Bioequivalence comparison of a new freezing bag (CryoMACS(®)) with the Cryocyte(®) freezing bag for cryogenic storage of human hematopoietic progenitor cells.
Standard
Bioequivalence comparison of a new freezing bag (CryoMACS(®)) with the Cryocyte(®) freezing bag for cryogenic storage of human hematopoietic progenitor cells. / Sputtek, Andreas; Lioznov, Michael; Kröger, Nicolaus; Rowe, Arthur W.
in: CYTOTHERAPY, Jahrgang 13, Nr. 4, 4, 2011, S. 481-489.Publikationen: SCORING: Beitrag in Fachzeitschrift/Zeitung › SCORING: Zeitschriftenaufsatz › Forschung › Begutachtung
Harvard
APA
Vancouver
Bibtex
}
RIS
TY - JOUR
T1 - Bioequivalence comparison of a new freezing bag (CryoMACS(®)) with the Cryocyte(®) freezing bag for cryogenic storage of human hematopoietic progenitor cells.
AU - Sputtek, Andreas
AU - Lioznov, Michael
AU - Kröger, Nicolaus
AU - Rowe, Arthur W
PY - 2011
Y1 - 2011
N2 - Abstract Background aims. We investigated two different plastic freezing bags, namely the most recently U.S. Food and Drug Administration (FDA)-approved CryoMACS(®) freezing bag (200-074-402) from Miltenyi Biotec and the familiar Cryocyte(®) freezing bag (R4R9955) from (Baxter Healthcare, Deerfield, IL, United States) for the cryogenic storage of human hematopoietic progenitor cells (HPC). Methods. The study material consisted of 12 frozen HPC pairs (= 24 transplant units) that were no longer needed for autologous treatment of patients. After thawing, one unit of a pair was transferred into the Miltenyi (M) bag; the other unit remained in the original Baxter (B) bag. After refreezing both units, all units were stored again under cryogenic conditions either partially immersed in liquid nitrogen (n = 22) or in the vapor phase over liquid nitrogen, n = 2,
AB - Abstract Background aims. We investigated two different plastic freezing bags, namely the most recently U.S. Food and Drug Administration (FDA)-approved CryoMACS(®) freezing bag (200-074-402) from Miltenyi Biotec and the familiar Cryocyte(®) freezing bag (R4R9955) from (Baxter Healthcare, Deerfield, IL, United States) for the cryogenic storage of human hematopoietic progenitor cells (HPC). Methods. The study material consisted of 12 frozen HPC pairs (= 24 transplant units) that were no longer needed for autologous treatment of patients. After thawing, one unit of a pair was transferred into the Miltenyi (M) bag; the other unit remained in the original Baxter (B) bag. After refreezing both units, all units were stored again under cryogenic conditions either partially immersed in liquid nitrogen (n = 22) or in the vapor phase over liquid nitrogen, n = 2,
M3 - SCORING: Zeitschriftenaufsatz
VL - 13
SP - 481
EP - 489
JO - CYTOTHERAPY
JF - CYTOTHERAPY
SN - 1465-3249
IS - 4
M1 - 4
ER -