Biomarker value and pitfalls of serum S100B in the follow-up of high-risk melanoma patients

Abstract

BACKGROUND AND OBJECTIVES: Serum levels of S100B are standard in monitoring advanced malignant melanoma patients in order to discriminate progressive from non-progressive disease. False-positive results lead to distress among patients and increase the amount of cost-intensive diagnostics. We therefore analyzed reported comorbid diseases as putative sources of excessive S100B release.

PATIENTS AND METHODS: Here, we report a single-center experience on serum S100B levels in 2,664 blood samples from 1,113 stage IB to IV melanoma patients (AJCC) who presented for follow-up examinations over a period of 24 months.

RESULTS: Overall, 295 (11%) of patients developed disease progression. In patients with a high tumor load, the rate of false-negative results was 30/185 (16%). The rate of false-positive results was 247/2369 (12%). One hundred and six false-positive results (69%) compared to 46 true-positive results (31%) were found in patients with cardiovascular diseases such as arrhythmia (50/32) or previous myocardial infarction (22/14). Moreover, obesity (85/14), liver cirrhosis (31/10), migraine (18/2), chronic kidney disease (13/2), and previous stroke (11/1) were found to be associated with false-positive S100B levels.

CONCLUSIONS: Serum S100B is a useful quantitative biomarker in routine follow-up of high-risk melanoma patients. While false-negative results are frequent in patients with low tumor load, false-positive results are associated with several comorbid diseases and warrant careful reevaluation.

Bibliografische Daten

OriginalspracheEnglisch
ISSN1610-0379
DOIs
StatusVeröffentlicht - 02.2016
PubMed 26819111