Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures-a finite-element investigation

Standard

Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures-a finite-element investigation. / Dehoust, J; Münch, M; Seide, K; Barth, T; Frosch, K-H.

in: EUR J TRAUMA EMERG S, Jahrgang 46, Nr. 6, 12.2020, S. 1257-1266.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{852e8b60856c4552b9693fd2274d960a,
title = "Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures-a finite-element investigation",
abstract = "PURPOSE: To gain principal insight into fixation techniques of a posteromedial split fragment in bicondylar tibial plateau fractures.METHODS: A computer simulation was performed, applying the finite-element method (FEM) to compare four methods of fixation of the posteromedial split fragment: lateral plate (model 1), lateral plate and kickstand screw (model 2), lateral plate and two antero-posterior lag screws (model 3), and lateral and posteromedial plate (model 4). The displacement of the fragment and material stresses in implants and bone under 2500 N axial load were analyzed.RESULTS: Maximal displacement of the posteromedial split fragment of 2.8 mm was found with a sole lateral plate. An added kickstand screw decreased the displacement to 1.46 mm. Added lag screws improved stability by a factor 4, with a maximal displacement of 0.76 mm. The double-plate configuration revealed 0.27 mm, a decrease of the displacement by a factor 10 compared to model 1. An additional analysis of posteromedial fragment displacements with osteoporotic bone, simulated by dividing the elastic modulus of the bone by a factor 2, turned out to be of relevant impact. For model 1, the calculations did not converge. The influence of bone quality was found to be 70% in model 2, 60% in model 3, and 40% in model 4.CONCLUSIONS: The results indicate that the additional fixation of a posteromedial split fracture by plate osteosynthesis might be advantageous in bicondylar tibial plateau fractures treated with lateral plating. This might be even more important in patients with low bone quality.",
author = "J Dehoust and M M{\"u}nch and K Seide and T Barth and K-H Frosch",
year = "2020",
month = dec,
doi = "10.1007/s00068-020-01538-3",
language = "English",
volume = "46",
pages = "1257--1266",
journal = "EUR J TRAUMA EMERG S",
issn = "1863-9933",
publisher = "Urban und Vogel",
number = "6",

}

RIS

TY - JOUR

T1 - Biomechanical aspects of the posteromedial split in bicondylar tibial plateau fractures-a finite-element investigation

AU - Dehoust, J

AU - Münch, M

AU - Seide, K

AU - Barth, T

AU - Frosch, K-H

PY - 2020/12

Y1 - 2020/12

N2 - PURPOSE: To gain principal insight into fixation techniques of a posteromedial split fragment in bicondylar tibial plateau fractures.METHODS: A computer simulation was performed, applying the finite-element method (FEM) to compare four methods of fixation of the posteromedial split fragment: lateral plate (model 1), lateral plate and kickstand screw (model 2), lateral plate and two antero-posterior lag screws (model 3), and lateral and posteromedial plate (model 4). The displacement of the fragment and material stresses in implants and bone under 2500 N axial load were analyzed.RESULTS: Maximal displacement of the posteromedial split fragment of 2.8 mm was found with a sole lateral plate. An added kickstand screw decreased the displacement to 1.46 mm. Added lag screws improved stability by a factor 4, with a maximal displacement of 0.76 mm. The double-plate configuration revealed 0.27 mm, a decrease of the displacement by a factor 10 compared to model 1. An additional analysis of posteromedial fragment displacements with osteoporotic bone, simulated by dividing the elastic modulus of the bone by a factor 2, turned out to be of relevant impact. For model 1, the calculations did not converge. The influence of bone quality was found to be 70% in model 2, 60% in model 3, and 40% in model 4.CONCLUSIONS: The results indicate that the additional fixation of a posteromedial split fracture by plate osteosynthesis might be advantageous in bicondylar tibial plateau fractures treated with lateral plating. This might be even more important in patients with low bone quality.

AB - PURPOSE: To gain principal insight into fixation techniques of a posteromedial split fragment in bicondylar tibial plateau fractures.METHODS: A computer simulation was performed, applying the finite-element method (FEM) to compare four methods of fixation of the posteromedial split fragment: lateral plate (model 1), lateral plate and kickstand screw (model 2), lateral plate and two antero-posterior lag screws (model 3), and lateral and posteromedial plate (model 4). The displacement of the fragment and material stresses in implants and bone under 2500 N axial load were analyzed.RESULTS: Maximal displacement of the posteromedial split fragment of 2.8 mm was found with a sole lateral plate. An added kickstand screw decreased the displacement to 1.46 mm. Added lag screws improved stability by a factor 4, with a maximal displacement of 0.76 mm. The double-plate configuration revealed 0.27 mm, a decrease of the displacement by a factor 10 compared to model 1. An additional analysis of posteromedial fragment displacements with osteoporotic bone, simulated by dividing the elastic modulus of the bone by a factor 2, turned out to be of relevant impact. For model 1, the calculations did not converge. The influence of bone quality was found to be 70% in model 2, 60% in model 3, and 40% in model 4.CONCLUSIONS: The results indicate that the additional fixation of a posteromedial split fracture by plate osteosynthesis might be advantageous in bicondylar tibial plateau fractures treated with lateral plating. This might be even more important in patients with low bone quality.

U2 - 10.1007/s00068-020-01538-3

DO - 10.1007/s00068-020-01538-3

M3 - SCORING: Journal article

C2 - 33179130

VL - 46

SP - 1257

EP - 1266

JO - EUR J TRAUMA EMERG S

JF - EUR J TRAUMA EMERG S

SN - 1863-9933

IS - 6

ER -