Clinical evaluation of a SARS-CoV-2 RT-PCR assay on a fully automated system for rapid on-demand testing in the hospital setting

Standard

Clinical evaluation of a SARS-CoV-2 RT-PCR assay on a fully automated system for rapid on-demand testing in the hospital setting. / Nörz, Dominik; Fischer, Nicole; Schultze, Alexander; Kluge, Stefan; Mayer-Runge, Ulrich; Aepfelbacher, Martin; Pfefferle, Susanne; Lütgehetmann, Marc.

in: J CLIN VIROL, Jahrgang 128, 07.2020, S. 104390.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{5d3b81bea8194fd7bb039c0beb391299,
title = "Clinical evaluation of a SARS-CoV-2 RT-PCR assay on a fully automated system for rapid on-demand testing in the hospital setting",
abstract = "BACKGROUND: The ongoing SARS-CoV-2 pandemic presents a unique challenge for diagnostic laboratories around the world. Automation of workflows in molecular diagnostics is instrumental for coping with the large number of tests ordered by clinicians, as well as providing fast-tracked rapid testing for highly urgent cases. In this study we evaluated a SARS-CoV-2 LDT for the NeuMoDx 96 system, a fully automated device performing extraction and real-time PCR.METHODS: A publicly available SARS-CoV-2 RT-PCR assay was adapted for the automated system. Analytical performance was evaluated using in-vitro transcribed RNA and clinical performance was compared to the cobas 6800-based reference assay within the lab.RESULTS: The Envelope (E) Gene-LDT displayed good analytical performance with an LoD of 95.55 cp/mL and no false positives during evaluation of cross-reactivity. A total of 176 patient samples were tested with both the E-Gene-LDT and the reference assay. Positive and negative agreement were 100 % and 99.2 % respectively. Invalid-rate was 6.3 %.CONCLUSION: The E-Gene-LDT showed analytical and clinical performance comparable to the cobas6800-based reference assay. Due to its random-access workflow concept and rapid time-to-result of about 80 min, the system is very well suited for providing fast-tracked SARS-CoV-2 diagnostics for urgent clinical samples in the hospital setting.",
author = "Dominik N{\"o}rz and Nicole Fischer and Alexander Schultze and Stefan Kluge and Ulrich Mayer-Runge and Martin Aepfelbacher and Susanne Pfefferle and Marc L{\"u}tgehetmann",
note = "Copyright {\textcopyright} 2020 Elsevier B.V. All rights reserved.",
year = "2020",
month = jul,
doi = "10.1016/j.jcv.2020.104390",
language = "English",
volume = "128",
pages = "104390",
journal = "J CLIN VIROL",
issn = "1386-6532",
publisher = "Elsevier",

}

RIS

TY - JOUR

T1 - Clinical evaluation of a SARS-CoV-2 RT-PCR assay on a fully automated system for rapid on-demand testing in the hospital setting

AU - Nörz, Dominik

AU - Fischer, Nicole

AU - Schultze, Alexander

AU - Kluge, Stefan

AU - Mayer-Runge, Ulrich

AU - Aepfelbacher, Martin

AU - Pfefferle, Susanne

AU - Lütgehetmann, Marc

N1 - Copyright © 2020 Elsevier B.V. All rights reserved.

PY - 2020/7

Y1 - 2020/7

N2 - BACKGROUND: The ongoing SARS-CoV-2 pandemic presents a unique challenge for diagnostic laboratories around the world. Automation of workflows in molecular diagnostics is instrumental for coping with the large number of tests ordered by clinicians, as well as providing fast-tracked rapid testing for highly urgent cases. In this study we evaluated a SARS-CoV-2 LDT for the NeuMoDx 96 system, a fully automated device performing extraction and real-time PCR.METHODS: A publicly available SARS-CoV-2 RT-PCR assay was adapted for the automated system. Analytical performance was evaluated using in-vitro transcribed RNA and clinical performance was compared to the cobas 6800-based reference assay within the lab.RESULTS: The Envelope (E) Gene-LDT displayed good analytical performance with an LoD of 95.55 cp/mL and no false positives during evaluation of cross-reactivity. A total of 176 patient samples were tested with both the E-Gene-LDT and the reference assay. Positive and negative agreement were 100 % and 99.2 % respectively. Invalid-rate was 6.3 %.CONCLUSION: The E-Gene-LDT showed analytical and clinical performance comparable to the cobas6800-based reference assay. Due to its random-access workflow concept and rapid time-to-result of about 80 min, the system is very well suited for providing fast-tracked SARS-CoV-2 diagnostics for urgent clinical samples in the hospital setting.

AB - BACKGROUND: The ongoing SARS-CoV-2 pandemic presents a unique challenge for diagnostic laboratories around the world. Automation of workflows in molecular diagnostics is instrumental for coping with the large number of tests ordered by clinicians, as well as providing fast-tracked rapid testing for highly urgent cases. In this study we evaluated a SARS-CoV-2 LDT for the NeuMoDx 96 system, a fully automated device performing extraction and real-time PCR.METHODS: A publicly available SARS-CoV-2 RT-PCR assay was adapted for the automated system. Analytical performance was evaluated using in-vitro transcribed RNA and clinical performance was compared to the cobas 6800-based reference assay within the lab.RESULTS: The Envelope (E) Gene-LDT displayed good analytical performance with an LoD of 95.55 cp/mL and no false positives during evaluation of cross-reactivity. A total of 176 patient samples were tested with both the E-Gene-LDT and the reference assay. Positive and negative agreement were 100 % and 99.2 % respectively. Invalid-rate was 6.3 %.CONCLUSION: The E-Gene-LDT showed analytical and clinical performance comparable to the cobas6800-based reference assay. Due to its random-access workflow concept and rapid time-to-result of about 80 min, the system is very well suited for providing fast-tracked SARS-CoV-2 diagnostics for urgent clinical samples in the hospital setting.

U2 - 10.1016/j.jcv.2020.104390

DO - 10.1016/j.jcv.2020.104390

M3 - SCORING: Journal article

C2 - 32388471

VL - 128

SP - 104390

JO - J CLIN VIROL

JF - J CLIN VIROL

SN - 1386-6532

ER -