Bending resistance of prefabricated titanium posts following molten cast core attachment.

Standard

Bending resistance of prefabricated titanium posts following molten cast core attachment. / Pfeiffer, Peter; Nergiz, Ibrahim; Schmage, Petra; Platzer, Ursula.

in: OPER DENT, Jahrgang 29, Nr. 4, 4, 2004, S. 404-409.

Publikationen: SCORING: Beitrag in Fachzeitschrift/ZeitungSCORING: ZeitschriftenaufsatzForschungBegutachtung

Harvard

APA

Vancouver

Bibtex

@article{d6907790cfe248d683c7a6b83e90ca86,
title = "Bending resistance of prefabricated titanium posts following molten cast core attachment.",
abstract = "Posts and cores are used to restore endodontically treated teeth that have substantial loss of the coronal tooth structure. This in vitro study was designed to determine the mechanical properties of prefabricated titanium posts following attachment of their metal cores by molten casting (caston). Prefabricated tapered titanium posts (ER post-restoring system, Komet, Lemgo, Germany) in three diameter sizes (ISO 50, 90, 110) (n=9) were cast over with the metal cores of three different alloys (Au-Ag-Pt, Au-Pt-Pd, Co-Cr-Mo). Also, posts of each size were precision fit into the central core channels of the different cast metal cores to serve as control specimens. The 0.2% yield strengths (R0.2) of all specimens were tested on a universal testing machine. Statistical analyses of the results were carried out with an analysis of variance (ANOVA, one-way, two-way) and Bonferroni-Dunn's multiple comparisons post-hoc analysis for test groups (alpha=0.05). There was a significant decrease in yield strength (p0.05). Prefabricated titanium posts with metal cores cast over them showed inferior mechanical properties compared to precision-fit posts. These results indicate greater strength of the titanium posts when their cast cores were attached mechanically rather than by the molten casting method.",
author = "Peter Pfeiffer and Ibrahim Nergiz and Petra Schmage and Ursula Platzer",
year = "2004",
language = "Deutsch",
volume = "29",
pages = "404--409",
journal = "OPER DENT",
issn = "0361-7734",
publisher = "Indiana University School of Dentistry",
number = "4",

}

RIS

TY - JOUR

T1 - Bending resistance of prefabricated titanium posts following molten cast core attachment.

AU - Pfeiffer, Peter

AU - Nergiz, Ibrahim

AU - Schmage, Petra

AU - Platzer, Ursula

PY - 2004

Y1 - 2004

N2 - Posts and cores are used to restore endodontically treated teeth that have substantial loss of the coronal tooth structure. This in vitro study was designed to determine the mechanical properties of prefabricated titanium posts following attachment of their metal cores by molten casting (caston). Prefabricated tapered titanium posts (ER post-restoring system, Komet, Lemgo, Germany) in three diameter sizes (ISO 50, 90, 110) (n=9) were cast over with the metal cores of three different alloys (Au-Ag-Pt, Au-Pt-Pd, Co-Cr-Mo). Also, posts of each size were precision fit into the central core channels of the different cast metal cores to serve as control specimens. The 0.2% yield strengths (R0.2) of all specimens were tested on a universal testing machine. Statistical analyses of the results were carried out with an analysis of variance (ANOVA, one-way, two-way) and Bonferroni-Dunn's multiple comparisons post-hoc analysis for test groups (alpha=0.05). There was a significant decrease in yield strength (p0.05). Prefabricated titanium posts with metal cores cast over them showed inferior mechanical properties compared to precision-fit posts. These results indicate greater strength of the titanium posts when their cast cores were attached mechanically rather than by the molten casting method.

AB - Posts and cores are used to restore endodontically treated teeth that have substantial loss of the coronal tooth structure. This in vitro study was designed to determine the mechanical properties of prefabricated titanium posts following attachment of their metal cores by molten casting (caston). Prefabricated tapered titanium posts (ER post-restoring system, Komet, Lemgo, Germany) in three diameter sizes (ISO 50, 90, 110) (n=9) were cast over with the metal cores of three different alloys (Au-Ag-Pt, Au-Pt-Pd, Co-Cr-Mo). Also, posts of each size were precision fit into the central core channels of the different cast metal cores to serve as control specimens. The 0.2% yield strengths (R0.2) of all specimens were tested on a universal testing machine. Statistical analyses of the results were carried out with an analysis of variance (ANOVA, one-way, two-way) and Bonferroni-Dunn's multiple comparisons post-hoc analysis for test groups (alpha=0.05). There was a significant decrease in yield strength (p0.05). Prefabricated titanium posts with metal cores cast over them showed inferior mechanical properties compared to precision-fit posts. These results indicate greater strength of the titanium posts when their cast cores were attached mechanically rather than by the molten casting method.

M3 - SCORING: Zeitschriftenaufsatz

VL - 29

SP - 404

EP - 409

JO - OPER DENT

JF - OPER DENT

SN - 0361-7734

IS - 4

M1 - 4

ER -