} and Christian Loewe and Tilo K{\"o}lbel and Christoph Neumayer and Wolf Eilenberg",
note = "Copyright {\textcopyright} 2023 The Authors. Published by Elsevier Inc. All rights reserved.",
year = "2023",
month = dec,
doi = "10.1016/j.jvs.2023.05.054",
language = "English",
volume = "78",
pages = "1383--1391.e5",
journal = "J VASC SURG",
issn = "0741-5214",
publisher = "Mosby Inc.",
number = "6",

}

RIS

TY - JOUR

T1 - Early experience with bridging stent graft deployment without sheath support in branched and fenestrated endovascular aortic repair

AU - Sotir, Anna

AU - Klopf, Johannes

AU - Wolf, Florian

AU - Funovics, Martin A

AU - Loewe, Christian

AU - Kölbel, Tilo

AU - Neumayer, Christoph

AU - Eilenberg, Wolf

N1 - Copyright © 2023 The Authors. Published by Elsevier Inc. All rights reserved.

PY - 2023/12

Y1 - 2023/12

N2 - OBJECTIVE: To assess the early experience with modified version of simplified bare-wire target vessel (SMART) technique, implying delivery of bridging stent grafts without historically established sheath support, and to compare its outcome to standard endovascular aortic repair procedures with fenestrated/branched devices.METHODS: A retrospective analysis of 102 consecutive patients treated with fenestrated/branched devices from January 2020 to December 2022 was undertaken. The study population was divided into three groups-a sheath group (SG), SMART group, and nonsheath group (NSG). Primary end points were radiation exposure (dose-area product), fluoroscopy time, dose of contrast agent, operation time, and incidence of intraoperative target vessel (TV) complications and additional procedures. Freedom from secondary TV related reinterventions at the three follow-up phases were defined as secondary end points.RESULTS: A total of 183 TVs (38.8% visceral arteries [VA]; 56.3% renal arteries [RA]) in the SG, 36 TVs (44.4% VA, 55.6% RA) in the SMART group, and 168 TVs (47.6% VA; 50% RA) in the NSG were accessed. The mean number of fenestrations and bridging stent grafts was equally distributed in all three groups. The SMART group only included cases treated with fenestrated devices. The dose-area product was significantly lower in the SMART (median, 203 Gy × cm2; interquartile range [IQR], 179-365 Gy × cm2) and NSG (median, 340 Gy × cm2; IQR, 220-651 Gy × cm2) groups vs the SG (median, 464 Gy × cm2; IQR, 267-871 Gy × cm2; P = .007). Operation time was also significantly lower in the NSG (median, 265 minutes; IQR, 221-337 minutes) and SMART (median, 292 minutes; IQR, 234-351 minutes) groups vs the SG (median, 326 minutes; IQR, 277-375 minutes; P = .004), respectively. Intraoperative TV-related complications were most frequently observed in the SG (9/183 TVs; P = .008).CONCLUSIONS: This study reports the outcomes of three currently available TV stenting approaches. Previously reported SMART technique, and its modified version (NSG) proved to be a safe alternative to historically established TV stenting technique with sheath support (SG).

AB - OBJECTIVE: To assess the early experience with modified version of simplified bare-wire target vessel (SMART) technique, implying delivery of bridging stent grafts without historically established sheath support, and to compare its outcome to standard endovascular aortic repair procedures with fenestrated/branched devices.METHODS: A retrospective analysis of 102 consecutive patients treated with fenestrated/branched devices from January 2020 to December 2022 was undertaken. The study population was divided into three groups-a sheath group (SG), SMART group, and nonsheath group (NSG). Primary end points were radiation exposure (dose-area product), fluoroscopy time, dose of contrast agent, operation time, and incidence of intraoperative target vessel (TV) complications and additional procedures. Freedom from secondary TV related reinterventions at the three follow-up phases were defined as secondary end points.RESULTS: A total of 183 TVs (38.8% visceral arteries [VA]; 56.3% renal arteries [RA]) in the SG, 36 TVs (44.4% VA, 55.6% RA) in the SMART group, and 168 TVs (47.6% VA; 50% RA) in the NSG were accessed. The mean number of fenestrations and bridging stent grafts was equally distributed in all three groups. The SMART group only included cases treated with fenestrated devices. The dose-area product was significantly lower in the SMART (median, 203 Gy × cm2; interquartile range [IQR], 179-365 Gy × cm2) and NSG (median, 340 Gy × cm2; IQR, 220-651 Gy × cm2) groups vs the SG (median, 464 Gy × cm2; IQR, 267-871 Gy × cm2; P = .007). Operation time was also significantly lower in the NSG (median, 265 minutes; IQR, 221-337 minutes) and SMART (median, 292 minutes; IQR, 234-351 minutes) groups vs the SG (median, 326 minutes; IQR, 277-375 minutes; P = .004), respectively. Intraoperative TV-related complications were most frequently observed in the SG (9/183 TVs; P = .008).CONCLUSIONS: This study reports the outcomes of three currently available TV stenting approaches. Previously reported SMART technique, and its modified version (NSG) proved to be a safe alternative to historically established TV stenting technique with sheath support (SG).

KW - Humans

KW - Endovascular Aneurysm Repair

KW - Retrospective Studies

KW - Stents

KW - Contrast Media

KW - Fluoroscopy

KW - Intraoperative Complications

U2 - 10.1016/j.jvs.2023.05.054

DO - 10.1016/j.jvs.2023.05.054

M3 - SCORING: Journal article

C2 - 37330151

VL - 78

SP - 1383-1391.e5

JO - J VASC SURG

JF - J VASC SURG

SN - 0741-5214

IS - 6

ER -