Bruch's Membrane Opening Minimum Rim Width Measurement with SD-OCT: A Method to Correct for the Opening Size of Bruch's Membrane

Standard

Bruch's Membrane Opening Minimum Rim Width Measurement with SD-OCT: A Method to Correct for the Opening Size of Bruch's Membrane. / Kromer, Robert; Spitzer, Martin Stephan.

in: J OPHTHALMOL, Jahrgang 2017, 2017, S. 8963267.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{c9257bdcb7bd4ad8a476a206582a1128,
title = "Bruch's Membrane Opening Minimum Rim Width Measurement with SD-OCT: A Method to Correct for the Opening Size of Bruch's Membrane",
abstract = "A precise evaluation of the retinal nerve fiber layer thickness (RNFLT) is key for diagnosing and monitoring glaucoma. The Bruch's membrane opening minimum rim width (BMO-MRW) has been proposed as a reproducible assessment of the optic nerve. The BMO-MRW measures the minimum distance from the BMO to the internal limiting membrane. We propose an approach to correct the BMO-MRW using the BMO size for increased accuracy in interindividual comparisons in future studies. Eighty-one healthy patients received SPECTRALIS spectral domain optical coherence tomography measurements for the peripapillary RNFLT and BMO-MRW. We calculated a BMO size-corrected BMO-MRW using the mean BMO size of our cohort. BMO size was defined using the manufacturer-provided BMO area and manually measured BMO perimeter. We observed that the BMO-MRW correlated highly with the perimeter (r = -0.553, p < 0.0001) and the area of the BMO (r = -0.546, p < 0.0001). Using these parameters, we provided a corrected BMO size-adjusted BMO-MRW which was better correlated with the RNFLT compared to the noncorrected one (z = -3.3495, p = 0.0004). We demonstrated the dependency of the BMO-MRW on ONH size. Furthermore, we showed the superiority of the corrected BMO-MRW using either the manually measured optic nerve head perimeter or the automatically provided ONH for future studies.",
keywords = "Journal Article",
author = "Robert Kromer and Spitzer, {Martin Stephan}",
year = "2017",
doi = "10.1155/2017/8963267",
language = "English",
volume = "2017",
pages = "8963267",
journal = "J OPHTHALMOL",
issn = "2090-004X",
publisher = "Hindawi Publishing Corporation",

}

RIS

TY - JOUR

T1 - Bruch's Membrane Opening Minimum Rim Width Measurement with SD-OCT: A Method to Correct for the Opening Size of Bruch's Membrane

AU - Kromer, Robert

AU - Spitzer, Martin Stephan

PY - 2017

Y1 - 2017

N2 - A precise evaluation of the retinal nerve fiber layer thickness (RNFLT) is key for diagnosing and monitoring glaucoma. The Bruch's membrane opening minimum rim width (BMO-MRW) has been proposed as a reproducible assessment of the optic nerve. The BMO-MRW measures the minimum distance from the BMO to the internal limiting membrane. We propose an approach to correct the BMO-MRW using the BMO size for increased accuracy in interindividual comparisons in future studies. Eighty-one healthy patients received SPECTRALIS spectral domain optical coherence tomography measurements for the peripapillary RNFLT and BMO-MRW. We calculated a BMO size-corrected BMO-MRW using the mean BMO size of our cohort. BMO size was defined using the manufacturer-provided BMO area and manually measured BMO perimeter. We observed that the BMO-MRW correlated highly with the perimeter (r = -0.553, p < 0.0001) and the area of the BMO (r = -0.546, p < 0.0001). Using these parameters, we provided a corrected BMO size-adjusted BMO-MRW which was better correlated with the RNFLT compared to the noncorrected one (z = -3.3495, p = 0.0004). We demonstrated the dependency of the BMO-MRW on ONH size. Furthermore, we showed the superiority of the corrected BMO-MRW using either the manually measured optic nerve head perimeter or the automatically provided ONH for future studies.

AB - A precise evaluation of the retinal nerve fiber layer thickness (RNFLT) is key for diagnosing and monitoring glaucoma. The Bruch's membrane opening minimum rim width (BMO-MRW) has been proposed as a reproducible assessment of the optic nerve. The BMO-MRW measures the minimum distance from the BMO to the internal limiting membrane. We propose an approach to correct the BMO-MRW using the BMO size for increased accuracy in interindividual comparisons in future studies. Eighty-one healthy patients received SPECTRALIS spectral domain optical coherence tomography measurements for the peripapillary RNFLT and BMO-MRW. We calculated a BMO size-corrected BMO-MRW using the mean BMO size of our cohort. BMO size was defined using the manufacturer-provided BMO area and manually measured BMO perimeter. We observed that the BMO-MRW correlated highly with the perimeter (r = -0.553, p < 0.0001) and the area of the BMO (r = -0.546, p < 0.0001). Using these parameters, we provided a corrected BMO size-adjusted BMO-MRW which was better correlated with the RNFLT compared to the noncorrected one (z = -3.3495, p = 0.0004). We demonstrated the dependency of the BMO-MRW on ONH size. Furthermore, we showed the superiority of the corrected BMO-MRW using either the manually measured optic nerve head perimeter or the automatically provided ONH for future studies.

KW - Journal Article

U2 - 10.1155/2017/8963267

DO - 10.1155/2017/8963267

M3 - SCORING: Journal article

C2 - 29119022

VL - 2017

SP - 8963267

JO - J OPHTHALMOL

JF - J OPHTHALMOL

SN - 2090-004X

ER -