Detection of brain lesions after catheter ablation depends on imaging criteria: insights from AXAFA-AFNET 5 trial

  • Karl Georg Haeusler
  • Felizitas A Eichner
  • Peter U Heuschmann
  • Jochen B Fiebach
  • Tobias Engelhorn
  • David Callans
  • Tom De Potter
  • Philippe Debruyne
  • Daniel Scherr
  • Gerhard Hindricks
  • Hussein R Al-Khalidi
  • Lluis Mont
  • Won Yong Kim
  • Jonathan P Piccini
  • Ulrich Schotten
  • Sakis Themistoclakis
  • Luigi Di Biase
  • Paulus Kirchhof

Beteiligte Einrichtungen

Abstract

AIMS: Left atrial catheter ablation is well established in patients with symptomatic atrial fibrillation (AF) but associated with risk of embolism to the brain. The present analysis aims to assess the impact of diffusion-weighted imaging (DWI) slice thickness on the rate of magnetic resonance imaging (MRI)-detected ischaemic brain lesions after ablation.

METHODS AND RESULTS: AXAFA-AFNET 5 trial (NCT02227550) participants underwent MRI using high-resolution (hr) DWI (slice thickness: 2.5-3 mm) and standard DWI (slice thickness: 5-6 mm) within 3-48 h after ablation. In 321 patients with analysable brain MRI (mean age 64 years, 33% female, median CHA2DS2-VASc 2), hrDWI detected at least one acute brain lesion in 84 (26.2%) patients and standard DWI in 60 (18.7%; P < 0.01) patients. High-resolution diffusion-weighted imaging detected more lesions compared to standard DWI (165 vs. 104; P < 0.01). The degree of agreement for lesion confirmation using hrDWI vs. standard DWI was substantial (κ = 0769). Comparing the proportion of DWI-detected lesions, lesion distribution, and total lesion volume per patient, there was no difference in the cohort of participants undergoing MRI at 1.5 T (n = 52) vs. 3 T (n = 269).

CONCLUSION: The pre-specified AXAFA-AFNET 5 sub-analysis revealed significantly increased rates of MRI-detected acute brain lesions using hrDWI instead of standard DWI in AF patients undergoing ablation. In comparison to DWI slice thickness, MRI field strength had a no significant impact in the trial. Comparing the varying rates of ablation-related MRI-detected brain lesions across previous studies has to consider these technical parameters. Future studies should use hrDWI, as feasibility was demonstrated in the multicentre AXAFA-AFNET 5 trial.

Bibliografische Daten

OriginalspracheEnglisch
Aufsatznummereuad323
ISSN1099-5129
DOIs
StatusVeröffentlicht - 06.12.2023

Anmerkungen des Dekanats

© The Author(s) 2023. Published by Oxford University Press on behalf of the European Society of Cardiology.

PubMed 37897713