Clinical risk assessment of biotin interference with a high-sensitivity cardiac troponin T assay
Standard
Clinical risk assessment of biotin interference with a high-sensitivity cardiac troponin T assay. / Mumma, Bryn; Diercks, Deborah; Twerenbold, Raphael; Valcour, André; Ziegler, André; Schützenmeister, André; Kasapic, Dusanka; Tran, Nam.
in: CLIN CHEM LAB MED, Jahrgang 58, Nr. 11, 25.10.2020, S. 1931-1940.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Clinical risk assessment of biotin interference with a high-sensitivity cardiac troponin T assay
AU - Mumma, Bryn
AU - Diercks, Deborah
AU - Twerenbold, Raphael
AU - Valcour, André
AU - Ziegler, André
AU - Schützenmeister, André
AU - Kasapic, Dusanka
AU - Tran, Nam
PY - 2020/10/25
Y1 - 2020/10/25
N2 - Objectives Biotin >20.0 ng/mL (81.8 nmol/L) can reduce Elecsys® Troponin T Gen 5 (TnT Gen 5; Roche Diagnostics) assay recovery, potentially leading to false-negative results in patients with suspected acute myocardial infarction (AMI). We aimed to determine the prevalence of elevated biotin and AMI misclassification risk from biotin interference with the TnT Gen 5 assay. Methods Biotin was measured using an Elecsys assay in two cohorts: (i) 797 0-h and 646 3-h samples from 850 US emergency department patients with suspected acute coronary syndrome (ACS); (ii) 2023 random samples from a US laboratory network, in which biotin distributions were extrapolated for higher values using pharmacokinetic modeling. Biotin >20.0 ng/mL (81.8 nmol/L) prevalence and biotin 99th percentile values were calculated. AMI misclassification risk due to biotin interference with the TnT Gen 5 assay was modeled using different assay cutoffs and test timepoints. Results ACS cohort: 1/797 (0.13%) 0-h and 1/646 (0.15%) 3-h samples had biotin >20.0 ng/mL (81.8 nmol/L); 99th percentile biotin was 2.62 ng/mL (10.7 nmol/L; 0-h) and 2.38 ng/mL (9.74 nmol/L; 3-h). Using conservative assumptions, the likelihood of false-negative AMI prediction due to biotin interference was 0.026% (0-h result; 19 ng/L TnT Gen 5 assay cutoff). US laboratory cohort: 15/2023 (0.74%) samples had biotin >20.0 ng/mL (81.8 nmol/L); 99th percentile biotin was 16.6 ng/mL (68.0 nmol/L). Misclassification risk due to biotin interference (19 ng/L TnT Gen 5 assay cutoff) was 0.025% (0-h), 0.0064% (1-h), 0.00048% (3-h), and <0.00001% (6-h). Conclusions Biotin interference has minimal impact on the TnT Gen 5 assay's clinical utility, and the likelihood of false-negative AMI prediction is extremely low.
AB - Objectives Biotin >20.0 ng/mL (81.8 nmol/L) can reduce Elecsys® Troponin T Gen 5 (TnT Gen 5; Roche Diagnostics) assay recovery, potentially leading to false-negative results in patients with suspected acute myocardial infarction (AMI). We aimed to determine the prevalence of elevated biotin and AMI misclassification risk from biotin interference with the TnT Gen 5 assay. Methods Biotin was measured using an Elecsys assay in two cohorts: (i) 797 0-h and 646 3-h samples from 850 US emergency department patients with suspected acute coronary syndrome (ACS); (ii) 2023 random samples from a US laboratory network, in which biotin distributions were extrapolated for higher values using pharmacokinetic modeling. Biotin >20.0 ng/mL (81.8 nmol/L) prevalence and biotin 99th percentile values were calculated. AMI misclassification risk due to biotin interference with the TnT Gen 5 assay was modeled using different assay cutoffs and test timepoints. Results ACS cohort: 1/797 (0.13%) 0-h and 1/646 (0.15%) 3-h samples had biotin >20.0 ng/mL (81.8 nmol/L); 99th percentile biotin was 2.62 ng/mL (10.7 nmol/L; 0-h) and 2.38 ng/mL (9.74 nmol/L; 3-h). Using conservative assumptions, the likelihood of false-negative AMI prediction due to biotin interference was 0.026% (0-h result; 19 ng/L TnT Gen 5 assay cutoff). US laboratory cohort: 15/2023 (0.74%) samples had biotin >20.0 ng/mL (81.8 nmol/L); 99th percentile biotin was 16.6 ng/mL (68.0 nmol/L). Misclassification risk due to biotin interference (19 ng/L TnT Gen 5 assay cutoff) was 0.025% (0-h), 0.0064% (1-h), 0.00048% (3-h), and <0.00001% (6-h). Conclusions Biotin interference has minimal impact on the TnT Gen 5 assay's clinical utility, and the likelihood of false-negative AMI prediction is extremely low.
KW - Acute Coronary Syndrome/diagnosis
KW - Biomarkers/blood
KW - Biotin/blood
KW - Cohort Studies
KW - Diagnostic Tests, Routine
KW - False Negative Reactions
KW - Female
KW - Humans
KW - Immunoassay
KW - Immunologic Tests
KW - Male
KW - Middle Aged
KW - Myocardial Infarction/diagnosis
KW - Risk Assessment
KW - Troponin T/blood
U2 - 10.1515/cclm-2019-0962
DO - 10.1515/cclm-2019-0962
M3 - SCORING: Journal article
C2 - 32804676
VL - 58
SP - 1931
EP - 1940
JO - CLIN CHEM LAB MED
JF - CLIN CHEM LAB MED
SN - 1434-6621
IS - 11
ER -