Clinical performance of zirconia implant abutments luted to a titanium base - a retrospective cross-sectional study

Standard

Clinical performance of zirconia implant abutments luted to a titanium base - a retrospective cross-sectional study. / Happe, Arndt; von Glasser, Gerrit Schulze; Neugebauer, Jörg; Strick, Kilian; Smeets, Ralf; Rutkowski, Rico.

in: INT J COMPUT DENT, Jahrgang 25, Nr. 1, 24.03.2022, S. 37-45.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{7a977a7e73d9480197ee350e4712a8e6,
title = "Clinical performance of zirconia implant abutments luted to a titanium base - a retrospective cross-sectional study",
abstract = "AIM: To evaluate the survival of implant-retained restorations fabricated on CAD/CAM-derived zirconia abutments luted to a titanium base.MATERIALS AND METHODS: 153 patients who received a total of 310 dental implants (Camlog Promote plus or Xive S) and all-ceramic restorations on yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) abutments luted to a titanium base during the last 10 years were included. Patients were examined for technical complications during routine visits. Crestal bone level changes were randomly analyzed based on periapical radiographs of 75 implants.RESULTS: Among the included 153 patients, 17 ceramic chippings (5.5%), 6 abutment loosenings (1.9%), and 2 abutment fractures (0.6%) were identified. The mean follow-up time was 4.7 years (standard deviation [SD]: 1.94), with a follow-up period of up to 10 years (maximum). Kaplan-Meier estimation resulted in a survival rate without complications of 91.6% for the restoration and 97.4% for the abutment. There was no statistically significant difference between the two implant systems, either between implant location or regarding the complication rate of the type of restoration. For the 75 implants included in the radiographic analysis, the mean bone level change was 0.384 mm (SD: 0.242, 95% CI: 0.315 to 0.452) for the Camlog implant system and 0.585 mm (SD: 0.366, 95% CI: 0.434 to 0.736) for the Xive system (P = 0.007).CONCLUSION: The results of the present retrospective study demonstrate acceptable clinical outcomes for zirconia abutments luted to a titanium base in combination with all-ceramic restorations. The assessed abutment design does not appear to have a negative impact on peri-implant hard tissue.",
keywords = "Cross-Sectional Studies, Dental Implants, Humans, Retrospective Studies, Titanium/chemistry, Zirconium",
author = "Arndt Happe and {von Glasser}, {Gerrit Schulze} and J{\"o}rg Neugebauer and Kilian Strick and Ralf Smeets and Rico Rutkowski",
year = "2022",
month = mar,
day = "24",
language = "English",
volume = "25",
pages = "37--45",
journal = "INT J COMPUT DENT",
issn = "1463-4201",
publisher = "Quintessenz Verlags-GmbH",
number = "1",

}

RIS

TY - JOUR

T1 - Clinical performance of zirconia implant abutments luted to a titanium base - a retrospective cross-sectional study

AU - Happe, Arndt

AU - von Glasser, Gerrit Schulze

AU - Neugebauer, Jörg

AU - Strick, Kilian

AU - Smeets, Ralf

AU - Rutkowski, Rico

PY - 2022/3/24

Y1 - 2022/3/24

N2 - AIM: To evaluate the survival of implant-retained restorations fabricated on CAD/CAM-derived zirconia abutments luted to a titanium base.MATERIALS AND METHODS: 153 patients who received a total of 310 dental implants (Camlog Promote plus or Xive S) and all-ceramic restorations on yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) abutments luted to a titanium base during the last 10 years were included. Patients were examined for technical complications during routine visits. Crestal bone level changes were randomly analyzed based on periapical radiographs of 75 implants.RESULTS: Among the included 153 patients, 17 ceramic chippings (5.5%), 6 abutment loosenings (1.9%), and 2 abutment fractures (0.6%) were identified. The mean follow-up time was 4.7 years (standard deviation [SD]: 1.94), with a follow-up period of up to 10 years (maximum). Kaplan-Meier estimation resulted in a survival rate without complications of 91.6% for the restoration and 97.4% for the abutment. There was no statistically significant difference between the two implant systems, either between implant location or regarding the complication rate of the type of restoration. For the 75 implants included in the radiographic analysis, the mean bone level change was 0.384 mm (SD: 0.242, 95% CI: 0.315 to 0.452) for the Camlog implant system and 0.585 mm (SD: 0.366, 95% CI: 0.434 to 0.736) for the Xive system (P = 0.007).CONCLUSION: The results of the present retrospective study demonstrate acceptable clinical outcomes for zirconia abutments luted to a titanium base in combination with all-ceramic restorations. The assessed abutment design does not appear to have a negative impact on peri-implant hard tissue.

AB - AIM: To evaluate the survival of implant-retained restorations fabricated on CAD/CAM-derived zirconia abutments luted to a titanium base.MATERIALS AND METHODS: 153 patients who received a total of 310 dental implants (Camlog Promote plus or Xive S) and all-ceramic restorations on yttria-stabilized tetragonal zirconia polycrystal (3Y-TZP) abutments luted to a titanium base during the last 10 years were included. Patients were examined for technical complications during routine visits. Crestal bone level changes were randomly analyzed based on periapical radiographs of 75 implants.RESULTS: Among the included 153 patients, 17 ceramic chippings (5.5%), 6 abutment loosenings (1.9%), and 2 abutment fractures (0.6%) were identified. The mean follow-up time was 4.7 years (standard deviation [SD]: 1.94), with a follow-up period of up to 10 years (maximum). Kaplan-Meier estimation resulted in a survival rate without complications of 91.6% for the restoration and 97.4% for the abutment. There was no statistically significant difference between the two implant systems, either between implant location or regarding the complication rate of the type of restoration. For the 75 implants included in the radiographic analysis, the mean bone level change was 0.384 mm (SD: 0.242, 95% CI: 0.315 to 0.452) for the Camlog implant system and 0.585 mm (SD: 0.366, 95% CI: 0.434 to 0.736) for the Xive system (P = 0.007).CONCLUSION: The results of the present retrospective study demonstrate acceptable clinical outcomes for zirconia abutments luted to a titanium base in combination with all-ceramic restorations. The assessed abutment design does not appear to have a negative impact on peri-implant hard tissue.

KW - Cross-Sectional Studies

KW - Dental Implants

KW - Humans

KW - Retrospective Studies

KW - Titanium/chemistry

KW - Zirconium

M3 - SCORING: Journal article

C2 - 35322651

VL - 25

SP - 37

EP - 45

JO - INT J COMPUT DENT

JF - INT J COMPUT DENT

SN - 1463-4201

IS - 1

ER -