Data from: Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom

Standard

Data from: Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom. / Ashtarayeh, Mohammad.

in: SCI DATA, 2020.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungAndere (Vorworte u.ä.)Forschung

Harvard

APA

Vancouver

Bibtex

@article{84921f07d2414392a9b9d2b83a3fbb7d,
title = "Data from: Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom",
abstract = "Here, we present an extension to our previously published structural ultrahigh resolution T1-weighted magnetic resonance imaging (MRI) dataset with an isotropic resolution of 250 µm, consisting of multiple additional ultrahigh resolution contrasts. Included are up to 150 µm Time-of-Flight angiography, an updated 250 µm structural T1-weighted reconstruction, 330 µm quantitative susceptibility mapping, up to 450 µm structural T2-weighted imaging, 700 µm T1-weighted back-to-back scans, 800 µm diffusion tensor imaging, one hour continuous resting-state functional MRI with an isotropic spatial resolution of 1.8 mm as well as more than 120 other structural T1-weighted volumes together with multiple corresponding proton density weighted acquisitions collected over ten years. All data are from the same participant and were acquired on the same 7 T scanner. The repository contains the unprocessed data as well as (pre-)processing results. The data were acquired in multiple studies with individual goals. This is a unique and comprehensive collection comprising a “human phantom” dataset. Therefore, we compiled, processed, and structured the data, making them publicly available for further investigation.",
author = "Mohammad Ashtarayeh",
year = "2020",
language = "English",
journal = "SCI DATA",
issn = "2052-4463",
publisher = "NATURE PUBLISHING GROUP",

}

RIS

TY - JOUR

T1 - Data from: Comprehensive ultrahigh resolution whole brain in vivo MRI dataset as a human phantom

AU - Ashtarayeh, Mohammad

PY - 2020

Y1 - 2020

N2 - Here, we present an extension to our previously published structural ultrahigh resolution T1-weighted magnetic resonance imaging (MRI) dataset with an isotropic resolution of 250 µm, consisting of multiple additional ultrahigh resolution contrasts. Included are up to 150 µm Time-of-Flight angiography, an updated 250 µm structural T1-weighted reconstruction, 330 µm quantitative susceptibility mapping, up to 450 µm structural T2-weighted imaging, 700 µm T1-weighted back-to-back scans, 800 µm diffusion tensor imaging, one hour continuous resting-state functional MRI with an isotropic spatial resolution of 1.8 mm as well as more than 120 other structural T1-weighted volumes together with multiple corresponding proton density weighted acquisitions collected over ten years. All data are from the same participant and were acquired on the same 7 T scanner. The repository contains the unprocessed data as well as (pre-)processing results. The data were acquired in multiple studies with individual goals. This is a unique and comprehensive collection comprising a “human phantom” dataset. Therefore, we compiled, processed, and structured the data, making them publicly available for further investigation.

AB - Here, we present an extension to our previously published structural ultrahigh resolution T1-weighted magnetic resonance imaging (MRI) dataset with an isotropic resolution of 250 µm, consisting of multiple additional ultrahigh resolution contrasts. Included are up to 150 µm Time-of-Flight angiography, an updated 250 µm structural T1-weighted reconstruction, 330 µm quantitative susceptibility mapping, up to 450 µm structural T2-weighted imaging, 700 µm T1-weighted back-to-back scans, 800 µm diffusion tensor imaging, one hour continuous resting-state functional MRI with an isotropic spatial resolution of 1.8 mm as well as more than 120 other structural T1-weighted volumes together with multiple corresponding proton density weighted acquisitions collected over ten years. All data are from the same participant and were acquired on the same 7 T scanner. The repository contains the unprocessed data as well as (pre-)processing results. The data were acquired in multiple studies with individual goals. This is a unique and comprehensive collection comprising a “human phantom” dataset. Therefore, we compiled, processed, and structured the data, making them publicly available for further investigation.

M3 - Other (editorial matter etc.)

JO - SCI DATA

JF - SCI DATA

SN - 2052-4463

M1 - 138 (2021)

ER -